The results of calorimetric studies of a histological preparation of a surgically excised Baker’s cyst are presented. The measurements were performed on a DSC 204 F1 Phoenix differential...
30 June 2020 in Journal of radiology and nuclear medicine
Objective. To determine the magnetic resonance imaging (MRI) morphological features of Baker’s cysts and to assess their correlation with the age of patients.Material and methods. The investigation was based on the assessment of MRI readings in 37 patients with Baker’s cysts; of them there were 29 (78.4%) women and 8 (21.6%) men. The mean age of the examinees was 60.3 years (25 to 82 years).Results. The mean dimensions of the cysts were measured. Their length, width, and height were 34 ± 2.1 mm, 5 ± 1.2 mm (range 4–31 mm), and 58 ± 2.9 mm, respectively. Their mean thickness was 0.7 mm. Intracystic chondral bodies were detected in 3 (7.5%) cases. These parameters were shown to be unrelated to age. It was found that all cysts were multi-chamber and an average of 6.8 chambers was detected. There was a weak, inversely proportional, statistically significant relationship between the age of the patients and the number of chambers in the cyst. The younger participants of the investigation exhibited no meniscal damage in an overwhelming case (57.1%); whereas complete and incomplete meniscal tears much more often occurred in older patients with Baker’s cysts (from 29 (78.4%) to 34 (91.9%) people, respectively).Conclusion. Degenerative bone and cartilage tissue changes in the joint increase with age, regardless of the cyst sizes.
Introduction The scientific literature database contains numerous studies comparing the efficacy of platelet-rich plasma (PRP) and hyaluronic acid (HA) preparations in knee osteoarthritis, but the results are contradictory due to methodological limitations and high heterogeneity of treatment protocols. Purpose To compare the data from scientific studies on the effectiveness of using PRP and medium molecular weight HA preparations in the treatment of patients with knee osteoarthritis. Materials and methods A search of randomized controlled trials was conducted in PubMed, Embase, and the Cochrane Library published in the period 2017–2024 using the following keywords: osteoarthritis, knee joint, intra-articular injections, platelet-rich plasma, hyaluronic acid, WOMAC, and meta-analysis. Studies that examined patients diagnosed with knee osteoarthritis of any severity who received intra-articular injections of PRP or HA and assessed pain using the WOMAC were reviewed. After rigorous selection, four studies with identical treatment protocols were included. Results The meta-analysis included 4 studies involving 333 patients (164 in the PRP group and 169 in the HA group). The mean WOMAC pain score at 6 months after the start of treatment was 4.52 (SD = 1.59) in the PRP group and 4.95 (SD = 2.07) in the HA group. The effect size of Hedges' g was 0.26 (95 % CI: –0.61 to 1.14; p = 0.336). Egger's test did not reveal a statistically significant publication bias ( p = 0.06). Discussion Our study revealed no significant differences between the use of PRP and HA, which contradicts several previous meta-analyses. This may be due to the use of more stringent inclusion criteria in our analysis and the evaluation of HA preparations with only medium molecular weight. Conclusion This meta-analysis was aimed to compare the effectiveness of using PRP and medium molecular weight HA in the treatment of patients with knee osteoarthritis and did not reveal statistically significant differences between the groups in severity of pain using the WOMAC system six months after the start of treatment, which indicates comparable effectiveness of these therapy methods.
In this work, the calibration of the temperature readings obtained with the help of infrared fibers was performed. Based on the data obtained, a model of a fiber pyrometer is proposed.
31 December 2017 in Journal of Experimental and Clinical Surgery
Actuality: Interstitial application of light energy to pathological tissues of small volume always raises concerns about the possible negative impact of excessive thermal effects on the surrounding unchanged structures. At the same time, insufficient thermal exposure does not allow achieving the desired result of manipulation. In particular, with a similar problem, there are surgeons performing laser-induced thermotherapy of cysts of different localization. Objective: Determine the time to reach the desired temperature required for the irreversible coagulation of the wall of the Baker cyst, depending on the power of the laser radiation and the volume of the intracystic fluid. Materials and methods: Several series of experiments were carried out in which different volumes of aqueous lidocaine solution were heated in disposable syringes by laser radiation fed along a flexible light-bearing fiber. Registration of infrared radiation from this system was performed by a portable thermal imager CONDTROL IR-CAM (Russia). The time for heating the syringe to 70 ° C was measured at different radiation powers. Results: In all series of experiments, a predetermined temperature of 70 ° C was achieved, providing instantaneous protein coagulation. Attention is drawn to the fact that the calculated time by the formula (ideal) in all cases is less, which can be explained by the effect of heat removal from the walls of syringes. The higher the power of laser radiation, the less the effect of heat removal on the heating rate of the aqueous solution, and, accordingly, the time to reach the set temperature. Conclusion. In the energy regimes and volumes of the aqueous solution studied, the optical fiber with end radiation emission is not capable of causing carbonization and damage to surrounding tissues. Accordingly, contactless perforation of the cyst wall by laser radiation with a wavelength of 1.47 μm is impossible. The obtained data testify to the advisability of calculating the energy to reach the set temperature and keeping it for a period sufficient for coagulation transformation of the more external layers of education
30 June 2018 in Journal of Experimental and Clinical Surgery
Relevance. The Baker's cyst is the most numerous group of benign neoplasms of the popliteal region. The anatomical feature of the location, the vagueness of the etiology and pathogenesis leads to the lack of a single point of view on the tactics of treating popliteal cysts. In modern medical technologies, the method of local laser hyperthermia is often used, when the denaturing of collagen forming the basis of a tissue or an organ is based on surgical treatment. Since this technique does not have direct thermal control over the course of manipulation, it becomes necessary to strictly dosage controlled photocoagulation. Objectives of the study: to determine the optimal energy and time parameters of direct contact laser action on the wall of the Baker cyst in the simulation of its exo-vivo photocoagulation. Materials and methods of research. In the experiment we used a wall sample of Baker's cyst, obtained as a result of open extirpation of the cyst. The material was divided into 5 roughly equal in size and mass fragments. The first of them, without any physical effects, was immediately placed in a 10% formalin solution. For all other parts of the preparation, laser irradiation was carried out in a stationary manner with a surface contact of the optical fiber with the synovial layer of the samples. The effect on the fragment was carried out in a constant mode of the light flux with a wavelength of 1.47 μm. Results. The macroscopic and microscopic transformations that occur in the tissues of the wall of the Baker cyst were studied, with an output power of 5 and 10 W. Two series of experiments were conducted lasting 5 and 10 seconds. On the surface of the synovial membrane of the wall of Baker's cyst, the effect in the form of point carbonation was observed in all samples subjected to laser treatment. When a microscopic study of a drug not exposed to laser radiation, the synovial membrane was only loosened. In the fragment subjected to the contact action of 10 W laser radiation for 10 seconds, the focus of necrosis of the synovium and surface layers of collagen structures without a perifocal cell reaction is histologically determined. In all other samples, after laser photocoagulation, a focal destruction of the synovial membrane with a pronounced interstitial edema was determined in the histological study. Focal fragmentation of the surface fibers was detected near the loose loose collagen layers. Conclusions.The effect of high-energy laser radiation of 1.47 μm on the wall of the Baker cyst in all series of experiments did not lead to its total coagulation necrosis even in the direct irradiation zone. Considering the duration of the cyst of the energy exposure of the irradiation sufficient for the destruction of the wall, and also the small area of exposure of the laser irradiation to the face lightguide, it is evident that a considerable amount of time will be required for complete coagulation of the formation.