Jiping Lu

Jiping Lu


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 November 2017 in Energies
Verified
Journal Article
Open access
PDF file
ZLZheng Li
Zheng Li
JLJiping Lu
Jiping Lu
YZYa Zhu
Ya Zhu
WJWang Jiang
Wang Jiang
A centralized grid-connected photovoltaic (PV) station is a widely adopted method of neutral grounding using resistance, which can potentially make pre-existing protection systems invalid and threaten the safety of power grids. Therefore, studying the fault characteristics of grid-connected PV systems and their impact on power-grid protection is of great importance. Based on an analysis of the grid structure of a grid-connected PV system and of the low-voltage ride-through control characteristics of a photovoltaic power supply, this paper proposes a short-circuit calculation model and a fault-calculation method for this kind of system. With respect to the change of system parameters, particularly the resistance connected to the neutral point, and the possible impact on protective actions, this paper achieves the general rule of short-circuit current characteristics through a simulation, which provides a reference for devising protection configurations.

4 August 2020 in IEEE Access
Verified
Journal Article
Open access
ZLZheng Li
Zheng Li
JLJiping Lu
Jiping Lu
JLJialin Liu
Jialin Liu
YZYa Zhu
Ya Zhu
QHQian He
Qian He
Neutral grounding through resistance is widely applied in large-scale centralized grid-connected photovoltaic power stations (PVPS), while protection measures, which are supposed to cut off the single-phase grounding fault of the collection system quickly, are required according to the grid code. Analyses on the coordination between protection performances and low voltage ride through (LVRT) are missing in current researches. Hence there could be a risk that large-scale photovoltaic units may disconnect from the grid as a result of a mismatch between the protection and LVRT. In view of the above, this paper makes contributions in two aspects. Firstly, this paper proposes a scheme on neutral point resistance selection, which is to analyze the influences on protection performances by the fault characteristics of the single-phase grounding fault of the PVPS collection system in different test environments, and then to quantify the speed and the selectivity of the zero-sequence current protection performance as assessment indexes, as required in the coordination between protection performances and LVRT, and in the coordination between protection performances of tie lines and collector lines of the collection system, and finally to select neutral point resistance based on the indexes. Secondly, this paper proposes a comprehensive control strategy on the large-scale PVPS, which can effectively improve the assessment indexes mentioned above of the protection under different active power production scenarios. Finally, a simulation will be conducted to verify the correctness and the feasibility of the resistance selection scheme and the control strategy proposed in this paper.

5 October 2017 in Energies
Verified
Journal Article
Open access
PDF file
SZSanli Zhu
Sanli Zhu
JLJiping Lu
Jiping Lu
ZLZheng Li
Zheng Li
JLJunyi Lin
Junyi Lin
To improve the controllability of the electric power output and the economic performance of a large-scale wind farm, an auxiliary energy storage system is required. This paper deals with the rule of planning reasonable energy storage power and capacity based on the historical annual mean wind speed data, the probability density of the pulsating wind power output, and the warranted firm power provided by the wind farm. Specifically, the evaluation index of the fluctuation degree of the firm power is defined in order to optimize the planned energy storage capacity. After that, the firm power escalation affected by the energy storage power and the conversion rate of the storage device are quantitatively evaluated. All of these analyses contribute in a significant way towards determining the acceptable energy conversion rate with the condition of limited energy storage space of a wind-storage hybrid power system. The proposed evaluation method of the firm power escalation is verified by MatLab simulation results.