Markus Wallner

Prof. Dr. Markus Wallner


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2024 in Journal of Water and Health
Verified
Journal Article
Open access
UDUrda Düker
Urda Düker
RNRegina Nogueira
Regina Nogueira
ECEstefania Carpio-Vallejo
Estefania Carpio-Vallejo
IJIngeborg Joost
Ingeborg Joost
KHKatharina Hüppe
Katharina Hüppe
MWMarkus Wallner
Markus Wallner
Wastewater treatment plant (WWTP) influent sampling is commonly used in wastewater-based disease surveillance to assess the circulation of pathogens in the population aggregated in a catchment area. However, the signal can be lost within the sewer network due to adsorption, degradation, and dilution processes. The present work aimed to investigate the dynamics of SARS-CoV-2 concentration in three sub-catchments of the sewer system in the city of Hildesheim, Germany, characterised by different levels of urbanisation and presence/absence of industry, and to evaluate the benefit of sub-catchment sampling compared to WWTP influent sampling. Our study shows that sampling and analysis of virus concentrations in sub-catchments with particular settlement structures allows the identification of high concentrations of the virus at a local level in the wastewater, which are lower in samples collected at the inlet of the treatment plant covering the whole catchment. Higher virus concentrations per inhabitant were found in the sub-catchments in comparison to the inlet of the WWTP. Additionally, sewer sampling provides spatially resolved concentrations of SARS-CoV-2 in the catchment area, which is important for detecting local high incidences of COVID-19.

5 March 2026 in Eng
Verified
Journal Article
Open access
PDF file
YYYao Yao
Yao Yao
MWMarkus Wallner
Markus Wallner
Frank KlawonnFrank Klawonn
Frank Klawonn
The optimal placement of samplers and sensors in water distribution systems (WDSs) and wastewater collection systems (WCSs) is fundamental to effective monitoring, early contamination detection, and system protection. The goal of optimal sensor/sampling placement (OSP) is to maximize the ability to detect, monitor, and track critical variables, such as contaminants or temperature, while maintaining cost-effectiveness and operational efficiency. In practice, OSP problems are inherently multi-objective and typically involve trade-offs between cost minimization, spatial and temporal coverage, detection accuracy, and robustness under uncertainty. This paper presents a comprehensive review of recent single- and multi-objective optimization strategies for source detection and monitoring, drawing on approaches developed in various research fields. The reviewed literature is systematically organized according to problem formulation, objective functions, optimization techniques, and decision-making strategies, paying particular attention to their applicability in real-world WDSs and WCSs. Beyond summarizing existing methods, this review critically examines key methodological assumptions and limitations that hinder practical implementation. These include sparse sensor deployment, budget constraints, and modeling and sensor uncertainty. Finally, the paper identifies open challenges and outlines potential directions for future research aimed at improving the robustness, scalability, and practical relevance of OSP strategies.


4 September 2026
Verified
Other
Open access
YYYao Yao
Yao Yao
LTLuisa-Bianca Thiele
Luisa-Bianca Thiele
MSMohammad Sarailoo
Mohammad Sarailoo
FKFrank Klawonn
Frank Klawonn
RNRegina Nogueira
Regina Nogueira
MWMarkus Wallner
Markus Wallner
Urbanization and climate variability increasingly intensify hydrological extremes that impair water quality. A critical compound stress arises when pollutant-rich urban runoff coincides with limited river dilution capacity. To characterize this interaction, we analyze compound events in two directional modes: (i) low river flow paired with corresponding urban runoff, and (ii) high urban runoff paired with concurrent river flow. While these modes represent distinct pathways leading to loss of dilution capacity, the underlying variables exhibit weak and inconsistent dependence, limiting the applicability of conventional bivariate extreme value approaches. To address this limitation, we introduce the Urban-Runoff-to-River-Flow ratio as a direct indicator of dilution stress. A ratio-based extreme value framework is developed using both block maxima and peak-over-threshold approaches, with parameters estimated via maximum likelihood and L-moment methods. The analysis is based on more than two decades of discharge data from three catchments in Lower Saxony, Germany, representing contrasting hydrological regimes. Model performance and compound risk estimates are evaluated against two reference benchmarks: (i) a synthetic benchmark derived from marginal extremes under independence assumptions, and (ii) a conditional benchmark based on historically co-occurring events. Results show that conditional approaches systematically underestimate compound risk in weakly dependent systems, while synthetic estimates provide an upper bound by enforcing coincidence of extremes. In contrast, the ratio-based approach captures the interaction between pollutant loading and dilution capacity more consistently across sites. Overall, the proposed framework provides a robust and physically interpretable method for assessing compound dilution stress, particularly in systems where dependence between drivers is weak or unstable.

9 October 2026
Verified
Other
Open access
YYYao Yao
Yao Yao
LTLuisa-Bianca Thiele
Luisa-Bianca Thiele
MSMohammad Sarailoo
Mohammad Sarailoo
FKFrank Klawonn
Frank Klawonn
RNRegina Nogueira
Regina Nogueira
MWMarkus Wallner
Markus Wallner
Urbanization and climate variability increasingly intensify hydrological extremes that impair water quality. A critical compound stress arises when pollutant-rich urban runoff coincides with limited river dilution capacity. To characterize this interaction, we analyze compound events in two directional modes: (i) low river flow paired with corresponding urban runoff, and (ii) high urban runoff paired with concurrent river flow. While these modes represent distinct pathways leading to loss of dilution capacity, the underlying variables exhibit weak and inconsistent dependence, limiting the applicability of conventional bivariate extreme value approaches. To address this limitation, we introduce the Urban-Runoff-to-River-Flow ratio as a direct indicator of dilution stress. A ratio-based extreme value framework is developed using both block maxima and peak-over-threshold approaches, with parameters estimated via maximum likelihood and L-moment methods. The analysis is based on more than two decades of discharge data from three catchments in Lower Saxony, Germany, representing contrasting hydrological regimes. Model performance and compound risk estimates are evaluated against two reference benchmarks: (i) a synthetic benchmark derived from marginal extremes under independence assumptions, and (ii) a conditional benchmark based on historically co-occurring events. Results show that conditional approaches systematically underestimate compound risk in weakly dependent systems, while synthetic estimates provide an upper bound by enforcing coincidence of extremes. In contrast, the ratio-based approach captures the interaction between pollutant loading and dilution capacity more consistently across sites. Overall, the proposed framework provides a robust and physically interpretable method for assessing compound dilution stress, particularly in systems where dependence between drivers is weak or unstable.

9 October 2026
Verified
Other
Open access
YYYao Yao
Yao Yao
LTLuisa-Bianca Thiele
Luisa-Bianca Thiele
MSMohammad Sarailoo
Mohammad Sarailoo
FKFrank Klawonn
Frank Klawonn
RNRegina Nogueira
Regina Nogueira
MWMarkus Wallner
Markus Wallner
Urbanization and climate variability increasingly intensify hydrological extremes that impair water quality. A critical compound stress arises when pollutant-rich urban runoff coincides with limited river dilution capacity. To characterize this interaction, we analyze compound events in two directional modes: (i) low river flow paired with corresponding urban runoff, and (ii) high urban runoff paired with concurrent river flow. While these modes represent distinct pathways leading to loss of dilution capacity, the underlying variables exhibit weak and inconsistent dependence, limiting the applicability of conventional bivariate extreme value approaches. To address this limitation, we introduce the Urban-Runoff-to-River-Flow ratio as a direct indicator of dilution stress. A ratio-based extreme value framework is developed using both block maxima and peak-over-threshold approaches, with parameters estimated via maximum likelihood and L-moment methods. The analysis is based on more than two decades of discharge data from three catchments in Lower Saxony, Germany, representing contrasting hydrological regimes. Model performance and compound risk estimates are evaluated against two reference benchmarks: (i) a synthetic benchmark derived from marginal extremes under independence assumptions, and (ii) a conditional benchmark based on historically co-occurring events. Results show that conditional approaches systematically underestimate compound risk in weakly dependent systems, while synthetic estimates provide an upper bound by enforcing coincidence of extremes. In contrast, the ratio-based approach captures the interaction between pollutant loading and dilution capacity more consistently across sites. Overall, the proposed framework provides a robust and physically interpretable method for assessing compound dilution stress, particularly in systems where dependence between drivers is weak or unstable.