Detection and control of infectious diseases is a major problem, especially in developing countries. Lateral flow immunoassays can be used with great success for the detection of infectious diseases. However, for the quantification of their results an electronic reader is required. This paper presents an optimized handheld electronic reader for developing countries. It features a potentially low-cost, low-power, battery-operated device with no added optical accessories. The operation of this proof of concept device is based on measuring the reflected light from the lateral flow immunoassay and translating it into the concentration of the specific analyte of interest. Characterization of the surface of the lateral flow immunoassay has been performed in order to accurately model its response to the incident light. Ray trace simulations have been performed to optimize the system and achieve maximum sensitivity by placing all the components in optimum positions. A microcontroller enables all the signal processing to be performed on the device and a Bluetooth module allows transmission of the results wirelessly to a mobile phone app. Its performance has been validated using lateral flow immunoassays with influenza A nucleoprotein in the concentration range of 0.5 ng/mL to 200 ng/mL.
27 September 2019 in IEEE Transactions on Circuits and Systems II: Express Briefs
Wireless biosensors are playing a pivotal role in health monitoring, disease detection and management. The development of wireless biosensor nodes and networks strongly relies on the design of novel low-power, low-cost and flexible CMOS sensor readouts. This paper presents a CMOS potentiostat that integrates a control amplifier, a dual-slope ADC and a wireless unit on the same chip. It implements a novel time-based readout scheme, whereby the counter of the dual-slope ADC is moved to the receiver and the sensor current is encoded in the timing between two wireless pulses transmitted via pulse-harmonic modulation across an inductive link. Measured results show that the potentiostat chip can resolve a minimum input current of 10pA at a sampling frequency of 125 Hz and a power consumption of 12 μW.
13 July 2018 in IEEE Transactions on Circuits and Systems II: Express Briefs
Point-of-care (POC) systems for the detection of infectious diseases are in great demand especially in developing countries. Lateral flow immunoassays are considered ideal biosensors for POC diagnostics due to their numerous advantages. However, to quantify their results a low power, robust electronic reader is needed. A low power CMOS image sensor is presented that can be used in quantitative lateral flow immunoassay readers. It uses a single low power processing capacitive transimpedance amplifier architecture which includes noise cancellation. A chip containing $4\times 64$ pixels was fabricated in CMOS 0.35- $\mu\text{m}$ technology. With uniform illumination at 525 nm and 67 frames/s the chip has 1.9 mV rms total output referred noise and a total power consumption of 21 $\mu\text{W}$ . In tests with lateral flow immunoassays the chip detected concentrations of influenza A nucleoprotein from 0.5 ng/mL to 200 ng/mL.
Wireless biosensors are playing a pivotal role in health monitoring, disease detection and management. The development of wireless biosensor nodes and networks strongly relies on the design of novel low-power, low-cost and flexible CMOS sensor readouts. This paper presents a CMOS potentiostat that integrates a control amplifier, a dual-slope ADC and a wireless unit on the same chip. It implements a novel time-based readout scheme, whereby the counter of the dual-slope ADC is moved to the receiver and the sensor current is encoded in the timing between two wireless pulses transmitted via pulse-harmonic modulation across an inductive link. Measured results show that the potentiostat chip can resolve a minimum input current of 10 pA at a sampling frequency of 125 Hz and a power consumption of 12 uW.