Leonardo Geronzi

Dr. Leonardo Geronzi

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2023 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
LGLeonardo Geronzi
Leonardo Geronzi
AMAntonio Martinez
Antonio Martinez
MRMichel Rochette
Michel Rochette
KYKexin Yan
Kexin Yan
ABAline Bel-Brunon
Aline Bel-Brunon
MBMarco Evangelos Biancolini
Marco Evangelos Biancolini

6 March 2023 in Frontiers in Physiology
Verified
Journal Article
Open access
LGLeonardo Geronzi
Leonardo Geronzi
PHPascal Haigron
Pascal Haigron
AMAntonio Martinez
Antonio Martinez
KYKexin Yan
Kexin Yan
MRMichel Rochette
Michel Rochette
MBMarco Evangelos Biancolini
Marco Evangelos Biancolini
The current guidelines for the ascending aortic aneurysm (AsAA) treatment recommend surgery mainly according to the maximum diameter assessment. This criterion has already proven to be often inefficient in identifying patients at high risk of aneurysm growth and rupture. In this study, we propose a method to compute a set of local shape features that, in addition to the maximum diameter D, are intended to improve the classification performances for the ascending aortic aneurysm growth risk assessment. Apart from D, these are the ratio DCR between D and the length of the ascending aorta centerline, the ratio EILR between the length of the external and the internal lines and the tortuosity T. 50 patients with two 3D acquisitions at least 6 months apart were segmented and the growth rate (GR) with the shape features related to the first exam computed. The correlation between them has been investigated. After, the dataset was divided into two classes according to the growth rate value. We used six different classifiers with input data exclusively from the first exam to predict the class to which each patient belonged. A first classification was performed using only D and a second with all the shape features together. The performances have been evaluated by computing accuracy, sensitivity, specificity, area under the receiver operating characteristic curve (AUROC) and positive (negative) likelihood ratio LHR+ (LHR−). A positive correlation was observed between growth rate and DCR (r = 0.511, p = 1.3e-4) and between GR and EILR (r = 0.472, p = 2.7e-4). Overall, the classifiers based on the four metrics outperformed the same ones based only on D. Among the diameter-based classifiers, k-nearest neighbours (KNN) reported the best accuracy (86%), sensitivity (55.6%), AUROC (0.74), LHR+ (7.62) and LHR− (0.48). Concerning the classifiers based on the four shape features, we obtained the best accuracy (94%), sensitivity (66.7%), specificity (100%), AUROC (0.94), LHR+ (+∞) and LHR− (0.33) with support vector machine (SVM). This demonstrates how automatic shape features detection combined with risk classification criteria could be crucial in planning the follow-up of patients with ascending aortic aneurysm and in predicting the possible dangerous progression of the disease.

30 June 2023 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
LGLeonardo Geronzi
Leonardo Geronzi
ABAline Bel-Brunon
Aline Bel-Brunon
AMAntonio Martinez
Antonio Martinez
MRMichel Rochette
Michel Rochette
MSMarco Sensale
Marco Sensale
MBMarco Evangelos Biancolini
Marco Evangelos Biancolini
Objective: we propose a procedure for calibrating 4 parameters governing the mechanical boundary conditions (BCs) of a thoracic aorta (TA) model derived from one patient with ascending aortic aneurysm. The BCs reproduce the visco-elastic structural support provided by the soft tissue and the spine and allow for the inclusion of the heart motion effect. Methods: we first segment the TA from magnetic resonance imaging (MRI) angiography and derive the heart motion by tracking the aortic annulus from cine-MRI. A rigid-wall fluid-dynamic simulation is performed to derive the time-varying wall pressure field. We build the finite element model considering patient-specific material properties and imposing the derived pressure field and the motion at the annulus boundary. The calibration, which involves the zero-pressure state computation, is based on purely structural simulations. After obtaining the vessel boundaries from the cine-MRI sequences, an iterative procedure is performed to minimize the distance between them and the corresponding boundaries derived from the deformed structural model. A strongly-coupled fluid-structure interaction (FSI) analysis is finally performed with the tuned parameters and compared to the purely structural simulation. Results and Conclusion: the calibration with structural simulations allows to reduce maximum and mean distances between image-derived and simulation-derived boundaries from 8.64 mm to 6.37 mm and from 2.24 mm to 1.83 mm, respectively. The maximum root mean square error between the deformed structural and FSI surface meshes is 0.19 mm. This procedure may prove crucial for increasing the model fidelity in replicating the real aortic root kinematics.

18 January 2024 in Fluids
Verified
Journal Article
Open access
PDF file
LGLeonardo Geronzi
Leonardo Geronzi
BFBenigno Marco Fanni
Benigno Marco Fanni
BJBart De Jong
Bart De Jong
GRGerben Roest
Gerben Roest
SKSasa Kenjeres
Sasa Kenjeres
MBMarco Evangelos Biancolini
Marco Evangelos Biancolini
The treatment for asthma and chronic obstructive pulmonary disease relies on forced inhalation of drug particles. Their distribution is essential for maximizing the outcomes. Patient-specific computational fluid dynamics (CFD) simulations can be used to optimize these therapies. In this regard, this study focuses on creating a parametric model of the human respiratory tract from which synthetic anatomies for particle deposition analysis through CFD simulation could be derived. A baseline geometry up to the fourth generation of bronchioles was extracted from a CT dataset. Radial basis function (RBF) mesh morphing acting on a dedicated tree structure was used to modify this baseline mesh, extracting 1000 synthetic anatomies. A total of 26 geometrical parameters affecting branch lengths, angles, and diameters were controlled. Morphed models underwent CFD simulations to analyze airflow and particle dynamics. Mesh morphing was crucial in generating high-quality computational grids, with 96% of the synthetic database being immediately suitable for accurate CFD simulations. Variations in wall shear stress, particle accretion rate, and turbulent kinetic energy across different anatomies highlighted the impact of the anatomical shape on drug delivery and deposition. The study successfully demonstrates the potential of tree-structure-based RBF mesh morphing in generating parametric airways for drug delivery studies.

6 January 2025 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Closed access
PDF file
KYKexin Yan
Kexin Yan
WYWenfeng Ye
Wenfeng Ye
AMAntonio Martínez
Antonio Martínez
LGLeonardo Geronzi
Leonardo Geronzi
PEPierre Escrig
Pierre Escrig
ABAline Bel-Brunon
Aline Bel-Brunon

4 March 2025 in arXiv
Verified
Preprint
Open access
PDF file
LGLeonardo Geronzi
Leonardo Geronzi
ABAline Bel-Brunon
Aline Bel-Brunon
AMAntonio Martinez
Antonio Martinez
MRMichel Rochette
Michel Rochette
MSMarco Sensale
Marco Sensale
MBMarco Evangelos Biancolini
Marco Evangelos Biancolini
Objective: we propose a procedure for calibrating 4 parameters governing the mechanical boundary conditions (BCs) of a thoracic aorta (TA) model derived from one patient with ascending aortic aneurysm. The BCs reproduce the visco-elastic structural support provided by the soft tissue and the spine and allow for the inclusion of the heart motion effect. Methods: we first segment the TA from magnetic resonance imaging (MRI) angiography and derive the heart motion by tracking the aortic annulus from cine-MRI. A rigid-wall fluid-dynamic simulation is performed to derive the time-varying wall pressure field. We build the finite element model considering patient-specific material properties and imposing the derived pressure field and the motion at the annulus boundary. The calibration, which involves the zero-pressure state computation, is based on purely structural simulations. After obtaining the vessel boundaries from the cine-MRI sequences, an iterative procedure is performed to minimize the distance between them and the corresponding boundaries derived from the deformed structural model. A strongly-coupled fluid-structure interaction (FSI) analysis is finally performed with the tuned parameters and compared to the purely structural simulation. Results and Conclusion: the calibration with structural simulations allows to reduce maximum and mean distances between image-derived and simulation-derived boundaries from 8.64 mm to 6.37 mm and from 2.24 mm to 1.83 mm, respectively. The maximum root mean square error between the deformed structural and FSI surface meshes is 0.19 mm. This procedure may prove crucial for increasing the model fidelity in replicating the real aortic root kinematics.