Fatih Mehmet ÖZKAL

Prof. Dr. Fatih Mehmet ÖZKAL

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in Construction and Building Materials
Verified
Journal Article
Closed access
FÖFatih Mehmet ÖZKAL
Fatih Mehmet ÖZKAL
MPMehmet Polat
Mehmet Polat
MYMahmud Yağan
Mahmud Yağan
MÖMuhammed Orhan Öztürk
Muhammed Orhan Öztürk

20 July 2022 in ACS Omega
Verified
Journal Article
Open access
BABetül Aliş
Betül Aliş
CYCasim Yazici
Casim Yazici
FÖFatih Mehmet ÖZKAL
Fatih Mehmet ÖZKAL
Structural deterioration during fire leads to significant economic losses, severe injuries, and deaths. Research to accurately estimate the impact of fire on structural security and performance, and to identify ways to reduce it, has been increasing recently with capital investments in the building and infrastructure sectors. This research aims to establish a reliable algorithm for simulating the behavior of reinforced concrete (RC) beams under thermal and structural loads. The proposed algorithm is based on the combination of thermal and structural analyses using the sequential link technique. These analyses use material characteristics such as conductivity, specific heat, stress-strain relationship, and thermal expansion to capture thermal and structural responses during the heating phases according to Eurocode 1 and Eurocode 2 using the finite element method. Beam models in the study, which have been exposed to the ISO-834 fire curve, were designed to exhibit flexural failure. Nonlinear numerical analysis results have mostly coincided with the previous studies regarding the residual load-bearing capacity. Depending on the outcomes of the previous experimental studies, an RC member's structural strength increases when the internal temperature is between 150 and 250 °C and degradation starts after 300 °C. This outcome has been supported by the previous numerical and experimental studies, propounding the accuracy of preferred modeling and analysis approaches. As the essential distinctness of the research, the effects of elevated temperatures on the bonding behavior between concrete and rebar were considered for numerical analyses.

20 July 2018 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Closed access
PDF file
ESErsin Sensoz
Ersin Sensoz
FÖFatih Mehmet ÖZKAL
Fatih Mehmet ÖZKAL
VAVolkan Acar
Volkan Acar
FCFerit Cakir
Ferit Cakir
Iatrogenic subtrochanteric fractures are rarely encountered after cannulated screw fixation of femoral neck fractures; however, when they do occur, there can be several complications. Many orthopedic surgeons have concerns about the potential for iatrogenic subtrochanteric fractures after screw fixation distal to the trochanter minor; therefore, some surgeons are typically reluctant to perform this procedure. This study focused on the risk of an iatrogenic subtrochanteric fracture after treating femoral neck fractures with cannulated screws. The main purpose of the study was to understand iatrogenic subtrochanteric fractures and evaluate the effects on these fractures of an inverted triangular–shaped configuration for placement of the cannulated screws. A femur bone with an femoral neck fracture at a 40° incline to the horizontal plane was generated along with a representation of a three-dimensional finite element model, and three inverted triangular–shaped configurations for placement of the cannulated screws were investigated using finite element analyses. Statistical results indicated that the occurrence risk of ISF increases when the screw is located distal to the trochanter minor. Moreover, the risk of occurrence of intertrochanteric fracture increases when the screw is located medial to the trochanter minor because of local concentrated stress on the surface of the screw canals. To avoid the vulnerability of the subtrochanteric region, it was found that proximal placement of the screws using the inverted triangular–shaped configuration could yield better results. In addition, the results of this study provide suggestions on improved screw configurations.

7 November 2022 in ACS Omega
Verified
Journal Article
Open access
CYCasim Yazıcı
Casim Yazıcı
FÖFatih Mehmet ÖZKAL
Fatih Mehmet ÖZKAL
SOSuleyman Nazif Orhan
Suleyman Nazif Orhan
BCBurak Kaan Cirpici
Burak Kaan Cirpici
Intumescent fire-resistive coatings are a more recent type of passive fireproofing thin film that swells many times its initial applied thickness, generating an insulating char that functions as a thermal barrier between the fire and structural steel. It keeps the heat of steel members from reaching critical levels and aids in the structural integrity during a fire. They are architects and designers' favorite choice for passive fire protection of load-bearing steel frame structures because of their aesthetic look, versatility, rapidity of application, and ease of inspection and maintenance. In this study, axial tensile, thermal conductivity, and hardness tests have been performed on S235 cold-formed steel specimens that were exposed to increasing temperature periods. The mechanical behavior of coated and uncoated specimens was investigated over the modulus of elasticity, yield strength/strain, and ultimate strength/strain values for all temperatures. As a result of the research, gradually increasing changes were observed in the mechanical properties of coated and uncoated specimens at increasing temperature levels, compared to each other. However, performance increment on the coated specimens was limited in terms of strength and strain characteristics than expected. Two essential reasons for this conclusion are that the specimens were exposed to heat for a long time after reaching the target temperature and also that the wall thickness of the specimens was thinner with respect to the usual application method of the protective coating. In order to examine the structural properties of the test specimens after elevated temperature effects, thermal conductivity measurement was also performed. Temperature difference between coated and uncoated surfaces provided a benefit in the range of 29-56% due to the coating. Lastly, microstructure imaging techniques demonstrated grain coarsening and no crack development with the increase in temperature.

28 September 2022 in ACS Omega
Verified
Journal Article
Open access
BCBurak Kaan Cirpici
Burak Kaan Cirpici
SOSuleyman Nazif Orhan
Suleyman Nazif Orhan
CYCasim Yazıcı
Casim Yazıcı
FÖFatih Mehmet ÖZKAL
Fatih Mehmet ÖZKAL

14 February 2024 in ACS Omega
Verified
Journal Article
Open access
MYMahmud Yağan
Mahmud Yağan
FÖFatih Mehmet ÖZKAL
Fatih Mehmet ÖZKAL
MÖMuhammed Orhan Öztürk
Muhammed Orhan Öztürk
MPMehmet Polat
Mehmet Polat
Reinforced concrete structures encounter a range of detrimental external factors over their operational lifespan. One of them is the elevated temperature effect due to fires. Conversely, due to the influence of global warming, temperatures are on the rise worldwide, leading to an increase in fire incidents. Owing to the increasing rates of construction and fire incidents, it becomes imperative to investigate the durability of reinforced concrete members when exposed to high temperatures. This experimental study aims to assess the structural behavior of reinforced concrete beams following exposure to elevated temperatures. To accomplish this goal, concrete cube specimens, steel rebars, pull-out specimens, and reinforced concrete beams were exposed to elevated temperatures of up to 800 °C and then allowed to cool in air. Following this, all specimens were subjected to testing in accordance with the relevant codes and standards. Test results were analyzed through comparison. In a comprehensive examination of the results, it is evident that the concrete compressive strength experiences an approximately 55% reduction at 600 °C. Meanwhile, there is no notable decrease in the yield strength of the steel at this temperature. However, at 800 °C, steel yield strength decreases by nearly 30%, while the compressive strength of the concrete decreases by a significant 82%. This indicates a substantial reduction in the load-bearing capacity of the beam specimens due to concrete deterioration and the subsequent decline in the bonding performance between concrete and steel rebars.