Simon Matthew Iveson

Dr. Simon Matthew Iveson

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2014 in International Journal of Coal Preparation and Utilization
Verified
Journal Article
Closed access
SISimon Matthew Iveson
Simon Matthew Iveson
MMM. Mason
M. Mason
KGKevin Galvin
Kevin Galvin
Two pilot-scale Reflux Classifiers (600 mm × 600 mm cross-section) arranged in a cascading sequence were used to beneficiate fine -2 mm coal. The first Reflux Classifier performed a density separation that produced a coal product contaminated with fine high-ash slimes. This was then washed in the second Reflux Classifier to remove the fine clays and mineral matter. This combination reliably produced a clean coal product and allowed gravity separation performance to be extended from the usual eight-fold limit of upper to lower size to a much broader size range. Performance was similar to previous laboratory-scale results units with cross-sectional areas of only 100 mm × 80 mm each. Hence, full-scale desliming units can be confidently designed based on laboratory trials. The cut size varied linearly from 0.04 to 0.24 mm with increases in the overflow channel velocity from 25 to 55 m3/(m2 h). The Ep values increased from 0.02 to 0.07 mm (Whitten factor α from 2 to 6) over the same range. The linear dependence of the cut size on velocity in the Reflux Classifier was consistent with the theory and with the significant throughput advantage of the technology.

1 August 2018 in Minerals Engineering
Verified
Journal Article
Closed access
KGK.P. Galvin
K.P. Galvin
SISimon Matthew Iveson
Simon Matthew Iveson
DHD.M. Hunter
D.M. Hunter


1 October 2018 in Minerals Engineering
Verified
Journal Article
Closed access
DKD. Kumar
D. Kumar
SISimon Matthew Iveson
Simon Matthew Iveson
KGKevin Galvin
Kevin Galvin

1 August 2019 in International Journal of Coal Preparation and Utilization
Verified
Journal Article
Closed access
SISimon Matthew Iveson
Simon Matthew Iveson
APA. Price
A. Price
KGK. P. Galvin
K. P. Galvin
A 2 m diameter REFLUX™ Classifier was tested on coal feeds up to 6 mm top size. Solids feed rate was varied from 50 to 160 t/h at suspension concentrations up to 37 wt.% solids. Performance was consistent, with product ashes below 10 wt.% for +1 mm particles and reject ashes usually exceeding 70 wt.%. The density cut point could be freely varied and decreased with particle size to the power −0.114. Ep values less than 0.10 were obtained on the composite +0.5 mm material. Ep varied with particle size to the power −0.963. Hence, beneficiation performance for −4.0 + 0.50 mm material approached that of large dense medium cyclones (DMCs). Hence, REFLUX™ Classifiers could be used to increase the capacity of existing plants with minimal capital expenditure. The primary screen aperture size could be raised to around 4 mm, which should significantly increase screen capacity. The +4.0 mm fraction could be sent to the existing DMC circuit, which with a lower fines loading would have increased capacity and medium recovery. The −4.0 mm fraction could be sent to a REFLUX™ Classifier and if required its overflow could then be sent to a flotation circuit.

14 February 2024 in Minerals
Verified
Journal Article
Open access
PDF file
SISimon Matthew Iveson
Simon Matthew Iveson
Nicolas BoonzaierNicolas Boonzaier
Nicolas Boonzaier
KGKevin Galvin
Kevin Galvin
A laboratory-scale REFLUX™ Concentrating Classifier was operated in continuous mode to beneficiate a sub 0.100 mm tantalum ore with a head grade of 0.56 wt.% Ta. The unit incorporated a lower section with a reduced diameter to accommodate a low yield. At a yield to underflow product of 4.0 wt.%, a product grade of 13.3 wt.% was achieved (23.7 upgrade) at a recovery of 88.3%. Samples of the feed, product and reject were then fractionated in a batch REFLUX™ Classifier unit using dense lithium heteropolytungstate (LST) solution into 11 fractions. Each of these fractions was then screened into seven size intervals and analysed by pycnometry and X-ray fluorescence (XRF). Most of the material was found to reside in four relatively narrow density bands. A new analysis based on the recovery of selected tracer elements showed that the partition curve had good closure at both ends and that the density cut point and Ep both increased with decreasing particle size. For the +0.045 mm material, the density cut point was estimated to be around 3952 kg/m3 with an Ep of 317 kg/m3, but it was expected that this new method could overestimate Ep. An alternative novel approach for estimating the partition performance was developed. This method estimated the cut point and Ep values to be 3764 kg/m3 and 107 kg/m3, respectively. However, sensitivity analysis found that due to the near total absence of material in the density range from 3400 kg/m3 to 4700 kg/m3, the Ep could likely lie anywhere in the range from 0 to 250 kg/m3. The methodology proved useful in establishing these limitations in the analysis.