Zouhaira Ben Mahmoud

Dr. Zouhaira Ben Mahmoud


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2024 in Energies
Verified
Journal Article
Open access
PDF file
ZMZouhaira Ben Mahmoud
Zouhaira Ben Mahmoud
AKAdel Khedher
Adel Khedher
Nowadays, transformer-less photovoltaic (PV) multi-level inverters (MLIs) are commonly employed in both industrial and residential settings. This structure has attracted increased attention due to its unique advantages, such as higher efficiency, lower cost and size, better waveform quality, and inherent fault tolerance. However, due to the removal of the transformer, the common mode voltage (CMV) becomes one of the crucial issues in transformer-less PV MLIs. The high-frequency variation in CMV results in a leakage current that deteriorates the line current quality, increases the PV power system losses, leads to severe electromagnetic emissions (EMI), reduces the PV array lifespan, and causes personal safety problems. In this regard, this paper presents a review of the existing and recent research on modulation techniques based on space vector pulse width modulation (SVPWMs) that overcome this issue in transformer-less three-level NPC-MLIs (3L-NPC-MLIs). The reduced CMV-SVPWM (RCMV-SVPWM) can be mainly categorized as an RCMV-SVPWM based on the vector type, based on virtual vectors, and based on the two-level SVPWM (2L-SVPWM). Their features and their limitations in terms of several main criteria are discussed. In the final section of this paper, some challenges and future trends for this research area are projected.


8 June 2024 in Electrical Engineering
Verified
Journal Article
Closed access
PDF file
ZMZouhaira Ben Mahmoud
Zouhaira Ben Mahmoud
TGThouraya Guenenna
Thouraya Guenenna
AKAdel Khedher
Adel Khedher

1 March 2026 in Electricity
Verified
Journal Article
Open access
PDF file
ZMZouhaira Ben Mahmoud
Zouhaira Ben Mahmoud
AKAdel Khedher
Adel Khedher
The use of photovoltaic (PV) water pumping technology offers a viable and sustainable alternative to conventional diesel-driven pumping systems. In PV-based pumping installations, the elimination of bulky transformers significantly reduces the overall system size and weight, which is particularly advantageous for rural and remote irrigation applications. However, removing the transformer can result in high common-mode voltage (CMV) when the induction motor is controlled using a direct torque control (DTC) scheme. This elevated CMV induces leakage currents that may damage the motor, compromise system reliability, and pose potential safety hazards. To ensure a more compact and safer PV pumping system, this paper introduces an improved DTC-based control strategy for induction motors driven by transformerless multilevel PV inverters. The proposed approach effectively suppresses leakage current by mitigating its main source, CMV, while maintaining the simple structure and dynamic performance inherent to conventional DTC. Two new look-up tables (LUTs) are developed to control the stator flux and electromagnetic torque while simultaneously eliminating leakage current. The first method, termed zero-medium vector DTC (ZMV-DTC), employs both zero and medium voltage vectors from the space vector diagram. The second, referred to as medium vector DTC (MV-DTC), utilizes only medium vectors. Numerical simulation results validate the feasibility and superior performance of the proposed algorithms in terms of leakage current suppression. Compared with a conventional DTC (C-DTC) scheme that is designed to limit the CMV, the proposed DTC algorithms achieve a much stronger reduction in the CMV, confining its amplitude to only a few volts, instead of the levels ±Vdc/6 typically produced by the C-DTC. As a result, the leakage current is effectively eliminated, ensuring safer and more reliable operation of the system.

13 February 2026 in Automation
Verified
Journal Article
Open access
PDF file
SJsalma JNAYAH
salma JNAYAH
ZMZouhaira Ben Mahmoud
Zouhaira Ben Mahmoud
TGThouraya Guenenna
Thouraya Guenenna
AKAdel Khedher
Adel Khedher
Common-mode voltage (CMV) is a critical concern in motor drive applications employing multilevel inverters, as it can lead to significant issues such as high-frequency noise, electromagnetic interference, and motor bearing degradation. These effects can compromise the reliability, reduce the operational lifespan of electric machines, and introduce safety hazards. In this study, an enhanced Direct Torque Control (DTC) strategy incorporating Space Vector Modulation (SVM) is proposed to specifically address CMV-related challenges in induction motors (IM) driven by a three-level Neutral-Point-Clamped (NPC) inverter. The proposed DTC scheme utilizes a specialized modulation technique that effectively mitigates CMV while also minimizing current harmonic content, and torque and flux ripples with a constant switching frequency. The developed SVM algorithm simplifies the three-level space vector representation into six equivalent two-level diagrams, enabling more efficient control. The zero-voltage vector is synthesized virtually by combining two active vectors within a two-level hexagonal structure. The effectiveness of the proposed DTC approach is validated through both simulation and Hardware-In-the-Loop (HIL) testing. Compared to the conventional DTC method, the proposed solution demonstrates superior performance in CMV minimization and leakage current reduction. Notably, it limits the CMV amplitude to Vdc/6, a significant improvement over the Vdc/2 typically observed with the standard DTC approach.