Minghao NI

Mr. Minghao NI

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 August 2024 in Fire
Verified
Journal Article
Open access
PDF file
XZXiaokun Zhao
Xiaokun Zhao
MNMinghao NI
Minghao NI
WWWencai Wang
Wencai Wang
HWHongwei Wang
Hongwei Wang
JWJianing Wang
Jianing Wang
To investigate the combustion characteristics of multiple fire sources in the tunnel caused by ‘jumping’ discontinuous fire spread, we utilized scaled model experiments, numerical simulation software, and theoretical research. Our study focused on analyzing the influence of different fire source powers on the temperature characteristics of double fire sources in the tunnel. We examined the temperature characteristics, critical wind speed, and change rule under various wind speeds, fire source spacing, and fire source powers. Additionally, we explored the temperature characteristics, critical wind speed, and change rule of different fire source powers under varying wind speed conditions. The mathematical model for roof temperature decay and the temperature decay coefficients of dual source fires were established through the analysis of scale-down model experiments and numerical simulations. In comparison to single-source fires, the temperature variations in the tunnel of dual source fires exhibit a more intricate pattern, with higher average temperature and temperature peak values. These values are influenced by factors such as fire source spacing and power. Numerical simulation software was utilized to investigate the impact of fire source spacing at 10 m, 15 m, and 20 m, as well as the effect of varying fire source power on the temperature distribution within a tunnel under consistent fire source position and growth coefficient. The study revealed that, with consistent double fire source position and ventilation conditions in the tunnel, the upstream fire source exhibited greater power than the downstream fire source, resulting in the lowest average and peak temperatures in the tunnel. This observation could potentially enhance escape and rescue operations within the tunnel. Similarly, the lowest average and peak temperatures in the tunnel were also identified, offering potential benefits for optimizing escape and rescue strategies in tunnel scenarios.

13 June 2024 in Fire
Verified
Journal Article
Open access
PDF file
MNMinghao NI
Minghao NI
XZXiaokun Zhao
Xiaokun Zhao
WWWencai Wang
Wencai Wang
QZQiongyue Zhang
Qiongyue Zhang
HWHongwei Wang
Hongwei Wang
JWJianing Wang
Jianing Wang
To investigate resistance change in the fire area of a roadway caused by roadway fires, a mathematical calculation model for thermal resistance is developed. Theoretical research is conducted to analyze the factors influencing resistance change through theoretical derivation, revealing that temperature is a key factor contributing to the change in thermal resistance. By leveraging the correlation between changes in CO concentration and temperature on the downwind side of the roadway within the fire zone, researchers developed mathematical models to predict temperature increases at various points downwind of the fire source. These models were then used to determine the mathematical relationship governing the change in thermal resistance. The accuracy of the numerical simulation software was validated using Fluent numerical simulation software and scaled-down model experiments. Full-scale numerical simulation experiments were conducted to investigate the fire characteristics of roadway fires and validate the thermal resistance mathematical model. The results indicate that the thermal resistance in the numerical simulation is 7.55 Pa at 20m from the fire source and 5.54 Pa at the end of the roadway. The decrease in resistance is linear. The minimum error between the thermal resistance calculated by the mathematical model and the gradient of the pressure drop in the numerical simulation is 0.03 Pa, approximately 2.3%. Furthermore, the fitting degree of the pressure drop in each section is as high as 97.7%. The calculation model demonstrates high accuracy and offers a theoretical foundation for investigating fire resistance in tunnel fire.

2 April 2026 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
JZJunzhao Zhang
Junzhao Zhang
HWHaiyan Wang
Haiyan Wang
CLChen Lei
Chen Lei
MNMinghao NI
Minghao NI
CHCheng Hu
Cheng Hu
YZYuxin Zhang
Yuxin Zhang

11 February 2025 in PLOS ONE
Verified
Journal Article
Open access
PDF file
XZXiaokun Zhao
Xiaokun Zhao
MNMinghao NI
Minghao NI
WWWencai Wang
Wencai Wang
JWJianing Wang
Jianing Wang
HWHongwei Wang
Hongwei Wang
In order to address the issues of fire alarm delay, omission, and false alarms caused by the current setup of mine fire sensors, which collect single disaster information, have fixed distribution, and relatively independent data collection, this study utilized FDS numerical simulation software and fire similarity experiments. The aim was to investigate the characteristics of fire gases, temperature, and wind speed. To optimize the number and location of fire sensors in mines, the mathematical method of grey correlation analysis was proposed. Additionally, the critical time for fire hazards to spread to other tunnels was determined by detecting the CO content of ventilation nodes in tunnels with different wind speeds. Grey correlation analysis was employed to determine the critical time for fire hazards to spread to other tunnels. The CO content of the ventilation node is measured to determine the time at which the fire hazard may spread to other tunnels. Grey correlation analysis is then used to compare and correlate the CO content of the ventilation node and the wind speed with the fire characteristic gases, wind speed, and temperature of the tunnel under different wind speeds. Additionally, taking into account the safe escape time for personnel suggested by Marchant, an optimization scheme for the sensors is proposed.