Sabine Van Huffel

Prof. Dr. Sabine Van Huffel

KU Leuven - Department of Electrical Engineering (ESAT)
orcid

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 November 2007 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
HHHans Hallez
Hans Hallez
Bart VanrumsteBart Vanrumste
Bart Vanrumste
RGRoberta Grech
Roberta Grech
JMJoseph Muscat
Joseph Muscat
WCWim De Clercq
Wim De Clercq
ILIgnace Lemahieu
Ignace Lemahieu
The aim of electroencephalogram (EEG) source localization is to find the brain areas responsible for EEG waves of interest. It consists of solving forward and inverse problems. The forward problem is solved by starting from a given electrical source and calculating the potentials at the electrodes. These evaluations are necessary to solve the inverse problem which is defined as finding brain sources which are responsible for the measured potentials at the EEG electrodes.

15 May 2019 in International Journal of Neural Systems
Verified
Journal Article
Open access
PDF file
AAAmir H. Ansari
Amir H. Ansari
PCPerumpillichira J. Cherian
Perumpillichira J. Cherian
ADAlexander Caicedo Dorado
Alexander Caicedo Dorado
Gunnar NaulaersGunnar Naulaers
Gunnar Naulaers
MVMaarten De Vos
Maarten De Vos
SHSabine Van Huffel
Sabine Van Huffel
Identifying a core set of features is one of the most important steps in the development of an automated seizure detector. In most of the published studies describing features and seizure classifiers, the features were hand-engineered, which may not be optimal. The main goal of the present paper is using deep convolutional neural networks (CNNs) and random forest to automatically optimize feature selection and classification. The input of the proposed classifier is raw multi-channel EEG and the output is the class label: seizure/nonseizure. By training this network, the required features are optimized, while fitting a nonlinear classifier on the features. After training the network with EEG recordings of 26 neonates, five end layers performing the classification were replaced with a random forest classifier in order to improve the performance. This resulted in a false alarm rate of 0.9 per hour and seizure detection rate of 77% using a test set of EEG recordings of 22 neonates that also included dubious seizures. The newly proposed CNN classifier outperformed three data-driven feature-based approaches and performed similar to a previously developed heuristic method.

13 October 2017 in Sensors
Verified
Journal Article
Open access
PDF file
KVKaat Vandecasteele
Kaat Vandecasteele
TCThomas De Cooman
Thomas De Cooman
YGYing Gu
Ying Gu
ECEvy Cleeren
Evy Cleeren
KCKasper Claes
Kasper Claes
BHBorbála Hunyadi
Borbála Hunyadi
Electrocardiography has added value to automatically detect seizures in temporal lobe epilepsy (TLE) patients. The wired hospital system is not suited for a long-term seizure detection system at home. To address this need, the performance of two wearable devices, based on electrocardiography (ECG) and photoplethysmography (PPG), are compared with hospital ECG using an existing seizure detection algorithm. This algorithm classifies the seizures on the basis of heart rate features, extracted from the heart rate increase. The algorithm was applied to recordings of 11 patients in a hospital setting with 701 h capturing 47 (fronto-)temporal lobe seizures. The sensitivities of the hospital system, the wearable ECG device and the wearable PPG device were respectively 57%, 70% and 32%, with corresponding false alarms per hour of 1.92, 2.11 and 1.80. Whereas seizure detection performance using the wrist-worn PPG device was considerably lower, the performance using the wearable ECG is proven to be similar to that of the hospital ECG.

1 October 2017 in Early Human Development
Verified
Journal Article
Closed access
ADAnneleen Dereymaeker
Anneleen Dereymaeker
KPKirubin Pillay
Kirubin Pillay
JVJan Vervisch
Jan Vervisch
Maarten De VosMaarten De Vos
Maarten De Vos
SHSabine Van Huffel
Sabine Van Huffel
Gunnar NaulaersGunnar Naulaers
Gunnar Naulaers

14 December 2006 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
JPJean‐Baptiste Poullet
Jean‐Baptiste Poullet
DSDiana Maria Sima
Diana Maria Sima
ASArjan W. Simonetti
Arjan W. Simonetti
BNBart De Neuter
Bart De Neuter
LVLeentje Vanhamme
Leentje Vanhamme
SHSabine Van Huffel
Sabine Van Huffel

23 December 2017 in Sensors
Verified
Journal Article
Open access
PDF file
YGYing Gu
Ying Gu
ECEvy Cleeren
Evy Cleeren
JDJonathan Dan
Jonathan Dan
KCKasper Claes
Kasper Claes
WPWim Van Paesschen
Wim Van Paesschen
BHBorbála Hunyadi
Borbála Hunyadi
A wearable electroencephalogram (EEG) device for continuous monitoring of patients suffering from epilepsy would provide valuable information for the management of the disease. Currently no EEG setup is small and unobtrusive enough to be used in daily life. Recording behind the ear could prove to be a solution to a wearable EEG setup. This article examines the feasibility of recording epileptic EEG from behind the ear. It is achieved by comparison with scalp EEG recordings. Traditional scalp EEG and behind-the-ear EEG were simultaneously acquired from 12 patients with temporal, parietal, or occipital lobe epilepsy. Behind-the-ear EEG consisted of cross-head channels and unilateral channels. The analysis on Electrooculography (EOG) artifacts resulting from eye blinking showed that EOG artifacts were absent on cross-head channels and had significantly small amplitudes on unilateral channels. Temporal waveform and frequency content during seizures from behind-the-ear EEG visually resembled that from scalp EEG. Further, coherence analysis confirmed that behind-the-ear EEG acquired meaningful epileptic discharges similarly to scalp EEG. Moreover, automatic seizure detection based on support vector machine (SVM) showed that comparable seizure detection performance can be achieved using these two recordings. With scalp EEG, detection had a median sensitivity of 100% and a false detection rate of 1.14 per hour, while, with behind-the-ear EEG, it had a median sensitivity of 94.5% and a false detection rate of 0.52 per hour. These findings demonstrate the feasibility of detecting seizures from EEG recordings behind the ear for patients with focal epilepsy.