Padmapriya P

Mrs. Padmapriya P

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2016 in Indian Journal of Science and Technology
Verified
Journal Article
Open access
PDF file
KMK. Manikandan
K. Manikandan
LSLogesh Kumar Sellappan
Logesh Kumar Sellappan
JSJ. Sivaraman
J. Sivaraman
PPPadmapriya P
Padmapriya P
CVC. Vijayalakshmi
C. Vijayalakshmi
Objective: The purpose of the study is to develop a system for measuring the pressure level at several points on the foot sole. Methodology: The pressure sensors placed on the pressure plate develops a voltage for the corresponding exerted pressure and the voltages are amplified to a considerable value and fed into the multiplexer for digitization by using A/D convertor for further processing. All the data are normalized to obtain an appropriate image. The image colour intensities indicate different pressure distributions of the foot. Findings: The diabetes patients are made to walk on the pressure device and the distributions of pressure are simulated with various color coding using Visual Basic (VB) and the range of pressure from minimum to maximum is validated. Applications/Improvements: The pressure distribution of a patient is found in the foot sole and an appropriate foot wear can be designed to avoid foot ulcers and other deformations.

1 January 2025 in Behavioural Neurology
Verified
Journal Article
Open access
PPPadmapriya P
Padmapriya P
VRV. Rajamani
V. Rajamani
Temporary disturbances in brain function are caused by epilepsy, a chronic disorder resulting from sudden abnormal firing of brain neurons. This research introduces an innovative real‐time methodology representing detecting epileptic spasms from electroencephalogram (EEG) data. It employs a support vector machine (SVM) alongside embedded zero tree wavelet (EZW) transform. To facilitate precise multiresolution analysis of epileptic convulsions, the EZW method is selected for its capacity to efficiently compress multichannel EEG data while preserving crucial diagnostic features. EZW effectively captures and encodes key patterns in EEG signals, enabling detailed analysis of the subtle variations associated with seizures. This study extracts statistical features such as entropy, kurtosis, skewness, and mean from the compressed EEG segments. These features are then classified using the SVM to distinguish between normal and epileptic states. With a remarkable 99.02% classification accuracy and a false positive rate of only 1.1%, the proposed algorithm demonstrates excellent performance. The novelty lies in integrating SVM with EZW‐based feature extraction and advanced preprocessing, enabling efficient real‐time EEG analysis. Unlike previous works, this approach preserves critical information, enhances classification accuracy, and supports multichannel signals, offering a robust and practical solution for real‐time epilepsy detection. Based on these findings, the method is considered highly suitable for real‐time implementation in clinical environments.

4 July 2025 in Journal of Environmental Nanotechnology
Verified
Journal Article
Open access
PPPadmapriya P
Padmapriya P
DBD. Banupriya
D. Banupriya
JSJ. Saminathan
J. Saminathan
JWJohn William
John William
MLManoharan Loganathan
Manoharan Loganathan
RPR. Pavithra
R. Pavithra
Efficient management of biomedical waste is essential for ensuring public health and environmental safety. With the growing volume of biomedical waste, effective segregation methods are increasingly necessary. This project focuses on developing an automated biomedical waste segregation device utilizing Arduino technology and sensors. The device categorizes biomedical waste into three distinct types: dry, wet, and metal. An infrared motion sensor identifies the type of waste based on preprogrammed characteristics, while an LCD provides real-time updates on the segregation status. Extensive testing with various types of biomedical waste has demonstrated the device's ability to accurately and efficiently allocate waste to the appropriate bins. Leveraging Arduino and sensor technologies, this system offers a cost-effective and practical solution for biomedical waste segregation. This innovation holds particular promise for addressing waste management challenges in developing countries, where effective biomedical waste handling is a pressing issue. In summary, this project illustrates the potential of using Arduino-based systems for biomedical waste segregation. The device has proven to be reliable, efficient, and economical, offering significant benefits for both public health and environmental safety.

1 January 2023 in SSRN Electronic Journal
Verified
Preprint
Open access
PDF file
PPPadmapriya P
Padmapriya P
DVDr.Rajamani Vayanaperumal Vayanaperumal
Dr.Rajamani Vayanaperumal Vayanaperumal
An electroencephalogram, often known as an EEG test, may be used to diagnose brain illnesses, particularly epilepsy. A thorough examination of the EEG may provide a wealth of information about the brain’s operations. It is of the utmost importance to provide epileptic patients with the therapy of a high standard. Over the last several years, much progress has been made in the field of computer-aided detection (CAD) system research. The development of a supporting system for medical professionals will be beneficial for the speed and accuracy of diagnosis. Classification of the input signal is a major drawback is the existing methodology, so to overcome the defects the proposed methodology includes a Probabilistic Neural Network classifier with Correlated Gravitational Search Algorithm. The location of epileptic foci so EEG can be surgically removed using computer-aided a Probabilistic Neural Network classifier in conjunction with the Correlated Gravitational Search Algorithm, the focus of the observation is on the categorization of EEG signals as either normal or indicative of a seizure. The Gray Level Co-Occurrence Matrix (GLCM) features have been retrieved to represent the huge digitized EEG vectors from the signal in order to train the system utilizing EEG data. The classifier's input is comprised of the extracted characteristics that were taken from the data. For the purpose of determining the classifier's effectiveness, the confusion matrix approach is used. The classifier is measured in terms of performance metrics such as Accuracy, Sensitivity, Specificity, and Recall Rate. The proposed technique achieves an accuracy rate of 95.1%, a precision of95.2%, a Recall rate of 95.0%, a specificity of 95.1%, and an F1 score of 95.12%