Yassine TALEB

Dr. Yassine TALEB


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2024 in Electricity
Verified
Journal Article
Open access
PDF file
YTYassine TALEB
Yassine TALEB
RLRoa Lamrani
Roa Lamrani
AAAhmed Abbou
Ahmed Abbou
This article addresses the need for a standardized method to measure power quality in railroad systems, which differ from distribution and transmission networks. It evaluates the applicability of existing standards in detecting variations and short-term disturbances in railroad networks powered by the 50/60 Hz AC grid or the 2 × 25 kV AC network used for high-speed trains. The objective is to propose a standardized algorithm capable of accurately identifying disturbances to assess power quality on railway traction substations. A new method is proposed to characterize voltage imbalances more precisely. Practical demonstrations confirm that a short integration period, as used in existing standards, provides a more accurate estimation of disturbance amplitude and duration. Field experiments validate the proposed solution, embedded in equipment installed on the 225 kV line supplying the 2 × 25 kV AC substation for high-speed rail. Comparative analysis of results obtained during high-speed train journeys confirms the algorithm’s potential to aid standards committees in reviewing and updating existing standards, as well as expediting the creation, approval, and implementation of new standards for railway installations. Experimental comparisons of other power quality parameters, such as frequency and voltage harmonics, also underscore the algorithm’s utility in railway power quality assessment.

17 February 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
ABAzeddine BOUZBIBA
Azeddine BOUZBIBA
YTYassine TALEB
Yassine TALEB
AAAhmed Abbou
Ahmed Abbou
With the increasing integration of renewable energy sources into the distribution network and the growing complexity of modern power grids, electricity quality has become a major concern. This paper analyzes the performance of a 2 MWp photovoltaic power plant connected to a 22 kV distribution grid, focusing on Total Harmonic Distortion (THD) and voltage unbalances, including homopolar and inverse components. Measurements taken during critical periods, particularly at sunrise and sunset, highlight the need to review energy quality parameters over time intervals shorter than ten minutes to better detect and understand significant deviations, especially in grids with high renewable energy integration. This study highlights the shortcomings of existing standards and proposes revisions to better ad-dress the challenges posed by renewable energy integration. The recommendations aim to improve electricity quality assessment and ensure optimal compatibility with contemporary and future technologies.




30 June 2025 in EPJ Web of Conferences
Verified
Journal Article
Open access
PDF file
YTYassine TALEB
Yassine TALEB
RLRoa Lamrani
Roa Lamrani
RTRedouane Touil
Redouane Touil
AAAhmed Abbou
Ahmed Abbou
The necessity for a consistent technique to assess power quality in railway systems, that are distinct from transmission and distribution networks, is examined in this article. It evaluates whether current standards are suitable for identifying transient fluctuations and disruptions in railway networks driven by the 2×25Kv AC 50Hz network. The purpose is to present a standardized algorithm that can reliably detect disturbances in order to evaluate the quality of electricity on high-speed rail traction substations. A novel approach is put forth to more precisely describe voltage unbalances and the voltage harmonic distortion rate. An accurate estimate of the disturbance's amplitude and duration can be obtained by utilizing a short and adaptable integration period, as supported by empirical data. The suggested solution has been validated through field experiments and is integrated into equipment built on the 225 kV line that supplies the 2×25kV AC substation for high-speed trains. An analysis of the differences between the results obtained from high-speed train operations and the algorithm's ability to help standards committees review and update existing standards as well as expedite the development, approval, and implementation of new standards for railway installation is supported.