Wanda J Gordon-Evans

Dr. Wanda J Gordon-Evans

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2018 in Veterinary Surgery
Verified
Journal Article
Closed access
PDF file
WGWanda J Gordon-Evans
Wanda J Gordon-Evans
AJAnn L. Johnson
Ann L. Johnson
KKKim E. Knap
Kim E. Knap
DGDominique J. Griffon
Dominique J. Griffon

13 December 2019 in Journal of Feline Medicine and Surgery
Verified
Journal Article
Closed access
PDF file
WGWanda J Gordon-Evans
Wanda J Gordon-Evans
HSHanah Y Suh
Hanah Y Suh
Alonso GuedesAlonso Guedes
Alonso Guedes
Recently, a bupivacaine liposome injectable suspension (BLIS) became commercially available in the veterinary market that may provide local analgesia for 72 h. The purpose of this study was to compare a BLIS incisional block to a control protocol in cats after ovariohysterectomy (OHE). The hypothesis was that a BLIS block would provide equivalent pain relief. This study was designed as a randomized, double-blind, non-inferiority trial. Students performed an OHE followed by a two-layer incisional and body wall block with either standard bupivacaine (control) or BLIS. Postoperatively, cats in the control group received robenacoxib, whereas the BLIS cats received saline. All cats were evaluated using the feline Glasgow Composite Measure Pain Scale (GCMPS) at multiple time points postoperatively. There were 24 control cats and 23 BLIS cats. One cat from each group required rescue medication. The mean GCMPS scores were low and the groups were equivalent at all time points (P <0.05). This study showed that BLIS was equivalent to the control group up to 42 h and pain scores remained low up to 68 h after surgery. BLIS incisional block is equivalent to a control pain protocol and reduces the need for continued postoperative drug administration.

17 July 2020 in Veterinary Surgery
Verified
Journal Article
Closed access
PDF file
LSLogan M. Scheuermann
Logan M. Scheuermann
WGWanda J Gordon-Evans
Wanda J Gordon-Evans
ANAndré J. Nault
André J. Nault

18 June 2025 in Animals
Verified
Journal Article
Open access
PDF file
HHHayley Hall
Hayley Hall
RERichard Evans
Richard Evans
MBMakayla Balogh
Makayla Balogh
WGWanda J Gordon-Evans
Wanda J Gordon-Evans
Physiotherapy aims to improve postural dysfunction, often using balance exercises. The effects of rehabilitation-based balance exercises on postural control in dogs remains understudied. This study aimed to assess the impact of specific balancing exercises and blindfolding on center of pressure parameters in healthy dogs. Thirteen healthy adult dogs participated in the study. Center of pressure parameters were measured using a pressure platform during quiet standing, external perturbation, head turn, and blindfolded trials. External perturbation significantly increased the area of the elliptical sway, cranio-caudal excursion, and right–left excursion. Head turning led to large effect sizes, but no significant differences compared to quiet standing. Blindfolding led to medium to large effect sizes, though no significant differences were observed. The study confirmed that external perturbation challenges postural stability, resulting in increased sway. Head turning induces sway but may require further training or different methodologies for reliable outcomes. Blindfolding increased sway but was not statistically different. These findings underscore the potential use of perturbation-based exercises in canine rehabilitation to improve balance, while also highlighting the need for further studies to standardize balance challenges and explore the effects in dogs with orthopedic or neurological conditions.

27 April 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
TJTiffany A. Johnson
Tiffany A. Johnson
WGWanda J Gordon-Evans
Wanda J Gordon-Evans
BLB. Duncan Lascelles
B. Duncan Lascelles
MCMichael G. Conzemius
Michael G. Conzemius
The center of mass (CoM) is the location in a body where mass distribution is balanced. It has a fundamental role in balance and motion which has been poorly described in the dog. The objective of this study was to estimate the variance of the center of mass (CoM) in a heterogeneous population of client-owned dogs and to describe the relationship between CoM, subject morphometrics and an inertial measurement unit (IMU) box positioned ventrally on a neck collar. A single force platform and a reaction board were used to determine CoM in the transverse, sagittal and dorsal planes in thirty-one healthy adult dogs. A series of morphometric measurements were acquired with each dog standing, including distances relative to an IMU box positioned ventrally on a neck collar. Mean transverse plane CoM was 48% the distance from ischium to the IMU box, near the xiphoid process. Mean sagittal place CoM was 59% the width of the chest on the left side. Mean dorsal plane CoM was 41% the distance from the most dorsal to the most ventral aspect of the body. Dog length was the primary variable required to maximize the relationship between three-dimensional CoM and identifiable variables measured. A CoM based normalization procedure should be considered to normalize mass or motion based outcome measure output (e.g., ground reaction forces, vector acceleration) in a heterogeneous population of dogs. Future research will be needed to determine if CoM-based normalization procedures reduce variance in outcome measures affected by subject morphometrics.

21 February 2024 in Veterinary Surgery
Verified
Journal Article
Open access
MPMark Parlier
Mark Parlier
CTChristopher B. Thomson
Christopher B. Thomson
ARAaron Rendahl
Aaron Rendahl
ASAlena Strelchik
Alena Strelchik
CBCaroline Baldo
Caroline Baldo
WGWanda J Gordon-Evans
Wanda J Gordon-Evans
Objective: The adverse effects of intra‐abdominal pressure from capnoperitoneum on cardiovascular and pulmonary systems have been well documented, but the effects on portal pressures in dogs with various insufflation pressures is poorly defined. The aim of the present study was to measure the effect of a range of insufflation pressures on the portal pressure, using direct pressure measurements in patients undergoing laparoscopy.Study design: Clinical randomized prospective study.Animals: Nine client‐owned dogs undergoing routine laparoscopy.Methods: Two rounds of direct portal pressure assessments were performed, at insufflation pressures of 0, 6, 10, and 14 mmHg in a predetermined randomized sequence. The data were analyzed for effects of insufflation pressure, hemodynamic alterations, and round. A best‐fit exponential model of the relationship between portal pressure and insufflation pressure was created.Results: Portal pressure increased by 38% at 6 mmHg, 95% at 10 mmHg, and 175% at 14 mmHg compared to baseline. Portal pressure increased at an average rate of 7.45% per mmHg of insufflation pressure. Effects of weight, weight/insufflation pressure interaction, and round of insufflation were not statistically significant. No systemic hemodynamic adverse events were observed.Conclusion: Portal pressure increased as insufflation pressure increased. There was no clinically significant difference in baseline portal pressure between rounds of insufflation.Clinical significance: This exponential model of portal pressure supports the use of the minimum insufflation pressure to allow visualization during laparoscopy. The return of portal pressure to baseline following desufflation supports the comparison of portal pressure measurements before and after laparoscopic shunt attenuation.