Filippo Scalise

Filippo Scalise

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2007 in Heart and Vessels
Verified
Journal Article
Closed access
PDF file
Giuseppe DerosaGiuseppe Derosa
Giuseppe Derosa
ADAngela D'Angelo
Angela D'Angelo
FSFilippo Scalise
Filippo Scalise
SCStefania Croce
Stefania Croce
CTCarmine Tinelli
Carmine Tinelli
Arrigo CiceroArrigo Cicero
Arrigo Cicero

19 March 2020 in Journal Of Hypertension
Verified
Journal Article
Closed access
SSSahrai Saeed
Sahrai Saeed
FSFilippo Scalise
Filippo Scalise
JCJohn B. Chambers
John B. Chambers
Giuseppe ManciaGiuseppe Mancia
Giuseppe Mancia
In patients with aortic stenosis, the presence of hypertension negatively affects the hemodynamic severity of the stenosis, and worsens adverse left ventricular remodeling. It accelerates the progression of the stenosis and is associated with worse prognosis. Proper management of hypertension is thus crucial but there are concerns about the safety and efficacy of antihypertensive medications as well as uncertainty about optimal blood pressure (BP) targets and their impact on left ventricular mass regression and survival benefits. In the present review, we discuss these issues based on the evidence available in the current literature. Focus is first directed on the consequences of a persistently elevated BP before and after surgical aortic valve replacement or transcatheter valve implantation, and the clinical significance of an abnormal BP response during exercise in patients with significant aortic stenosis. Available data on use of antihypertensive drugs are then critically addressed, the conclusion being that calcium channel blockers may be associated with lower survival, and that diuretics may have disadvantages in patients with left ventricular hypertrophy and smaller left ventricular cavity dimensions, β-blockers may be well tolerated and a better choice for patients with concomitant coronary artery disease and arrhythmias. Renin--angiotensin system blockers improve survival given either before or after valve intervention. Emphasis is placed on the fact that evidence is not derived from randomized trials but only from observational studies. Finally, we discuss the optimal SBP level to reach in patients with aortic stenosis. Again, randomized trials are not available but observational evidence suggests that values between 130 and 139 mmHg systolic and 70–90 mmHg diastolic might represent the best option, and lower BP targets should probably be avoided.

7 September 2021 in Journal of the American Heart Association
Verified
Journal Article
Open access
PDF file
Paolo SalviPaolo Salvi
Paolo Salvi
CBCorrado Baldi
Corrado Baldi
FSFilippo Scalise
Filippo Scalise
Andrea GrilloAndrea Grillo
Andrea Grillo
LSLucia Salvi
Lucia Salvi
GPGianfranco Parati
Gianfranco Parati
Background: Estimation of the balance between subendocardial oxygen supply and demand could be a useful parameter to assess the risk of myocardial ischemia. Evaluation of the subendocardial viability ratio (SEVR, also known as Buckberg index) by invasive recording of left ventricular and aortic pressure curves represents a valid method to estimate the degree of myocardial perfusion relative to left ventricular workload. However, routine clinical use of this parameter requires its noninvasive estimation and the demonstration of its reliability. Methods and Results: Arterial applanation tonometry allows a noninvasive estimation of SEVR as the ratio of the areas directly beneath the central aortic pressure curves obtained during diastole (myocardial oxygen supply) and during systole (myocardial oxygen demand). However, this “traditional” method does not account for the intra‐ventricular diastolic pressure and proper allocation to systole and diastole of left ventricular isometric contraction and relaxation, respectively, resulting in an overestimation of the SEVR values. These issues are considered in the novel method for SEVR assessment tested in this study. SEVR values estimated with carotid tonometry by "traditional” and "new” method were compared with those evaluated invasively by cardiac catheterization. The “traditional” method provided significantly higher SEVR values than the reference invasive SEVR: average of differences±SD= 44±11% (limits of agreement: 23% – 65%). The noninvasive “new” method showed a much better agreement with the invasive determination of SEVR: average of differences±SD= 0±8% (limits of agreement: ‐15% to 16%). Conclusions: Carotid applanation tonometry provides valid noninvasive SEVR values only when all the main factors determining myocardial supply and demand flow are considered.

1 January 2007 in Endothelium
Verified
Journal Article
Closed access
Giuseppe DerosaGiuseppe Derosa
Giuseppe Derosa
Arrigo CiceroArrigo Cicero
Arrigo Cicero
FSFilippo Scalise
Filippo Scalise
SCStefania Croce
Stefania Croce
CTCarmine Tinelli
Carmine Tinelli
ADAngela D'ANgelo
Angela D'ANgelo
The authors hypothesized that matrix metalloproteinase (MMP)-2, -9, and tissue inhibitor metalloproteinase (TIMP)-1, -2 would be abnormal in acute coronary syndromes (ACSs). MMP-2, -9, and TIMP-1, -2 plasma levels were measured in diabetic patients with ACSs compared to nondiabetic patients with ACSs. A total of 46 diabetic and 78 nondiabetic patients with ACSs were enrolled. The following parameters were measured: body mass index (BMI), glycosylated hemoglobin (HbA1c), fasting plasma glucose (FPG), fasting plasma insulin (FPI), homeostasis model assessment index (HOMA index), systolic blood pressure (SBP), diastolic blood pressure (DBP), total cholesterol (TC), low-density lipoprotein cholesterol (LDL-C), high-density lipoprotein cholesterol (HDL-C), triglycerides (Tg), lipoprotein(a) [Lp(a)], plasminogen activator inhibitor-1 (PAI-1), homocysteine (Hct), fibrinogen (Fg), high-sensitivity C-reactive protein (hs-CRP), and plasma levels of MMP-2, MMP-9, TIMP-1, and TIMP-2. Significant HbA1c, FPG, FPI, HOMA index, DBP, Tg, Hct, and Fg increases were present in the diabetic group with ACSs, whereas hs-CRP was lower in these patients compared to nondiabetic patients with ACSs. MMP-9, TIMP-1, and TIMP-2 plasma levels were higher in diabetic patients with ACSs compared to nondiabetic patients with ACSs. MMP-9, TIMP-1, and TIMP-2 plasma levels were increased in diabetic patients with ACSs, which may reflect abnormal extracellular matrix metabolism in diabetes during acute event.

6 May 2013 in Phlebology: The Journal of Venous Disease
Verified
Journal Article
Closed access
FSFilippo Scalise
Filippo Scalise
MFM Farina
M Farina
MMM Manfredi
M Manfredi
CAC Auguadro
C Auguadro
ENE Novelli
E Novelli
Objectives: Chronic cerebrospinal venous insufficiency (CCSVI) is a malformative condition characterized by several anomalies of the azygos and/or internal jugular veins (IJVs). Recommended diagnosis of CCSVI is performed with colour-Doppler (CD) sonography. Though catheter venography (CV) is considered as the gold standard for determining vascular anatomy, its uniplanar point of view does not allow an overall evaluation of endoluminal structures. This limit could be addressed by intravascular ultrasound (IVUS). The aim of this report is to evaluate, in patients with multiple sclerosis (MS), the accuracy of CD sonography and CV versus IVUS in estimating the diameter and the cross-sectional area (CSA) of the IJVs and in detecting jugular endoluminal malformations (JEM). Method: Forty-five MS patients with CCSVI, diagnosed by CD sonography, were submitted to CV during IJVs angioplasty. Twenty-five subjects were also examined with IVUS. The IJVs maximum diameter (MAXD) and CSA were estimated. CD and CV data were compared with IVUS data with the Bland-Altman method. Results: The mean difference in IJV MAXD recorded by CD and IVUS was —0.5 mm. The mean difference in IJV MAXD recorded by CV and IVUS was 3.36 mm. The mean difference in IJV CSA recorded by CD and IVUS was —11.2 mm2. JEM recorded by IVUS were detected by CD sonography and CV with 88% and 32% accuracy, respectively. Conclusions: CV was significantly inferior to CD sonography and IVUS in detecting JEM. Differences between IVUS and CD sonography in detecting JEM and in quantifying jugular diameters were not significant. The IJV CSA was underestimated by CD sonography compared with IVUS. CD sonography was proven to be important in the anatomical characterization of CCSVI, providing useful information for correct intravascular treatment.

1 February 2002 in International Journal of Cosmetic Science
Verified
Journal Article
Closed access
PDF file
FDF. Distante
F. Distante
FSFilippo Scalise
Filippo Scalise
CRC. Rona
C. Rona
ABA. Bonfigli
A. Bonfigli
Joachim FluhrJoachim Fluhr
Joachim Fluhr
Enzo BerardescaEnzo Berardesca
Enzo Berardesca