Hayato Miyachi

Prof. Hayato Miyachi


Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2007 in American Journal of Infection Control
Verified
Journal Article
Closed access
HMHayato Miyachi
Hayato Miyachi
HFHiroyuki Furuya
Hiroyuki Furuya
KUKazuo Umezawa
Kazuo Umezawa
YIYumiko Itoh
Yumiko Itoh
TOToshio Ohshima
Toshio Ohshima
SASatomi Asai
Satomi Asai

17 November 2021 in International Journal of Infectious Diseases
Verified
Journal Article
Open access
SASatomi Asai
Satomi Asai
ASAkira Seki
Akira Seki
YAYasumasa Akai
Yasumasa Akai
HTHiromitsu Tazawa
Hiromitsu Tazawa
HKHidehumi Kakizoe
Hidehumi Kakizoe
HMHayato Miyachi
Hayato Miyachi
We conducted a nationwide external quality assessment (EQA) study of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleic acid amplification testing in Japan. A total of 563 public health and private sector laboratories participated. The EQA samples comprised 6 RNA and full-process controls. The overall agreements were 99.3% and 97.9% for the RNA and full-process controls, respectively. A total of 530/563 (94.1%) laboratories reported correct results; public health laboratories had the highest accuracy. Thirty-three laboratories reported at least one incorrect result (26 laboratories of medical facilities, 5 commercial laboratories, 1 public health laboratory, and 1 other). Sixteen laboratories of medical facilities that used a fully automated assay system failed to detect the presence of the full-process control, due to inherent insufficiency in the limit of detection (LOD). Other causes of incorrect results included failure to ensure the LOD (n = 13), error in result judging or reporting (n = 3), and error in sample handling (n = 1). Performance was mostly dependent on the laboratory category and assay evaluation, particularly the LOD. Guidance should be developed based on these results, particularly in the phase of new entry into laboratory services for SARS-CoV-2.

1 August 1998 in Clinical Chemistry and Laboratory Medicine (CCLM)
Verified
Journal Article
Closed access
PDF file
HMHayato Miyachi
Hayato Miyachi
AMAtsuko Masukawa
Atsuko Masukawa
TOToshio Ohshima
Toshio Ohshima
HFHisae Fusegawa
Hisae Fusegawa
THToru Hirose
Toru Hirose
YAYasuhiko Ando
Yasuhiko Ando
Inhibitors of enzymatic amplification in serum may cause false-negative results for direct detection of hepatitis C virus (HCV) by polymerase chain reaction (PCR). This study was undertaken to demonstrate the importance of the internal control in a PCR assay for detection of HCV-RNA to monitor false-negatives due to inhibitors. HCV-RNA was extracted using RNA extraction kit (SepaGene RV-R, Sanko Junyaku) and a prototype instrument for automated specific capture of HCV-RNA with probes and magnetic bead/fluid separation (Roche Molecular Systems). The extracted HCV-RNA and internal control were detected by an automated PCR machine (Cobas Amplicor, Roche Diagnostic Systems). Addition of hemoglobin (up to 4.5 g/l) to the sera followed by RNA extraction with SepaGene RV-R had no inhibitory effect on the detection of either HCV-RNA or the internal control. In contrast, addition of heparin to the sera showed an inhibitory effect with a dose-dependent manner on the detection of both HCV-RNA and the internal control, with a greater effect at lower copy number of HCV. When HCV-RNA was extracted by the automated system, the inhibitory effect of heparin was successfully eliminated. In the assays of 65 serum samples positive for anti-HCV antibodies, positivity for the internal control indicated efficient amplification and validated 14 negative and two equivocal results for detection of HCV-RNA. Detection of the internal control was negatively correlated with viral copy number in sera suggesting competitive inhibition of high viral copy number on amplification of the internal control. Extraction, coamplification and detection of the internal control appears useful for estimating effects of inhibitors on amplification in each assay for the detection of HCV-RNA, and for evaluating efficacy of RNA extraction methods.

1 January 2000 in Journal of Clinical Microbiology
Verified
Journal Article
Closed access
HMHayato Miyachi
Hayato Miyachi
AMAtsuko Masukawa
Atsuko Masukawa
TOToshio Ohshima
Toshio Ohshima
THToru Hirose
Toru Hirose
CIChaka Impraim
Chaka Impraim
YAYasuhiko Ando
Yasuhiko Ando
We developed and evaluated a prototype automated specimen preparation instrument for the specific capture of hepatitis C virus (HCV) RNA with probes and magnetic bead-fluid separation. HCV RNA was isolated from serum by lysis of virus particles with a chaotropic agent, followed by hybridization of the RNA with biotinylated probes and capture of the hybridized RNA with streptavidin-coated paramagnetic particles. After washing of the hybrid-particle complexes to remove nonspecifically bound materials, the particles were resuspended in a specimen diluent and were then ready for amplification and detection with a fully automated PCR system (COBAS AMPLICOR; Roche Diagnostic Systems). The analytical sensitivity in the dilution series was 33 copies per ml or greater. Comparison of the test results with those obtained by a manual method based on organic extraction and precipitation of RNA (SepaGene RV-R; Sanko Junyaku Co., Ltd.) showed 93% (49 of 53 samples) sensitivity and 100% (12 of 12 samples) specificity. There was 94% overall agreement between results. When RNA was extracted by the manual method from serum containing 103 or 105 copies of HCV per ml in the presence of heparin, there was an inhibitory effect on detection of both HCV RNA and the internal control. In contrast, when RNA was extracted from the serum by the automated method, there was no inhibitory effect. This inhibitory effect of heparin on the manual method was also observed for a series of serum specimens from a hemodialysis patient, but the inhibitory effect was eliminated by the automated specimen preparation method. In summary, a fully automated RNA extraction system for PCR detection of HCV RNA by use of specific capture with probes and magnetic bead-fluid separation was shown to have performance similar to that of the conventional manual method. In addition, it successfully eliminated the inhibitory effect of the heparin in the serum and permitted the detection of HCV RNA in serum samples from a hemodialysis patient. The prototype automated RNA extraction system is suitable as a totally automated system, starting with RNA extraction to detection of HCV, if it was combined with the fully automated COBAS AMPLICOR PCR system.

29 September 2003 in Journal of Clinical Ultrasound
Verified
Journal Article
Closed access
PDF file
NNNaruhiko Nagata
Naruhiko Nagata
HMHayato Miyachi
Hayato Miyachi
ANAtsushi Nakano
Atsushi Nakano
KNKazuhide Nanri
Kazuhide Nanri
HKHisao Kobayashi
Hisao Kobayashi
SMShohei Matsuzaki
Shohei Matsuzaki

1 July 1998 in Acta Haematologica
Verified
Journal Article
Closed access
PDF file
HKHiroshi Kawada
Hiroshi Kawada
RFRyuki Fukuda
Ryuki Fukuda
MYMiyoko Yoshida
Miyoko Yoshida
TKTakeshi Kawakami
Takeshi Kawakami
TKTsutomu Kawada
Tsutomu Kawada
THTomomitsu Hotta
Tomomitsu Hotta
We studied a patient with an indolent leukemia which behaved similarly to chronic lymphocytic leukemia (CLL). Leukemic cells, however, showed larger cell diameters and lower nuclear/cytoplasmic ratios than typical CLL cells, and contained numerous cytoplasmic vacuoles. The cells also demonstrated some morphologic characteristics of hairy cell leukemia. Furthermore, flow-cytometric analysis demonstrated a distinct population of κ/λ double-positive tumor cells, as well as κ single and λ single populations. Southern blot analysis confirmed rearranged bands for both light chains with a monoclonal heavy chain rearrangement. Despite a decision not to treat this asymptomatic patient, disease progression was not observed. This case may represent a unique variant of B lymphoid leukemia. Possible mechanisms of abnormal light chain expression are discussed.