First principles calculations, especially calculations based on the high-throughput density functional theory (DFT), have been widely accepted as the major approach in atom scale materials design. First principles calculations performed in a high-performance computing environment have been used to generate hundreds of thousands of crystal and compound records. The exponential growth of computational materials is one of the main drivers to develop an advanced materials database systems to ensure efficient data storage, management, query, presentation, and manipulation. This review covered the most cutting edge materials database systems in materials design and in important applications, such as fuel cells. By comparing the advantages and drawbacks of these high-throughput first principles materials database systems, an optimized computational framework was suggested to meet the specific needs of fuel cell applications. Further development of high-throughput DFT materials databases, which in essence accelerates materials innovation, was also discussed.
1 January 2012 in Journal of Prosthodontic Research
A digital image correlation (DIC) method for full-field surface strain measurement was used to analyze the effect of two veneering materials for implant supported crowns on the strain distribution within the surrounding bone. An epoxy resin model of a bone block was made by housing acrylic resin replicas of a mandibular first premolar and second molar together with threaded implants replacing the second premolar and first molar. Porcelain-veneered (G1 and G3) and resin-veneered (G2 and G4) screw-retained splinted crowns were fabricated and loaded with (G1 and G2) and without (G3 and G4) the presence of the second molar replica. A 2-dimensional DIC measuring system was used to record surface deformation of the bone block model at a frequency of 1.0 Hz during application of a 250-N load. Maximum compressive strains (ɛ(XX), %) were found for the following regions: between molars, G1 (-0.21), G2 (-0.18), G3 (-0.26), and G4 (-0.25); between implants, G1 (-0.19), G2 (-0.13), G3 (-0.19), and G4 (-0.14). The magnitude of strains in the simulated bone block with the resin-veneered crowns was lower than that with porcelain-veneered crowns, irrespective of the presence or absence of the second molar. The softer resin veneer helped to spread the load more evenly amongst the supporting teeth and implants, thus reducing the strains in the simulant bone block. Conversely, using the harder porcelain veneer resulted in the load being concentrated within one or two teeth or implants, thus leading to higher strain values in the bone block.