In the last few decades, a great amount of interest has developed in the evaluation of the influence of bearing capacity of shallow foundations on slopes. When a footing is placed near a slope the bearing capacity may be reduced. In fact, the failure mechanism is influenced by the distance of the foundation from the edge of the sloping ground. In order to investigate the effect of the bearing capacity of shallow foundations on slopes, model footing tests were performed. This paper presents the results of the investigation, to establish both qualitative and quantitative relationships between the ultimate load of the soil–foundation system and the location of the footing with respect to the slope. Values of ultimate loads deduced from experimental tests are compared with values derived by a numerical analysis based on the limit equilibrium method. Modified bearing capacity factors which take into account the effect of the sloping ground are proposed.
This paper reports on the results of soil-foundation numerical modelling and the seismic response of a cooling tower founded on piles of a petrochemical facility located in the city of Augusta (Sicily, Italy). The city was affected in the past by some destructive earthquakes (1693, 1848, and 1990) that damaged a large territory of Southeastern Sicily, which was characterized by a very high seismic hazard. With this aim, the paper reports the FEM modelling of the seismic behaviour of the coupled soil-structure system. To determine the soil profile and the geotechnical characteristics, laboratory and in situ investigations were carried out in the studied area. The seismic event occurred in January 1693 and has been chosen as a scenario earthquake. Moreover, a parametric study with different input motions has also been carried out. A Mohr-Coulomb model has been adopted for the soil, and structural elements have been simulated by means of an elastic constitutive model. Two different vertical alignments have been analysed, considering both the free-field condition and the soil-structure interaction. The dynamic response has been investigated in terms of accelerations, response spectra, and amplification functions. The results have also been compared with those provided by Italian technical regulations. Finally, the seismic response of the coupled soil-structure system has been further examined in terms of peak bending moments along the pile foundation, emphasizing the possibility of a kinematic interaction on piles induced by the seismic action.
This paper analyses the effect of polyurethane injections on the seismic surficial response of cohesionless soils. For this purpose, dynamic finite element numerical analyses were performed through GiD + OpenSees. Both the soil and the composite material, resulted after the expansion of the injected polyurethane, are modelled with a nonlinear hysteretic constitutive model. Based on the polyurethane percentage, a homogenisation of the characteristics was considered for the composite material: linear for density and damping, and exponential (experimentally calibrated) for the stiffness. An expansion coefficient quantifies how much the injected polyurethane expands: three expansion coefficients were considered, each of them related to a different polyurethane density. For the evaluation of the foam stiffness, a linear stiffness–density correlation was used, derived after impact tests. Results showed that polyurethane reduces the surficial accelerations proportionally to the ratio of its seismic impedance and volumetric percentage with respect to the soil seismic impedance and total volume. This is a preliminary indication for the design of polyurethane injections in cohesionless soils for seismic acceleration reduction.