The objective of this study is to observe the visual fatigue caused by watching 3DTV using the method of functional magnetic resonance imaging (fMRI). The data of fMRI during three kinds of visual stimulation tasks were obtained from twenty subjects. At first, blood-oxygen-level dependent (BOLD) signal changes during stimuli of checkerboard task were compared before and after one-hour watching 3D/2DTV, and subjective evaluation was conducted based on the questionnaire simultaneously. Then 3D and 2D images were used to stimulate healthy individuals to measure brain activities that correlated with stereoscopic vision. Finally, the relationship between front or back depth of field images and visual fatigue was investigated. The results reveal that the 3D group shows more significant differences of brain activities in BA8, BA17, BA18 and BA19 than the 2D group during the checkerboard stimulation. BA5, BA6, BA7 and BA8 were testified to have close relationship with stereoscopic perception via the 2D/3D images stimulation. Furthermore, the front depth of field image was proven to impose a more serious impact on visual fatigue than the back one. These conclusions are useful for healthy and reasonable 3DTV watching as well as properly designing of 3D scenes.
26 October 2022 in Computers in Biology and Medicine
The detection of the pectoral muscle boundary in the medio-lateral oblique view of mammograms is essential to improving the computer-aided diagnosis of breast cancer. In this study, a shape-based detection method is proposed for accurately extracting the boundary of the pectoral muscle in mammograms. A shape-based enhancement mask is applied to the mammogram and the initial boundary is then defined using morphological operators. The seed point is then detected on the initial boundary and the pectoral boundary is evolved from candidate points produced using a shape-based growth strategy. A cubic polynomial fitting function is implemented to obtain the final pectoral muscle boundary. The proposed method was applied to 322 mammograms from the mini Mammographic Image Analysis Society database. A 97.2 % acceptable rate from expert radiologists and assessment results based on the false positive rate, false negative rate, and Hausdorff distance demonstrate the robustness and effectiveness of the proposed shape-based detection method.
Objective . Computed tomography (CT) and magnetic resonance imaging (MRI) are widely used in medical imaging modalities, and provide valuable information for clinical diagnosis and treatment. However, due to hardware limitations and radiation safety concerns, the acquired images are often limited in resolution. Super-resolution reconstruction (SR) techniques have been developed to enhance the resolution of CT and MRI slices, which can potentially improve diagnostic accuracy. To capture more useful feature information and reconstruct higher quality super-resolution images, we proposed a novel hybrid framework SR model based on generative adversarial networks. Approach . The proposed SR model combines frequency domain and perceptual loss functions, which can work in both frequency domain and image domain (spatial domain). The proposed SR model consists of 4 parts: (i) the discrete Fourier transform (DFT) operation transforms the image from the image domain to frequency domain; (ii) a complex residual U-net performs SR in the frequency domain; (iii) the inverse discrete Fourier transform (iDFT) operation based on data fusion transforms the image from the frequency domain to image domain; (iv) an enhanced residual U-net network is used for SR of image domain. Main results . Experimental results on bladder MRI slices, abdomen CT slices, and brain MRI slices show that the proposed SR model outperforms state-of-the-art SR methods in terms of visual quality and objective quality metric such as the structural similarity (SSIM) and the peak signal-to-noise ratio (PSNR), which proves that the proposed model has better generalization and robustness. (Bladder dataset: upscaling factor of 2: SSIM = 0.913, PSNR = 31.203; upscaling factor of 4: SSIM = 0.821, PSNR = 28.604. Abdomen dataset: upscaling factor of 2: SSIM = 0.929, PSNR = 32.594; upscaling factor of 4: SSIM = 0.834, PSNR = 27.050. Brain dataset: SSIM = 0.861, PSNR = 26.945). Significance . Our proposed SR model is capable of SR for CT and MRI slices. The SR results provide a reliable and effective foundation for clinical diagnosis and treatment.