Maria Naumenko

Maria Naumenko


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 June 2024 in Polymers
Verified
Journal Article
Open access
PDF file
VPValentina A. Petrova
Valentina A. Petrova
DPDaria Poshina
Daria Poshina
AGAlexey Golovkin
Alexey Golovkin
AMAlexander Mishanin
Alexander Mishanin
SZSergei G. Zhuravskii
Sergei G. Zhuravskii
Yury A. SkorikYury A. Skorik
Yury A. Skorik
Cerium oxide nanoparticles (CeONPs), as part of tissue regeneration matrices, can protect cells from reactive oxygen species and oxidative stress. In addition, they can influence the properties of the scaffold, including its electrospinnability and mechanical strength. In this work, we prepared electrospun fiber mats from a chitosan and polyethylene oxide blend (CS-PEO) with the addition of ceria nanoparticles (CS-PEO-CeONP). The addition of CeONPs resulted in a smaller fiber diameter and higher swelling compared to CS-PEO fiber mats. CeONP-modified fiber mats also had a higher Young’s modulus due to the reinforcing effect of the nanoparticles. Both mats had comparable adhesion and cytocompatibility to mesenchymal stem cells, which had a more rounded morphology on CS-PEO-CeONP compared to elongated cells on the CS-PEO mats. Biocompatibility in an in vivo rat model showed no acute toxicity, no septic or allergic inflammation, and no rough scar tissue formation. The degradation of both mats passed the stage of matrix swelling. CS-PEO-CeONP showed significantly slower biodegradation, with most of the matrix remaining in the tissue after 90 days. The reactive inflammation was aseptic in nature with the involvement of multinucleated foreign-body type giant cells and was significantly reduced by day 90. CeONPs induced the formation of the implant’s connective tissue capsule. Thus, the introduction of CeONPs influenced the physicochemical properties and biological activity of CS-PEO nanofiber mats.

Verified
Journal Article
Open access
PDF file
VPValentina A. Petrova
Valentina A. Petrova
Natallia DubashynskayaNatallia Dubashynskaya
Natallia Dubashynskaya
SZSergei G. Zhuravskii
Sergei G. Zhuravskii
DPDaria Poshina
Daria Poshina
AGAlexey Golovkin
Alexey Golovkin
Yury A. SkorikYury A. Skorik
Yury A. Skorik
The development of advanced wound dressings that integrate favorable physico-mechanical properties with the ability to support physiological healing processes remains a critical challenge in biomaterials science. An ideal dressing should modulate the wound microenvironment, prevent infection, maintain hydration, and possess adequate strength and elasticity. This study aimed to fabricate and characterize electrospun chitosan (CS)-based 3D scaffolds dual-reinforced with halloysite nanotubes (HNTs) and cerium oxide nanoparticles (CeONPs) to enhance material properties and biological performance. HNTs were incorporated to improve electrospinnability and provide mechanical reinforcement, while CeONPs were added for their redox-modulating and anti-inflammatory activities. Composite mats were fabricated via non-capillary electrospinning. The individual and synergistic effects of HNTs and CeONPs were systematically evaluated using physico-chemical methods (SEM, EDX, WAXS, TGA, mechanical testing) and biological assays (in vitro cytocompatibility with mesenchymal stem cells, in vivo biocompatibility, and wound healing efficacy in a rat model). Scaffolds containing only HNTs exhibited defect-free nanofibers with an average diameter of 151 nm, whereas the dual-filler (CS-PEO-HNT-CeONP) composites showed less uniform fibers with a rough surface and a larger average diameter of 233 nm. The dual-filler system demonstrated significantly enhanced mechanical properties, with a Young’s modulus nearly double that of pure CS mats (881 MPa vs. 455 MPa), attributed to strong interfacial interactions. In vivo, the CS-PEO-HNT-CeONP scaffolds degraded more slowly, promoted earlier formation of a connective tissue capsule, and elicited a reduced inflammatory response compared to single-filler systems. Although epithelialization was temporarily delayed, the dual-filler composite ultimately facilitated superior tissue regeneration, characterized by a more organized, native-like collagen architecture. The synergistic combination of HNTs and CeONPs within a CS matrix yields a highly promising scaffold for wound management, offering a unique blend of tailored biodegradability, enhanced mechanical strength, and the ability to guide healing towards a regenerative rather than a fibrotic outcome, particularly for burns and traumatic injuries.

26 October 2023 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
MNMaria Naumenko
Maria Naumenko
Petr P. SnetkovPetr P. Snetkov
Petr P. Snetkov
TGTatiana Gribinichenko
Tatiana Gribinichenko
ABAnna Bervinova
Anna Bervinova
SMSvetlana Morozkina
Svetlana Morozkina
SZSergei Zhuravskii
Sergei Zhuravskii
Septal cartilage defects and tympanic membrane perforations are some of the main challenging clinical problems in modern ENT (Ear, Nose and Throat) surgery. Polymer films based on biocompatible and biodegradable polymers seem to represent prospective materials for surgical reconstruction of such defects. In this study, we present the results of pilot in vivo experiments of the biocompatibility and biodegradability of bilayer films obtained via the casting method from hyaluronic acid (MW = 1300 kDa) and chitosan (500 and 900 kDa) polymer solutions. The total toxicity, pro-inflammatory activity, biodegradation rate and proliferative potential of the connective tissue of the dermis in the implantation area were evaluated on days 7, 14, 30 and 50 after the implantation. The studied samples demonstrated negligible overall acute and chronic toxicity. The influence of the preparation technique as well as the effect of chitosan’s MW on the biodegradation rate are also demonstrated. These bilayer polymer films can be recommended for ENT surgery, in particular for the reconstruction of the nasal septum and tympanic membrane.

15 February 2024 in Folia Otorhinolaryngologiae et Pathologiae Respiratoriae
Verified
Journal Article
Closed access
PDF file
MNMaria Naumenko
Maria Naumenko
Petr P. SnetkovPetr P. Snetkov
Petr P. Snetkov
SMSvetlana Morozkina
Svetlana Morozkina
ABAnna N. Bervinova
Anna N. Bervinova
GYGalina Yu. Yukina
Galina Yu. Yukina
ЖГЖуравский Сергей Григорьевич
Журавский Сергей Григорьевич
BACKGROUND: Biocompatible polymer matrices are extensively investigated as materials for the reconstruction of chronic tympanic perforations. AIM: This study aimed to evaluate the general and local toxicity and biodegradation and biocompatibility mechanism of samples of two-layer polymer films based on chitosan (CS) and hyaluronic acid (HA). MATERIALS AND METHODS: Bilayer polymer films were prepared by the casting method using CS solutions with molecular weights of 500 and 900 kDa (CS500 and CS900, respectively) and HA with a molecular weight of 1300 kDa. The samples were also treated at 100°C for 5 min (samples marked with t). The toxicity, biodegradation rate, and biocompatibility of the materials were evaluated in 20 Wistar rats weighing 220–240 g. The rats were observed on days 7, 14, 30, and 50 after subcutaneous implantation. RESULTS: No acute toxicity, septic or allergic inflammation, or scarring of surrounding tissues was observed during the post-implantation period. The biodegradation rate decreased in the following order: CS500-HA (whitout t) ≥ CS900-HA (whitout t) CS500-HA (t) CS900_HA (t). The study demonstrated the effect of CS in different molecular weights and thermal treatment on the degradation rate and polymer implant biodegradation as well as the type of reactive proliferation of the connective tissue. CONCLUSIONS: These results support further preclinical research on polymer film samples for the development of matrices for tympanoplasties.

4 September 2026 in Journal of Biomaterials Science, Polymer Edition
Verified
Journal Article
Closed access
AKAnna Kosova
Anna Kosova
MNMaria Naumenko
Maria Naumenko
SZSergei G. Zhuravskii
Sergei G. Zhuravskii
GYGalina Y. Yukina
Galina Y. Yukina
ESElena G. Sukhorukova
Elena G. Sukhorukova
SMSvetlana Morozkina
Svetlana Morozkina
Regenerative medicine in otorhinolaryngology faces substantial challenges in restoring of middle ear structures, particularly the eardrum, because the traditional methods have the limitations. In t...

4 September 2026 in Russian Bulletin of Otorhinolaryngology
Verified
Journal Article
Closed access
SZS.G. Zhuravskii
S.G. Zhuravskii
NSN.A. Stepanov
N.A. Stepanov
MNMaria Naumenko
Maria Naumenko
IMI.A. Makhnin
I.A. Makhnin
An experimental in vivo model of cisplatin-induced ototoxicity (CO) is a prerequisite for developing methods to prevent hearing loss resulting from cisplatin (CP) chemotherapy. However, there are no clear guidelines regarding its design in a research model as widely used as the Wistar rat. Objective. To develop and validate a model of auditory analyzer injury in Wistar rats that reflects the specific nature of cisplatin-induced ototoxicity. Material and methods. The study was conducted on male Wistar rats of SPF status, n=24, weighing 300–340 g. CP was administered in doses of 6, 8, 10, and 12 mg/kg as a single intraperitoneal injection to four groups of 6 rats (12 ears). Survival, body weight and audiological parameters were assessed. Otoacoustic emissions at the distortion product frequency (DP OAE) and auditory brainstem responses (ABR) were examined at baseline and on day 30 of the experiment. The amplitude of DP OAE was assessed at 8 and 10 kHz; ABR was assessed during monaural stimulation with 20 and 30 kHz tones in a free sound field. Additionally, plasma creatinine levels and histological preparations of cochleae and kidneys were assessed. Results. A single administration of CP at a dose of 8 mg/kg or higher in Wistar rats is associated with acute mortality. A CIOT model allowing for animal survival is achieved using CP at a dose of 6 mg/kg. In this case, by the end of the experiment, a decrease in the amplitude of the OAE in the 10 kHz range was noted (p=0.043); for the ABR, an increase in the threshold by 10–15 dB in response to a 20 kHz stimulus was observed in 3 out of 12 ears, along with a decrease in the amplitude of the second peak (p=0.012). Histological sections of the temporal bones revealed partial neuronal death in the spiral ganglion of the cochlea’s main turn. Kidney tissue showed irreversible damage characteristic of tubulo-interstitial nephritis. However, plasma creatinine levels remained within the reference range. Conclusion. A single intraperitoneal administration of CP at a dose of 6 mg/kg allows the establishment of a model of acute CO in adult Wistar rats, characterized by moderate depression of audiological parameters and irreversible pathomorphological changes in the neurons of the spiral ganglion. The absence of mortality and biochemical signs of nephrotoxicity indicates specific damage to the peripheral component of the auditory system without the additional ototoxic influence of renal failure factors.