Increasing demand on heating, ventilation, and air-conditioning (HVAC) systems and their importance, as the respiratory system of buildings, in developing and spreading various microbial contaminations and diseases with their huge global energy consumption share have forced researchers, industries, and policymakers to focus on improving the sustainability of HVAC systems. Understanding and considering various parameters related to the sustainability of new and existing HVAC systems as the respiratory system of buildings are vital to providing healthy, energy-efficient, and economical options for various building types. However, the greatest opportunities for improving the sustainability of HVAC systems exist at the design stage of new facilities and the retrofitting of existing equipment. Considering the high available percentage of existing HVAC systems globally reveals the importance of their retrofitting. The attempt has been made to gather all important parameters that affect decision-making to select the optimum HVAC system development considerations among the various opportunities that are available for sustainability improvement.
1 May 2021 in Saudi Journal of Biological Sciences
Food waste (FW) minimization at the source by using food waste biodigester (FWBs) has a vast potential to lower down the impact of increasing organic fraction in municipal solid waste generation. To this end, this research sought to check the performance of locally isolated hydrolase-producing bacteria (HPB) to improve food waste biodegradation rate. Two under-explored HPB identified as Bacillus paralicheniformis GRA2 and Bacillus velezensis TAP5 were able to produce maximum amylase, cellulase, protease and lipase activities, and demonstrated a significant hydrolase synergy in co-culture fermentation. In vitro biodegradation analysis of both autoclaved and non-autoclaved FW revealed that the HPB inoculation was effective to degrade total solids (>62%), protein (>19%), total fat (>51), total sugar (>86%), reducing sugar (>38%) and starch (>50%) after 8-day incubation. All co-culture treatments were recorded superior to the respective monocultures and the uninoculated control. The results of FW biodegradation using batch-biodigester trial indicated that the 1500 mL and 1000 mL inoculum size of HPB inoculant reached a plateau on the 4th day, with gross biodegradation percentage (GBP) of >85% as compared to control (66.4%). The 1000 mL inoculum was sufficient to achieve the maximum GBP (>90%) of FW after an 8-day biodigestion in a FWB.
As of 2022, roughly 79.8% of Malaysia’s population resides in urban areas, increasing the population density of its cities. The hot and humid climate in Malaysia necessitates the constant use of air conditioning, especially in cities, resulting in high residential electric consumption and carbon emissions. The residential sector significantly contributes to global climate change, accounting for 27% of global energy consumption and 17% of carbon emissions. To address this concern, the local framework of the National Low Carbon Cities Masterplan (NLCCM) is advocating for a minimum 33% reduction in carbon emissions by 2030 in urban settings, aligning with the commitments made at the 15th Conference of Parties (COP 15). The aim of this study was to determine the energy consumption and carbon emission of residential areas in a tropical city, as well as explore potential energy and carbon savings. Utilizing the Intelligent Communities Lifecycle–Intelligent Community Design (iCL-iCD) energy simulation software, a digital twin of Bertam City, Penang, was developed. This digital model included 65.4% residential housing, which, in the specific scenario under study, accounted for 36% of the city’s electrical energy consumption for cooling purposes only. An early simulation of the residential areas of the city estimated the baseline energy consumption and carbon emissions to be 607 GWh and 314,736 tCO2e, respectively. Several energy-efficient measures were applied to the residential area of Bertam City, revealing a potential saving of 37.3% in both energy and carbon emissions.
Hot and humid climates challenge conventional residential designs in maintaining thermal comfort, often leading to a heavy reliance on energy-intensive mechanical cooling. This dependence increases operational costs and contributes to elevated carbon emissions. In rapidly urbanising regions such as Selangor, Malaysia, climate-responsive and sustainable design strategies are urgently needed. This study evaluates the effectiveness of passive design strategies in enhancing indoor thermal comfort in naturally ventilated residential buildings using a three-case study methodology. Empirical field measurements were conducted to examine the influence of shading, building orientation, natural ventilation, and material selection on operative temperature Top and perceived comfort. The findings indicate that integrating passive strategies significantly improves indoor thermal conditions. Residence A, incorporating effective cross-ventilation and thermal mass, achieved the lowest operative temperature range of 28.5 °C to 29.8 °C, remaining within the 90% adaptive comfort band, with favourable air velocities between 0.45 and 0.65 m/s. In contrast, Residence B recorded higher operative temperatures from 29.5 °C to 31.2 °C, up to 1.4 °C warmer than Residence A, due to mean radiant temperatures exceeding 31 °C and a near-stagnant airflow below 0.10 m/s. Although Residence C demonstrated moderated radiant temperatures between 28.2 °C and 29.5 °C through effective envelope design, operative temperatures remained warm, ranging from 29.0 °C to 30.5 °C, due to severely restricted air velocities below 0.05 m/s. Overall, the results demonstrate that combinations of low air velocity (30 °C) consistently drive operative conditions beyond the upper 90% adaptive comfort threshold, confirming ventilation effectiveness is the primary control factor of thermal acceptability in tropical residential environments.
Following the UN Climate Change Conference 2009 in Copenhagen, Denmark, Malaysia seriously committed on “Go Green” campaign with the aim to reduce 40% GHG emission by the year 2020. Therefore, the National Green Technology Policy has been legalised in 2009 with transportation as one of its focused sectors, which include hybrid (HEVs), electric vehicles (EVs) and fuel cell vehicles with the purpose of to keep up with the worst scenario. While the number of registered cars has been increasing by 1 million yearly, the amount has doubled in the last two decades. Consequently, CO2 emission in Malaysia reaches up to 97.1% and will continue to increase mainly due to the activities in the transportation sector. Nevertheless, Malaysia is now moving towards on green car which battery-based EVs. This type of transportation mainly needs power performance optimization, which is controlled by the Batteries Management System (BMS). BMS is an essential module which leads to reliable power management, optimal power performance and safe vehicle that lead back for power optimization in EVs. Thus, this paper proposes power performance optimization for various setups of lithium-ion cathode with graphene anode using MATLAB/SIMULINK software for better management performance and extended EVs driving range.
Indoor environmental quality (IEQ), encompassing thermal comfort and indoor air quality (IAQ), plays a crucial role in occupant well-being and operational performance. Although widely studied individually, integrating thermal comfort and IAQ assessments remains limited, particularly in large-scale tropical commercial settings. Hypermarkets, characterised by spatial heterogeneity and fluctuating occupancy, present challenges that conventional HVAC systems often fail to manage effectively. This study investigates thermal comfort and IAQ variability in a hypermarket located in Gombak, Malaysia, under tropical rainforest conditions based on the Köppen–Geiger climate classification, a widely used system for classifying the world’s climates. Environmental parameters were monitored using a network of IoT-enabled sensors across five functional zones during actual operations. Thermal indices (PMV, PPD) and IAQ metrics (CO2, TVOC, PM2.5, PM10) were analysed and benchmarked against ASHRAE 55 standards to assess spatial variations and occupant exposure. Results revealed substantial heterogeneity, with the cafeteria zone recording critical discomfort (PPD 93%, CO2 900 ppm, TVOC 1500 ppb) due to localised heat and insufficient ventilation. Meanwhile, the intermediate retail zone maintained near-optimal conditions (PPD 12%). Although findings are specific to this hypermarket, the integrated zone-based monitoring provides empirical insights that support the enhancement of IEQ assessment approaches in tropical commercial spaces. By characterising zone-specific thermal comfort and IAQ profiles, this study contributes valuable knowledge toward developing adaptive, occupant-centred HVAC strategies for complex retail environments in hot-humid climates.