Orthostatic lightheadedness in healthy young adults often leads to syncope in severe cases. One suggested underlying mechanism of orthostatic lightheadedness is a drop in transient blood pressure (BP); however, a decrease in BP does not always lead to a drop in cerebral blood flow (CBF) due to cerebral autoregulation (CA). We present a direct assessment method of CA using a multichannel continuous-wave near-infrared spectroscopy (CW-NIRS) device that measures the temporal changes in oxy- and deoxy-hemoglobin concentrations in the prefrontal cortex. Twenty healthy young adults were recruited. During the experiment, continuous beat-to-beat BP and heart rate were simultaneously measured during repetitive squat-stand maneuvers. We introduce a new metric termed ‘time-derivative hemodynamic model (DHbT)’, which is the time-derivative of total-hemoglobin concentration change that reflects the changes of cerebral blood volume and CBF. Although the absolute levels and the variations of systolic and diastolic BPs and mean arterial pressure showed no significant difference between the two groups, the proposed model showed a distinct difference in slope variation and response time of DHbT between the subjects with frequent symptom of orthostatic intolerance and the healthy control subjects. Thus, these results clearly demonstrate the feasibility of using CW-NIRS devices as a CA performance assessment tool.
3 December 2014 in IEEE Journal of Solid-State Circuits
This paper describes a low-power 100 Gigabit Ethernet transceiver IC compliant with IEEE802.3ba 100GBASE-LR4 in 40 nm CMOS. The proposed bidirectional full-duplex transceiver IC contains a total of eight 28 Gb/s CDRs. Each CDR lane incorporates phase-rotator-based delay- and phase-locked loop (D/PLL) architecture for enhanced jitter filtering. All the CDR lanes operate independently while sharing a single voltage-controlled oscillator and supporting referenceless clock acquisition. To reduce power consumption, a multidrop clock distribution scheme with single on-chip transmission-line (T-line) and quadrate RX and TX schemes without CML logic gates are incorporated. Embedded built-in self-test modules featuring a random accumulation jitter generator enables bit error rate (BER) and jitter tolerance self tests without any external equipment. The TX featuring a three-tap pre-emphasis provides a variable output swing ranging from 478 mVppd to 1.06 Vppd. RX equalizers employing a continuous-time linear equalizer and a one-tap decision feedback equalizer compensate for the channel loss up to 25 dB at the Nyquist rate. The measured RX input sensitivity for a BER of 10 -12 is 42 mVppd. The proposed IC consumes only 0.87 W at 28.0 Gb/s with a BER less than 10 -15 on PRBS31 testing. The power efficiency of the proposed transceiver is 3.9 mW/Gb/s, which is the best among the efficiencies achieved by recently published 25 Gb/s transceivers.
The ever-increasing demand for bandwidth triggered by mobile and video Internet traffic requires advanced interconnect solutions satisfying functional and economic constraints. A new interconnect called E-TUBE is proposed as a cost-and-power-effective all-electrical-domain wideband waveguide solution for high-speed high-volume short-reach communication links. The E-TUBE achieves an unprecedented level of performance in terms of bandwidth-per-carrier frequency, power and density without requiring a precision manufacturing process unlike conventional optical/waveguide solutions. The E-TUBE exhibits a frequency-independent loss-profile of 4 dB/m and has nearly 20-GHz bandwidth over the V band. A single-sideband signal transmission enabled by the inherent frequency response of the E-TUBE renders two-times data throughput without any physical overhead compared to conventional radio frequency communication technologies. This new interconnect scheme would be attractive to parties interested in high throughput links, including but not limited to, 100/400 Gbps chip-to-chip communications.
This study aims to enhance breast cancer detection accuracy through an AI-driven ultrasound tool, Vis-BUS, developed by Barreleye Inc., Seoul, South Korea. Vis-BUS incorporates Lesion Detection AI (LD-AI) and Lesion Analysis AI (LA-AI), along with a Cancer Probability Score (CPS), to differentiate between benign and malignant breast lesions. A retrospective analysis was conducted on 258 breast ultrasound examinations to evaluate Vis-BUS’s performance. The primary methods included the application of LD-AI and LA-AI to b-mode ultrasound images and the generation of CPS for each lesion. Diagnostic accuracy was assessed using metrics such as the Area Under the Receiver Operating Characteristic curve (AUROC) and the Area Under the Precision-Recall curve (AUPRC). The study found that Vis-BUS achieved high diagnostic accuracy, with an AUROC of 0.964 and an AUPRC of 0.967, indicating its effectiveness in distinguishing between benign and malignant lesions. Logistic regression analysis identified that ‘Fatty’ lesion density had an extremely high odds ratio (OR) of 27.7781, suggesting potential convergence issues. The ‘Unknown’ density category had an OR of 0.3185, indicating a lower likelihood of correct classification. Medium and large lesion sizes were associated with lower likelihoods of correct classification, with ORs of 0.7891 and 0.8014, respectively. The presence of microcalcifications showed an OR of 1.360. Among Breast Imaging-Reporting and Data System categories, category C5 had a significantly higher OR of 10.173, reflecting a higher likelihood of correct classification. Vis-BUS significantly improves diagnostic precision and supports clinical decision-making in breast cancer screening. However, further refinement is needed in areas like lesion density characterization and calcification detection to optimize its performance.
The demand for advanced interconnects to satisfy market requirements on bandwidth, cost, and power is ever increasing with the expansion of data centers. An interconnect called E-TUBE is presented as a cost-and-power-efficient all-electrical-domain wideband waveguide solution for high-speed high-volume short-reach communication links. The E-TUBE achieves an unprecedented level of throughput-distance product, bending radius, and channel density without requiring complex manufacturing process. The E-TUBE link demonstrates nearly 25 GHz bandwidth at a carrier frequency of 70 GHz and exhibits a frequency-independent insertion loss of 5 dB/m with a frequency-independent group delay of 4 ns/m. Such loss and delay characteristics independent of frequency enabled broadband data transmission over extended reach compared to conventional waveguide links. The E-TUBE link transmits 25 Gbps NRZ data over 3 m distance using a 70 GHz RF CMOS transceiver IC, which is the state-of-the-art throughput-reach product. This new interconnect is expected to overcome the limitations of existing electrical and optical interconnects and to replace them in high throughput links, including but not limited to, 100/400 Gbps board-to-board communications.
7 June 2021 in IEEE Transactions on Biomedical Engineering
Objective: The speed of sound (SoS) has great potential as a quantitative imaging biomarker since it is sensitive to pathological changes in tissues. In this paper, a target-aware deep neural (TAD) network reconstructing an SoS image quantitatively from pulse-echo phase-shift maps gathered from a single conventional ultrasound probe is presented. Methods: In the proposed TAD network, the reconstruction process is guided by feature maps created from segmented target images for accuracy and contrast. In addition, the feature extraction process utilizes phase difference information instead of direct pulse-echo radio frequency (RF) data for robust image reconstruction against noise in the pulse-echo data. Results: The TAD network outperforms the fully convolutional network in root mean square error (RMSE), contrast-to-noise ratio (CNR), and structural similarity index (SSIM) in the presence of nearby reflectors. The measured RMSE and CNR are 5.4 m/s and 22 dB, respectively with the tissue attenuation coefficient of 2 dB/cm/MHz, which are 72% and 13 dB improvement over the state of the art design in RMSE and CNR, respectively. In the in-vivo test, the proposed method classifies the tissues in the neck area using SoS with a p-value below 0.025. Conclusion: The proposed TAD network is the most accurate and robust single-probe SoS image reconstruction method reported to date. Significance: The accuracy and robustness demonstrated by the proposed SoS imaging method open up the possibilities of wide-spread clinical application of the single-probe SoS imaging system.