Claudia Rahmann

Dr. Claudia Rahmann

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 December 2020 in IEEE Transactions on Power Systems
Verified
Journal Article
Open access
NHNikosHatziargyriou Hatziargyriou
NikosHatziargyriou Hatziargyriou
JMJovica Milanovic
Jovica Milanovic
CRClaudia Rahmann
Claudia Rahmann
VAVenkataramana Ajjarapu
Venkataramana Ajjarapu
CCClaudio Canizares
Claudio Canizares
CVCostas Vournas
Costas Vournas
Since the publication of the original paper on power system stability definitions in 2004, the dynamic behavior of power systems has gradually changed due to the increasing penetration of converter interfaced generation technologies, loads, and transmission devices. In recognition of this change, a Task Force was established in 2016 to re-examine and extend, where appropriate, the classic definitions and classifications of the basic stability terms to incorporate the effects of fast-response power electronic devices. This paper based on an IEEE PES report summarizes the major results of the work of the Task Force and presents extended definitions and classification of power system stability.

30 September 2014 in Energies
Verified
Journal Article
Open access
PDF file
CRClaudia Rahmann
Claudia Rahmann
ACAlfredo Castillo
Alfredo Castillo
In recent years, only a small number of publications have been presented addressing power system stability with the increased use of large-scale photovoltaic (PV) generation around the world. The focus of these publications was on classical stability problems, such as transient and small signal stability, without considering frequency stability. Nevertheless, with increased PV generation, its effects on system frequency response during contingencies can no longer be ignored, especially in the case of weakly interconnected networks or isolated power systems. This paper addresses the impacts of large scale PV generation on the frequency stability of power systems. The positive effects of deloaded PV power plants (PV-PPs) able to support system frequency recovery during the initial seconds after major contingencies are also examined. Because this type of frequency support is not covered by current definitions, a new terminology is proposed that includes the frequency response of inertia-less generation units immediately after major power imbalances. We refer to this type of frequency support as fast frequency response (FFR). Finally, a discussion is also presented regarding the applicability and pertinence of frequency-related grid requirements for PV-PPs in the case of real power systems. The investigation is based on the isolated power system of northern Chile. The obtained results indicate that in the case of major power imbalances, no significant effects arise on the system frequency response until PV penetration levels exceed approximately 20%. From a system security perspective, the problems arise for PV penetration levels of approximately 50%, in which case, the frequency response capability in PV-PPs would be justified during certain hours of the year.

29 June 2021 in Processes
Verified
Journal Article
Open access
PDF file
ABAbdel Hady Badawy
Abdel Hady Badawy
Salah KamelSalah Kamel
Salah Kamel
Mohamed Hosny HassanMohamed Hosny Hassan
Mohamed Hosny Hassan
Tahir KhurshaidTahir Khurshaid
Tahir Khurshaid
CRClaudia Rahmann
Claudia Rahmann
Clean energy resources have become a worldwide concern, especially photovoltaic (PV) energy. Solar cell modeling is considered one of the most important issues in this field. In this article, an improvement for the search steps of the bald eagle search algorithm is proposed. The improved bald eagle search (IBES) was applied to estimate more accurate PV model parameters. The IBES algorithm was applied for conventional single, double, and triple PV models, in addition to modified single, double, and triple PV models. The IBES was evaluated by comparing its results with the original BES through 15 benchmark functions. For a more comprehensive analysis, two evaluation tasks were performed. In the first task, the IBES results were compared with the original BES for parameter estimation of original and modified tribe diode models. In the second task, the IBES results were compared with different recent algorithms for parameter estimation of original and modified single and double diode models. All tasks were performed using the real data for a commercial silicon solar cell (R.T.C. France). From the results, it can be concluded that the results of the modified models were more accurate than the conventional PV models, and the IBES behavior was better than the original BES and other compared algorithms.

7 September 2022 in Neural Computing and Applications
Verified
Journal Article
Closed access
PDF file
MKMansur Khasanov
Mansur Khasanov
Salah KamelSalah Kamel
Salah Kamel
Essam Halim HousseinEssam Halim Houssein
Essam Halim Houssein
CRClaudia Rahmann
Claudia Rahmann
FHFatma A. Hashim
Fatma A. Hashim

5 November 2020 in IEEE Access
Verified
Journal Article
Open access
DODiego Edmundo Ortiz
Diego Edmundo Ortiz
CRClaudia Rahmann
Claudia Rahmann
RARicardo Alvarez
Ricardo Alvarez
CCClaudio A. Canizares
Claudio A. Canizares
CSChristoph Strunck
Christoph Strunck
CCC. Caqizares
C. Caqizares
The transition from power systems dominated by synchronous machines to systems based on converter-based generation technologies (CGTs), is weakening currently robust power systems by reducing system inertia with the replacement of synchronous generators with low-inertia CGTs. From a frequency stability viewpoint, this is resulting in faster frequency dynamics and more frequent and larger frequency excursions after system contingencies, thus significantly affecting the stability of power systems dominated by CGTs, requiring detailed stability assessments to ensure the secure integration of CGTs. In this paper, a practical framework is presented for frequency stability studies based on time domain simulations of power systems with CGTs. A fundamental part of the proposed approach is the use of a filter to first identify worst-case scenarios among various possible system operating conditions. Once these worst-case scenarios are identified, a clustering technique is used to select representative worst-case operating conditions to evaluate the frequency stability of the system using time-domain simulations. The effectiveness of the proposed framework is demonstrated on the Chilean Northern Interconnected System (NIS), where it is shown that the proposed filter is able to quickly identify worst-case scenarios for further study. Moreover, we show that the selected representative operating conditions cover a wide-range of worst-case frequency responses, demonstrating the effectiveness of the proposed tool for frequency stability analyses.

22 June 2017 in Energies
Verified
Journal Article
Open access
PDF file
CRClaudia Rahmann
Claudia Rahmann
BMBenjamin Mac-Clure
Benjamin Mac-Clure
VVVijay Vittal
Vijay Vittal
FVFelipe Valencia
Felipe Valencia
In the last few years, several investigations have been carried out in the field of optimal sizing of energy storage systems (ESSs) at both the transmission and distribution levels. Nevertheless, most of these works make important assumptions about key factors affecting ESS profitability such as efficiency and life cycles and especially about the specific costs of the ESS, without considering the uncertainty involved. In this context, this work aims to answer the question: what should be the costs of different ESS technologies in order to make a profit when considering peak shaving applications? The paper presents a comprehensive sensitivity analysis of the interaction between the profitability of an ESS project and some key parameters influencing the project performance. The proposed approach determines the break-even points for different ESSs considering a wide range of life cycles, efficiencies, energy prices, and power prices. To do this, an optimization algorithm for the sizing of ESSs is proposed from a distribution company perspective. From the results, it is possible to conclude that, depending on the values of round trip efficiency, life cycles, and power price, there are four battery energy storage systems (BESS) technologies that are already profitable when only peak shaving applications are considered: lead acid, NaS, ZnBr, and vanadium redox.