Mattia Dimitri

Dr. Mattia Dimitri

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 November 2018 in International Journal of Hyperthermia
Verified
Journal Article
Open access
MDMattia Dimitri
Mattia Dimitri
Fabio StaderiniFabio Staderini
Fabio Staderini
MBMargherita Brancadoro
Margherita Brancadoro
FFFrancesco Frosini
Francesco Frosini
ACAndrea Coratti
Andrea Coratti
GGGuido Biffi Gentili
Guido Biffi Gentili
Purpose: Bleeding from parenchyma transection during a robotic hepatic surgery remains the most critical point affecting postoperative recovery and long-term survival. Various robotic devices with different types of energies have been proposed; however, each of these lack in steerability, efficacy, or accuracy. The aim of this work is to evaluate the feasibility and performance of a new steerable microwave resection device intended for minimizing intraoperative blood loss during laparoscopic and robotic liver resections. Methods: The new device operating at 2.45 GHz was designed to accommodate the engineering constraints derived from its use for robotic surgery or laparoscopy, in which a steerable head is required and the internal cooling of forced gas or water is undesirable. The device design, analysis, and optimization were addressed using the most advanced commercial electromagnetic and thermal solvers to achieve the best results. To experimentally validate the results of the numerical analysis, many ablations were performed on a freshly explanted bovine liver by using a single device prototype with three levels of energy supplied to the tissue. During the ablation procedures, the time, temperature, and shape of the thermal lesion were recorded using thermocouples and an infra-red thermos camera. Summary: Ex vivo tests showed good agreement with the numerical simulations, demonstrating the validity of the simplifications adopted to deal with the complex phenomena involved in the extreme hyperthermia of a living tissue. The high performance, thermal reliability, and robustness of the developed device were also demonstrated along with the possibility of reducing operation time and blood loss.

1 September 2018
Verified
Conference Paper
Closed access
GPGennadiy Pochanin
Gennadiy Pochanin
VRVadym Ruban
Vadym Ruban
TOTetiana Ogurtsova
Tetiana Ogurtsova
OOOleksandr Orlenko
Oleksandr Orlenko
IPIryna Pochanina
Iryna Pochanina
FCFronefield Crawford
Fronefield Crawford
The modern world is characterized by the pervasive use of computers, sensors, robotics, and Internet connectivity. This represents a new industrial revolution, dubbed Industry 4.0. In this paper, we discuss the application of the Industry 4.0 paradigm to creating a robotic search-and-detection platform intended for humanitarian demining. This is based on the combination and interaction of two microwave radars - including a UWB multi-sensor array, and a holographic imager - as well as 3-D optical cameras, remote navigation, and GPS tracking. The concepts introduced by Industry 4.0 represent an important opportunity for the scientific community to adopt new approaches in the design and use of UWB radar systems, and how data from these systems can be shared, archived, and processed in a decentralized manner accessible to the worldwide community

1 June 2018
Verified
Conference Paper
Closed access
TBT. Bechtel
T. Bechtel
GPGennadiy Pochanin
Gennadiy Pochanin
STS. Truskavetsky
S. Truskavetsky
MDMattia Dimitri
Mattia Dimitri
VRV. Ruban
V. Ruban
Lorenzo CapineriLorenzo Capineri
Lorenzo Capineri
We are designing and building a multi-sensor semi-autonomous vehicle to assist in humanitarian demining in the Donbass conflict zone, Ukraine. The vehicle will carry impulse GPR for fast target detection, and holographic GPR for discrimination of mines from clutter. The design includes the possibility to add additional sensor. To ensure that the vehicle is compatible with actual Donbass conditions, the COTS dimensions of the selected vehicle (Clearpath Robotics “Jackal”), and relief profiles from two transects collected on the edge of the conflict zone, were compared using morphological filtering terrain analysis. The analysis shows that the vehicle can traverse the recorded transects with no threat of nose-in failure, and minimal threat of hang-up failure. Preliminary testing of the holographic radar mounted on the vehicle show that it can effectively image the footprint of mine-like targets, with resolution of a little more than one centimeter.

6 January 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MRMartina Ricci
Martina Ricci
EBElisa Barbi
Elisa Barbi
MDMattia Dimitri
Mattia Dimitri
Claudia DurantiClaudia Duranti
Claudia Duranti
Annarosa ArcangeliAnnarosa Arcangeli
Annarosa Arcangeli
ACAndrea Corvi
Andrea Corvi
Sonoporation has garnered significant attention for its potential to temporarily permeabilize cell membranes through the application of ultrasound waves, thus enabling an efficient cellular uptake of molecules. Despite its promising applications, the precise control of sonoporation remains a complex and evolving challenge in the field of cellular and molecular biology. This review aims to address two key aspects central to advancing our understanding of sonoporation. Firstly, it underscores the necessity for the establishment of a standardized methodology to validate and quantify the successful entry of molecules into target cells. This entails a critical examination of existing techniques and the identification of best practices to ensure accurate, reliable, and reproducible results. By establishing a common framework for assessing sonoporation outcomes, researchers can enhance the reliability and comparability of their experiments, paving the way for more robust findings. Secondly, the review places particular emphasis on the detailed analysis of various acoustic parameters as reported in the papers selected from the literature. Among these parameters, acoustic intensity (specifically, ISPTA) emerges as a pivotal factor in sonoporation studies. Furthermore, this review delves into the exploration of the elastic modulus and its significance in sonoporation mechanisms and associated challenges. This knowledge can inform the development of more effective strategies to optimize sonoporation protocols. In summary, this review not only highlights the pressing need for a standardized approach to verify molecule entry into cells but also delves into the search for an effective frequency and acoustic intensity for in vivo and in vitro applications.

11 January 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MDMattia Dimitri
Mattia Dimitri
Claudia DurantiClaudia Duranti
Claudia Duranti
SASara Aquino
Sara Aquino
LMLucrezia Mazzantini
Lucrezia Mazzantini
JIJessica Iorio
Jessica Iorio
ACAndrea Corvi
Andrea Corvi
Current developments in medical technology have focused on therapeutic treatments that selectively and effectively address specific pathological areas, minimizing side effects on healthy tissues. In this regard, many procedures have been developed to provide non-invasive therapy, for example therapeutic ultrasound (US). In the medical field, in particular in cancer research, it has been observed how ultrasounds can cause cell death and inhibit cell proliferation of cancer cells, while preserving healthy ones with almost negligible side effects. Various studies have shown that low intensity pulse ultrasound (LIPUS) and low intensity continuous ultrasound (LICUS) regulate the proliferation, cell differentiation and cavitation phenomena. Nowadays, there are poorly known aspects of low intensity US treatment, in terms of biophysical and biomechanical effects on target cells. The aim of this study is to set up an innovative apparatus for US treatment of pancreatic ductal adenocarcinoma (PDAC) cells, monitoring parameters such as acoustic intensity, acoustic pressure, stimulation frequency and treatment protocol. To this purpose, we have developed a custom-made set up for the US stimulation at 1.2 and 3 MHz of tridimensional (3D) cultures of PDAC cells (PANC-1, Mia Paca-2 and BxPc3 cells). Images of the 3D cultures were acquired, and the Calcein/PI assay was applied to detect US-induced cell death. Overall, the setup we have presented paves the way to an innovative protocol for tumor treatment. The system can be used either alone or in combination with small molecules or recombinant antibodies in order to propose a novel combined therapeutic approach.

7 April 2020 in Minimally Invasive Therapy & Allied Technologies
Verified
Journal Article
Closed access
MBMargherita Brancadoro
Margherita Brancadoro
MDMattia Dimitri
Mattia Dimitri
MBMohamed Nassim Boushaki
Mohamed Nassim Boushaki
Fabio StaderiniFabio Staderini
Fabio Staderini
ESEdoardo Sinibaldi
Edoardo Sinibaldi
AMArianna Menciassi
Arianna Menciassi
Introduction: During the last two decades, many surgical procedures have evolved from open surgery to minimally invasive surgery (MIS). This limited invasiveness has motivated the development of robotic assistance platforms to obtain better surgical outcomes. Nowadays, the da Vinci robot is a commercial tele-robotic platform widely used for different surgical applications. Material and methods: In this work, the da Vinci Research Kit (dVRK), namely the research version of the da Vinci, is used to manipulate a novel microwave device in a teleoperation scenario. The dVRK provides an open source platform, so that the novel microwave tool, dedicated to prevention bleeding during hepatic resection surgery, is mechanically integrated on the slave side, while the software interface is adapted in order to correctly control tool pose. Tool integration is validated through in-vitro and ex-vivo tests performed by expert surgeons, meanwhile the coagulative efficacy of the developed tool in a perfused liver model was proved in in-vivo tests. Results and conclusions: An innovative microwave tool for liver robotic resection has been realized and integrated into a surgical robot. The tool can be easily operated through the dVRK without limiting the intuitive and friendly use, and thus easily reaching the hemostasis of vessels.