Xu Yiwei

Dr. Xu Yiwei

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 September 2024 in Food Chemistry: X
Verified
Journal Article
Open access
XYXu Yiwei
Xu Yiwei
JXJia Xupeng
Jia Xupeng
YSYang Sennan
Yang Sennan
CMCao Mengrui
Cao Mengrui
BHBaoshan He
Baoshan He
SZSuo Zhiguang
Suo Zhiguang
An aptasensor with dual-outputs was developed for malathion detection. Fe-MOF was synthesized to design favorable signal probes for catalytic amplification. Owing to the excellent peroxidase-like activity of Fe-MOF, the redox reaction was catalyzed to produce the dual-outputs of colorimetric and electrochemical. In this sensing strategy, malathion was captured by the aptamer on sensing interface, leading to the release of signal probe. Thanks to the catalytic amplification of Fe-MOF and the high capture effect of aptamer, the aptasensor produced a sensitive response for malathion. Based on the dual-signals of absorbance and current, the detection method for malathion was developed ranging from 10 ng/mL to 500 ng/mL. The detection limit of malathion was 5.8 ng/mL for colorimetric output and 4.6 ng/mL for electrochemical output. Furthermore, the aptasensor exhibited high specificity and good repeatability in malathion detection. Finally, the aptasensor was applied to detect malathion in fruit and vegetable samples with satisfactory recovery.

10 July 2024 in Foods
Verified
Journal Article
Open access
PDF file
XYXu Yiwei
Xu Yiwei
XJXupeng Jia
Xupeng Jia
SYSennan Yang
Sennan Yang
MCMengrui Cao
Mengrui Cao
BHBaoshan He
Baoshan He
ZSZhi-Guang Suo
Zhi-Guang Suo
A novel electrochemical aptasensor was prepared for the simultaneous determination of aflatoxin B1 (AFB1) and ochratoxin A (OTA). Composites of Au nanoparticles and polyethyleneimine-reduced graphene oxide (AuNPs/PEI-RGO) with good electrical conductivity and high specific surface area were employed as the supporting substrate, demonstrating the ability to provide more binding sites for aptamers and accelerate the electron transfer. Aptamers were immobilized on a AuNPs/PEI-RGO surface to specifically recognize AFB1 and OTA. A metal–organic framework of UiO-66-NH2 served as the signal carrier to load metal ions of Cu2+ and Pb2+, which facilitated the generation of independent current peaks and effectively improved the electrochemical signals. The prepared aptasensor exhibited sensitive current responses for AFB1 and OTA with a linear range of 0.01 to 1000 ng/mL, with detection limits of 6.2 ng/L for AFB1 and 3.7 ng/L for OTA, respectively. The aptasensor was applied to detect AFB1 and OTA in cereal samples, achieving results comparable with HPLC-MS, with recovery results from 92.5% to 104.1%. With these merits of high sensitivity and good selectivity and stability, the prepared aptasensor proved to be a powerful tool for evaluating contaminated cereals.

12 February 2024 in Journal of Food Measurement and Characterization
Verified
Journal Article
Closed access
PDF file
MCMengrui Cao
Mengrui Cao
XYXu Yiwei
Xu Yiwei
XJXupeng Jia
Xupeng Jia
BHBaoshan He
Baoshan He
WRWenjie Ren
Wenjie Ren
WZWenhong Zhao
Wenhong Zhao

9 May 2026 in Bioelectrochemistry
Verified
Journal Article
Closed access
HWHuang Wei
Huang Wei
XYXu Yiwei
Xu Yiwei
GYGuo Yaojie
Guo Yaojie
CDChen Dingyao
Chen Dingyao
RWRen Wenjie
Ren Wenjie
HBHe Baoshan
He Baoshan