Naoki Sugiyama

Naoki Sugiyama


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2024 in Geriatrics
Verified
Journal Article
Open access
PDF file
NSNaoki Sugiyama
Naoki Sugiyama
YKYoshihiro Kai
Yoshihiro Kai
HKHitoshi Koda
Hitoshi Koda
TMToru Morihara
Toru Morihara
NKNoriyuki Kida
Noriyuki Kida
Postural assessment is one of the indicators of health status in older adults. Since the number of older adults is on the rise, it is essential to assess simpler methods and automated ones in the future. Therefore, we focused on a visual method (imaging method). The purpose of this study is to determine the degree of agreement between the imaging method and the palpation and visual methods (clinical method). In addition, the influence of differences in the information content of the sagittal plane images on the assessment was also investigated. In this experiment, 28 sagittal photographs of older adults whose posture had already been assessed using the clinical method were used. Furthermore, based on these photographs, 28 gray and silhouette images (G and S images) were generated, respectively. The G and S images were assessed by 28 physical therapists (PTs) using the imaging method. The assessment was based on the Kendall classification, with one of four categories selected for each image: ideal, kyphosis lordosis, sway back, and flat back. Cross-tabulation matrices of the assessments using the clinical method and imaging method were created. In this table, four categories and two categories of ideal and non-ideal (KL, SB, and FB) were created. The agreement was evaluated using the prevalence-adjusted bias-adjusted kappa (PABAK). In addition, sensitivity and specificity were calculated to confirm the reliability. When comparing the clinical and imaging methods in the four posture categories, the PABAK values were −0.14 and −0.29 for the S and G images, respectively. In the case of the two categories, the PABAK values were 0.57 and 0.5 for the S and G images, respectively. The sensitivity and specificity were 86% and 57% for the S images and 76% and 71% for the G images, respectively. The four categories show that the imaging method is difficult to assess regardless of the image processing. However, in the case of the two categories, the same assessment of the clinical method applied to the imaging method for both the S and G images. Therefore, no differences in image processing were observed, suggesting that PTs can identify posture using the visual method.

19 March 2025 in Geriatrics
Verified
Journal Article
Open access
PDF file
NSNaoki Sugiyama
Naoki Sugiyama
YKYoshihiro Kai
Yoshihiro Kai
HKHitoshi Koda
Hitoshi Koda
TMToru Morihara
Toru Morihara
NKNoriyuki Kida
Noriyuki Kida
Background/Objectives: Posture is a significant indicator of health status in older adults. This study aimed to develop an automatic posture assessment tool based on sagittal photographs by validating recognition models using convolutional neural networks. Methods: A total of 9140 images were collected with data augmentation, and each image was labeled as either Ideal or Non-Ideal posture by physical therapists. The hidden and output layers of the models remained unchanged, while the loss function and optimizer were varied to construct four different model configurations: mean squared error and Adam (MSE & Adam), mean squared error and stochastic gradient descent (MSE & SGD), binary cross-entropy and Adam (BCE & Adam), and binary cross-entropy and stochastic gradient descent (BCE & SGD). Results: All four models demonstrated an improved accuracy in both the training and validation phases. However, the two BCE models exhibited divergence in validation loss, suggesting overfitting. Conversely, the two MSE models showed stability during learning. Therefore, we focused on the MSE models and evaluated their reliability using sensitivity, specificity, and Prevalence-Adjusted Bias-Adjusted Kappa (PABAK) based on the model’s output and correct label. Sensitivity and specificity were 85% and 84% for MSE & Adam and 67% and 77% for MSE & SGD, respectively. Moreover, PABAK values for agreement with the correct label were 0.69 and 0.43 for MSE & Adam and MSE & SGD, respectively. Conclusions: Our findings indicate that the MSE & Adam model, in particular, can serve as a useful tool for screening inspections.