Wenlong Li

Dr. Wenlong Li


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2022 in Disease Markers
Verified
Journal Article
Open access
PDF file
ZSZhengze Sun
Zhengze Sun
YLYaxin Li
Yaxin Li
RLRongjun Liu
Rongjun Liu
BMBaikai Ma
Baikai Ma
YZYifan Zhou
Yifan Zhou
HQHong Qi
Hong Qi
Bulbar conjunctival microcirculation is a microvascular system distributed in the translucent bulbar conjunctiva near the corneal limbus. Multiple ocular diseases lead to bulbar conjunctival microcirculation alterations, which means that bulbar conjunctival microcirculation alterations would be potential screening and diagnostic indicators for these ocular diseases. In recent years, with the emergence and application of a variety of noninvasive observation devices for bulbar conjunctiva microcirculation and new image processing technologies, studies that explored the potential of bulbar conjunctival microcirculation alterations in the diagnosis of ocular diseases have been emerging. However, the potential of bulbar conjunctival microcirculation alterations as indicators for ocular diseases has not been exploited to full advantage. The observation devices, image processing methods, and algorithms are not unified. And large-scale research is needed to concrete bulbar conjunctival microcirculation alterations as indicators for ocular diseases. In this paper, we provide an update on the progress of bulbar conjunctival microcirculation alterations in the diagnosis of ocular diseases in recent five years (from January 2017 to March 2022). Relevant ocular diseases include contact lens wearing, dry eye, conjunctival malignant melanoma, conjunctival nevus, and diabetic retinopathy.

5 January 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
WLWenlong Li
Wenlong Li
LBLinbo Bian
Linbo Bian
BMBaikai Ma
Baikai Ma
TSTong Sun
Tong Sun
YLYiyun Liu
Yiyun Liu
HQHong Qi
Hong Qi
Diabetic retinopathy (DR), retinal vein occlusion (RVO), and age-related macular degeneration (AMD) pose significant global health challenges, often resulting in vision impairment and blindness. Automatic detection of these conditions is crucial, particularly in underserved rural areas with limited access to ophthalmic services. Despite remarkable advancements in artificial intelligence, especially convolutional neural networks (CNNs), their complexity can make interpretation difficult. In this study, we curated a dataset consisting of 15,089 color fundus photographs (CFPs) obtained from 8110 patients who underwent fundus fluorescein angiography (FFA) examination. The primary objective was to construct integrated models that merge CNNs with an attention mechanism. These models were designed for a hierarchical multilabel classification task, focusing on the detection of DR, RVO, AMD, and other fundus conditions. Furthermore, our approach extended to the detailed classification of DR, RVO, and AMD according to their respective subclasses. We employed a methodology that entails the translation of diagnostic information obtained from FFA results into CFPs. Our investigation focused on evaluating the models’ ability to achieve precise diagnoses solely based on CFPs. Remarkably, our models showcased improvements across diverse fundus conditions, with the ConvNeXt-base + attention model standing out for its exceptional performance. The ConvNeXt-base + attention model achieved remarkable metrics, including an area under the receiver operating characteristic curve (AUC) of 0.943, a referable F1 score of 0.870, and a Cohen’s kappa of 0.778 for DR detection. For RVO, it attained an AUC of 0.960, a referable F1 score of 0.854, and a Cohen’s kappa of 0.819. Furthermore, in AMD detection, the model achieved an AUC of 0.959, an F1 score of 0.727, and a Cohen’s kappa of 0.686. Impressively, the model demonstrated proficiency in subclassifying RVO and AMD, showcasing commendable sensitivity and specificity. Moreover, our models enhanced interpretability by visualizing attention weights on fundus images, aiding in the identification of disease findings. These outcomes underscore the substantial impact of our models in advancing the detection of DR, RVO, and AMD, offering the potential for improved patient outcomes and positively influencing the healthcare landscape.

9 February 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
LBLinbo Bian
Linbo Bian
WLWenlong Li
Wenlong Li
RQRui Qin
Rui Qin
ZSZhengze Sun
Zhengze Sun
LZLu Zhao
Lu Zhao
HQHong Qi
Hong Qi
Objectives: The study aims to explore the ocular biometry of a myopic population in Northern China, focusing specifically on anterior and posterior segment lengths. Methods: This is a cross-sectional study. The medical records of 3458 myopic patients who underwent refractive surgery were evaluated. Axial length (AL), anterior chamber depth (ACD), lens thickness (LT) and other biometric parameters were measured using the IOL Master 700. The study determined the anterior segment length (ASL = ACD + LT), the posterior segment length (PSL = AL − ASL) and the ratio of ASL to PSL (ASL/PSL). Results: This study included 3458 eyes from 3458 myopic patients (1171 men and 2287 women). The mean age was 27.38 ± 6.88, ranging from 16 to 48 years old. The mean ASL was 7.35 ± 0.27 mm, and the mean PSL was 18.39 ± 1.18 mm. The ASL and PSL trends demonstrate an age-related increase for both genders, with notable gender-specific variations. Across most age groups, males typically exhibited higher ASLs and PSLs than females, with the exception of the 35–40 and 40–45 age groups. The ASL and PSL consistently increased with a rising AL. The AL strongly correlates with the PSL and negatively correlates with the ASL/PSL ratio. The ACD and LT moderately correlate with the ASL, but an increased LT does not imply a longer posterior segment. The CCT and SE show little correlation with axial eye parameters. Conclusions: Among Chinese myopic patients, a longer ASL and PSL were correlated with older age and the male gender. The AL strongly correlates positively with the PSL and negatively correlates with the ASL/PSL ratio. An elongation of the posterior segment may primarily account for an eyeball’s lengthening.

26 October 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
DLDehai Liu
Dehai Liu
RQRui Qin
Rui Qin
YLYiyun Liu
Yiyun Liu
SLSiyuan Liu
Siyuan Liu
LHLanxin Hu
Lanxin Hu
WLWenlong Li
Wenlong Li
Background/Objectives: To compare preoperative clinical and biometric characteristics between primary angle-closure disease (PACD) eyes with intraoperatively identified zonulopathy and their fellow eyes, and to explore interdevice measurement differences. Methods: This single-center paired-eye study included 57 patients with PACD undergoing bilateral cataract surgery and unilateral intraoperatively identified zonulopathy. Preoperative measurements were obtained using IOLMaster, Pentacam, and ultrasound biomicroscopy (UBM). Paired outcomes were compared using Wilcoxon signed-rank or exact McNemar tests, with Benjamini–Hochberg correction applied separately to clinical and biometric comparisons. Results: Eyes with zonulopathy more frequently had primary angle-closure glaucoma and previous acute angle-closure (AAC) attacks, greater angle-closure extent, and more severe mean deviation-based visual-field loss. These eyes had shallower corrected IOLMaster anterior chamber depth (ACD; 1.50 ± 0.40 versus 1.82 ± 0.35 mm), lower lens position (4.03 ± 0.33 versus 4.37 ± 0.28 mm), and smaller anterior chamber volume (59.9 ± 24.0 versus 75.4 ± 22.8 mm³; all q < 0.001). UBM minus IOLMaster ACD, UBM minus Pentacam ACD, and Pentacam minus UBM pupil diameter differed significantly between paired eyes (q = 0.002, 0.017, and 0.023, respectively). Conclusions: PACD eyes with occult zonulopathy showed a shallower anterior chamber, lower lens position, smaller anterior chamber volume, and greater interdevice differences in selected ACD and pupil measurements. These exploratory associations require validation before their use for preoperative identification of zonulopathy.

7 November 2026 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
WLWenlong Li
Wenlong Li
WZWei Zhou
Wei Zhou
XYXuekun Yang
Xuekun Yang
JQJun Qiang
Jun Qiang
HQHong Qi
Hong Qi
QYQifeng Yan
Qifeng Yan