Juan L. Bellido

Dr. Juan L. Bellido

SiCtech Induction, Valencia, Spain
orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2024 in Electronics
Verified
Journal Article
Open access
PDF file
Vicente Esteve GomezVicente Esteve Gomez
Vicente Esteve Gomez
Juan L. BellidoJuan L. Bellido
Juan L. Bellido
JJJosé Jordán
José Jordán
EDEnrique J. Dede
Enrique J. Dede
This article presents a control method for an isolated bidirectional dual active bridge DC–DC converter (IBDC) where single phase shift (SPS) and variable frequency (VF) modulations are combined simultaneously with the purpose of improving the efficiency of the converter applied to the bidirectional charging of electric vehicles batteries. A complete power characterization of the dual active bridge (DAB) converter is carried out. The combined control achieves lossless turn-on and turn-off on the primary bridge for a wide range of output powers. A comparative study of power losses between the traditional SPS control and the combined method proposed here was also carried out. A prototype with an output power of 10 kW was built based on Silicon Carbide (SiC) Metal Oxide Semiconductor Field-Effect Transistors (MOSFET), with which a peak efficiency close to 99% was obtained, thus verifying the viability of the method.

1 July 2024 in Electronics
Verified
Journal Article
Open access
PDF file
Vicente Esteve GomezVicente Esteve Gomez
Vicente Esteve Gomez
Juan L. BellidoJuan L. Bellido
Juan L. Bellido
JJJosé Jordán
José Jordán
Induction surface hardening (ISH) processes are widely used in the heat treatment of numerous industrial components, especially in the automotive industry. Since this industry operates under very demanding quality standards, it is crucial for these heat treatment processes to meet rigorous specifications to ensure the safety and reliability of the produced components. This implies the precise and repeatable control of certain parameters throughout the manufacturing process of each of the parts treated, through precise and reliable instrumentation in electromagnetically harsh environments. The main objective of this work is to define the monitoring process for an industrial IHS application, determining the control needs and the methods of measurement, recording, and verification of the parameters that ensure the quality of the process. This paper describes the monitoring process of induction surface hardening, emphasizing the use of sensors and modern measurement and control systems. A comprehensive monitoring system supported by a programmable logic controller (PLC) and mixed acquisition and instrumentation systems (analog and digital) implemented with a high-performance Field Programmable Gate Array (FPGA) will be presented.

19 March 2025 in Electronics
Verified
Journal Article
Open access
PDF file
Vicente Esteve GomezVicente Esteve Gomez
Vicente Esteve Gomez
JJJosé Jordán
José Jordán
Juan L. BellidoJuan L. Bellido
Juan L. Bellido
This paper reviews the current state of research on half-bridge (HB) inverters used in induction heating power supplies, emphasizing their topological structures, output power control methods, and switching strategies. The study explores various control techniques to regulate low power levels in a series resonant inverter (SRI) configured with an HB structure for induction heating applications. Pulse frequency modulation (PFM) is commonly employed to regulate standard power levels by adjusting the operating frequency relative to the resonant frequency. As the operating frequency increases beyond resonance, the output power decreases. However, in certain scenarios, achieving low power levels necessitates high frequencies, which introduces significant control challenges. To address these issues, it is crucial to develop alternative approaches that ensure efficient power reduction, without compromising system performance. This work evaluates and compares multiple solutions tailored for a high-frequency induction heating system delivering 18 kW at an operating frequency of approximately 100 kHz. The study places particular emphasis on optimizing key component sizing and analyzing inverter losses to enhance overall system efficiency and reliability.

7 March 2024 in Energies
Verified
Journal Article
Open access
PDF file
Vicente Esteve GomezVicente Esteve Gomez
Vicente Esteve Gomez
Juan L. BellidoJuan L. Bellido
Juan L. Bellido
JJJosé Jordán
José Jordán
This article outlines the comprehensive design and control approach for a single-phase bidirectional rectifier (SPBR) used in bidirectional charging of electric vehicle batteries. The operational parameters of the inverter are determined through a thorough analysis of all switching sequences to accurately assess power losses, considering the type of switching device chosen in each case, enabling proper component sizing, and understanding converter efficiency. An exclusive electronic control circuit is examined, governing two converter operation modes: boost rectifier with power factor correction (PFC) and sine pulse inverter width modulation (SPWM) with a minimum number of adjustments made automatically. One problem that arises when addressing the design of an SPBR is determining the operating frequency. To address this issue, this study offers to conduct a comparative analysis of losses using various power devices and magnetic circuits to determine the optimal operating frequency for achieving maximum energy efficiency. To validate the design’s feasibility, a prototype with 10 kW output power was constructed, achieving a peak efficiency of approximately 97.5% in both directions, unity power factor (PF), and total harmonic distortion (THD) of less than 7% during full power operation.

2 July 2024 in Electronics
Verified
Journal Article
Open access
PDF file
Juan L. BellidoJuan L. Bellido
Juan L. Bellido
Vicente Esteve GomezVicente Esteve Gomez
Vicente Esteve Gomez
JJJosé Jordán
José Jordán
This paper presents a comprehensive analysis of a novel control approach to improve the efficiency of parallel LLC resonant inverters using a combination of a current controlled variable inductor (VI) and phase shift (PS). The proposed control aims to reduce the Root Mean Square (RMS) current, thereby reducing conduction and switching losses, and improving power transfer efficiency, while considering zero-voltage-switching (ZVS) operation, output power variations and load changes. Furthermore, a design methodology for the variable inductor is proposed, and design considerations relevant to this application are discussed. The effectiveness of the proposed approach is evaluated through mathematical modeling and experimental results. The mathematical modeling results show that the proposed approach, utilizing SiC MOSFETs, maintains a maximum efficiency of 98.5% for a 20 kW inverter over a wider range of output power, which is a significant improvement over existing approaches. The experimental results also confirm the effectiveness of the proposed control in improving the efficiency of parallel LLC resonant inverters.

25 November 2025 in Electronics
Verified
Journal Article
Open access
PDF file
MVMattia Vogni
Mattia Vogni
Juan L. BellidoJuan L. Bellido
Juan L. Bellido
FSFausto Stella
Fausto Stella
LSLeonardo Stefanini
Leonardo Stefanini
Claudio BianchiniClaudio Bianchini
Claudio Bianchini
Vicente Esteve GomezVicente Esteve Gomez
Vicente Esteve Gomez
The growing market penetration of Electric Vehicles (EVs) requires very efficient bidirectional on-board chargers. These converters must allow the power transfer from the grid to the battery of the vehicle and vice versa, since Vehicle to Grid (V2G) applications enable a mitigation of the peak demand and help regulate both the voltage and the frequency of the grid. In this paper, an innovative double asymmetric modulation was studied and applied to a resonant Dual Active Bridge (DAB), CLLC resonant filter configuration. The results of the study showed a significant efficiency boost and an easier controllability of the converter with respect to more traditional modulations or variable frequency techniques, maintaining Zero-Voltage Switching (ZVS) conditions for all the switches in a wide operating range, from 28 to 100% of the maximum power (4–14 kW). A map of optimum points, where converter losses are minimized, is calculated offline through an algorithm in MATLAB R2024a and a proper interpolation between these points allows any output power for each possible voltage level of the battery to be achieved: from 250 V up to 400 V. The modulations are compared and evaluated through simulations carried out in PLECS, both offline and using hardware-in-the-loop (HIL), as well as through experimental tests.