Claudio Bianchini

Dr. Claudio Bianchini

Department of Engineering (DIEF), University of Modena and Reggio Emilia, 41121 Modena, Italy
orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2012 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Fabio ImmovilliFabio Immovilli
Fabio Immovilli
Claudio BianchiniClaudio Bianchini
Claudio Bianchini
Marco CocconcelliMarco Cocconcelli
Marco Cocconcelli
Alberto BelliniAlberto Bellini
Alberto Bellini
RRRiccardo Rubini
Riccardo Rubini
This paper investigates the relationship between vibration and current in induction motors operated under external vibrations. Two approaches are usually available to define this relationship. The former is based on airgap variations, while the latter is based on torque perturbation. This paper is focused on the airgap variation model. The ball bearing fault is modeled by contact mechanics. External vibrations often occur in many industrial applications where externally induced vibrations of suitable amplitude cause cyclic radial loading on the machine shaft. The model is validated by experiments, owing to a dedicated test setup, where an external vibration source (shaker) was employed, together with ball bearing alterations in order to decrease the stiffness of the support along the radial direction. To maximize the effects of externally induced vibrations, the frequency chosen was near the flexural resonance of the rotor (determined by finite-element method analysis). The direction of the external vibration is radial with respect to the axis of the electric machine under test. During tests, both stator phase currents and vibration of the machine were sampled. The test setup allowed one to vary the machine speed and load, vibration amplitude, and bearing stiffness (damage level). Radial effects are usually visible only in the case of large failures that result in significant airgap variations, as confirmed by experiments.

10 December 2010 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Claudio BianchiniClaudio Bianchini
Claudio Bianchini
Fabio ImmovilliFabio Immovilli
Fabio Immovilli
Marco CocconcelliMarco Cocconcelli
Marco Cocconcelli
RRRiccardo Rubini
Riccardo Rubini
Alberto BelliniAlberto Bellini
Alberto Bellini
Electric linear motors are spreading in industrial automation because they allow for direct drive applications with very high dynamic performances, high reliability, and high flexibility in trajectory generation. The moving part of the motor is linked to the fixed part by means of linear bearings. As in many other electric machines, bearings represent one of the most vulnerable parts because they are prone to wear and contamination. In the case of linear roller bearings, this issue is even more critical as the rail cannot be easily fully enclosed and protected from environmental contamination, unlike the radial rotating bearing counterpart. This paper presents a diagnostic method based on vibration analysis to identify which signature is related to a specific fault.

15 May 2012 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
Claudio BianchiniClaudio Bianchini
Claudio Bianchini
Fabio ImmovilliFabio Immovilli
Fabio Immovilli
Emilio LorenzaniEmilio Lorenzani
Emilio Lorenzani
Alberto BelliniAlberto Bellini
Alberto Bellini
MDMatteo Davoli
Matteo Davoli
Internal permanent-magnet synchronous machines are spreading in industrial production. They feature high torque density and extended speed range that are key issues in many fields of applications, however their cogging torque is typically quite high. Many methods and design guidelines for cogging torque reduction exist in literature and this paper compares them. For this purpose, the different design guidelines are applied to a common reference machine in order to assess their effectiveness. Computer finite element analysis (FEA) are carried out for each case in order to compare the cogging torque reduction capability of the different techniques. The side effects of these techniques, such as back-EMF and rated torque profile distortions, will be taken into account. The paper contribution is to compare the various cogging torque reduction techniques and magnetic geometries on a common reference machine to identify the most effective ones.

23 February 2017 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
ELEmilio Lorenzani
Emilio Lorenzani
FIFabio Immovilli
Fabio Immovilli
Giovanni MigliazzaGiovanni Migliazza
Giovanni Migliazza
MFMatteo Frigieri
Matteo Frigieri
Claudio BianchiniClaudio Bianchini
Claudio Bianchini
MDMatteo Davoli
Matteo Davoli
This paper analyzes the performance of a grid-tied, wide power range, transformerless, modified three-phase current-source inverter (CSI), named CSI7. The CSI7 topology is here analyzed along with a suitable space vector modulation strategy able to attenuate the excitation of the output CL filter. The theoretical analysis and simple analytic expressions highlighted the performance and limitations of the topology when employed as a single-stage photovoltaic (PV) inverter, with a particular emphasis on injected grid current distortion and ground leakage current values. The inverter wide input range allows interfacing PV strings of different module count with a simple closed-loop control. The principle of operation and control is described; the viability of the CSI7 topology was assessed with simulations and extensive experiments on a full-size laboratory prototype.

19 August 2014 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Fabio ImmovilliFabio Immovilli
Fabio Immovilli
Claudio BianchiniClaudio Bianchini
Claudio Bianchini
Emilio LorenzaniEmilio Lorenzani
Emilio Lorenzani
Alberto BelliniAlberto Bellini
Alberto Bellini
EFEmanuele Fornasiero
Emanuele Fornasiero
This paper focuses on modeling and experimental validation of a diagnostic fault classification procedure for interturn fault detection in permanent-magnet (PM) multiphase machines designed for fault-tolerant electric drives. The diagnostic procedure is based on the symmetrical component theory and relies upon the combined space vector vector D that gathers information from the two original space vectors obtained with different reference frames. The diagnostic index effectiveness and robustness were also investigated against other fault types such as rotor eccentricities and magnet damage to assess its discrimination capability. The proposed procedure was experimentally evaluated for the interturn fault case on a five-phase PM machine. Experiments were carried out at different speed and load levels, with increasing numbers of short-circuited turns. Both simulation and experimental results demonstrated the feasibility of the proposed diagnostic method.

1 October 2021 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Claudio BianchiniClaudio Bianchini
Claudio Bianchini
ATAmbra Torreggiani
Ambra Torreggiani
DDDanilo David
Danilo David
Alberto BelliniAlberto Bellini
Alberto Bellini