David Mas

Prof. David Mas

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 1999 in Optics Communications
Verified
Journal Article
Closed access
DMDavid Mas
David Mas
JGJavier Garcia
Javier Garcia
CFCarlos Ferreira
Carlos Ferreira
LBLuis M. Bernardo
Luis M. Bernardo
FMFrancisco Marinho
Francisco Marinho

10 July 1997 in Applied Optics
Verified
Journal Article
Closed access
PDF file
DMDavid Mendlovic
David Mendlovic
ZZZeev Zalevsky
Zeev Zalevsky
DMDavid Mas
David Mas
JGJavier García
Javier García
CFCarlos Ferreira
Carlos Ferreira
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.

10 December 1996 in Applied Optics
Verified
Journal Article
Closed access
PDF file
JGJavier García
Javier García
DMDavid Mas
David Mas
RDRainer G. Dorsch
Rainer G. Dorsch
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.

15 November 2003 in Optics Communications
Verified
Journal Article
Closed access
DMDavid Mas
David Mas

1 August 1999 in Applied Optics
Verified
Journal Article
Closed access
PDF file
JEJosé J. Esteve-Taboada
José J. Esteve-Taboada
DMDavid Mas
David Mas
JGJavier García
Javier García
An automatic method for three-dimensional (3-D) shape recognition is proposed. It combines the Fourier transform profilometry technique with a real-time recognition setup such as the joint transform correlator (JTC). A grating is projected onto the object surface resulting in a distorted grating pattern. Since this pattern carries information about the depth and the shape of the object, their comparison provides a method for recognizing 3-D objects in real time. A two-cycle JTC is used for this purpose. Experimental results demonstrate the theory and show the utility of the new proposed method.

1 January 2007 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
DODolores Ortiz
Dolores Ortiz
JAJorge L. Alió
Jorge L. Alió
CICarlos Illueca
Carlos Illueca
DMDavid Mas
David Mas
ESEsperanza Sala
Esperanza Sala
Julián Espinosa Julián Espinosa
Julián Espinosa
Purpose: To evaluate the changes in the optical quality of corneas of hyperopic patients operated using central multifocal presbyLASIK treatment through the study of light patterns around the retinal plane. Methods: This study included eight hyperopic eyes that underwent central presbyLASIK surgery with Presby-one software using an H. Eye Tech Technovision excimer laser platform. Mean patient age was 57 years. Mean preoperative spherical equivalent refraction was 1.28±0.87 diopters (D). Mean distance decimal visual acuity with correction was 1.02±0.13 and without correction was 0.37±0.15. The optical quality was characterized by the Strehl ratio, the spot size on the retina, and objective decimal visual acuity calculated based on measured corneal topography using Fresnel propagation algorithm based on a realistic eye model. Results: The postoperative spherical equivalent refraction was −0.55±0.48 D. The distance decimal visual acuity with correction was 0.94 and without correction was 0.70. The pseudoaccommodation range was 1.60±0.40 D. A good Pearson correlation coefficient was obtained (r 2 =0.86) for the linear fit between the real and calculated decimal visual acuity for the eight eyes. The Strehl ratio value on the retinal plane increased after the surgery by a mean factor of 4.7. Conclusions: With a complete characterization of the eye and a complete propagation algorithm (that takes into account all refractive surfaces in the eye at the same time), it is possible to evaluate the optical quality in eyes of patients who have undergone central presbyLASIK treatment. [ J Refract Surg . 2007;23:39–44.]