Background and Purpose. Researchers studying central activation of muscles in elderly subjects (≥65 years of age) have investigated activation in only the nonfatigued state. This study examined the ability of young and elderly people to activate their quadriceps femoris muscles voluntarily under both fatigued and nonfatigued conditions to determine the effect of central activation failure on age-related loss of force. Subjects and Methods. Twenty young subjects (11 men, 9 women; mean age=22.67 years, SD=4.14, range=18–32 years) and 17 elderly subjects (8 men, 9 women; mean age=71.5 years, SD=5.85, range=65–84 years) participated in this study. Subjects were seated on a dynamometer and stabilized. Central activation was quantified, based on the change in force produced by a 100-Hz, 12-pulse electrical train that was delivered during a 3- to 5-second isometric maximum voluntary contraction (MVC) of the quadriceps femoris muscle. Next, subjects performed 25 MVCs (a 5-second contraction with 2 seconds of rest) to fatigue the muscle. During the last MVC, central activation was measured again. Results. In the nonfatigued state, elderly subjects had lower central activation than younger subjects. In the fatigued state, this difference became larger. Discussion and Conclusion. Central activation of the quadriceps femoris muscle in elderly subjects was reduced in both the fatigued and nonfatigued states when compared with young subjects. Some part of age-related weakness, therefore, may be attributed to failure of central activation in both the fatigued and nonfatigued states.
Propulsive force generation is critical to walking speed. Trialing limb angle and ankle moment are major contributors to increases in propulsive force during gait. For able-bodied individuals, trailing limb angle contributes twice as much as ankle moment to increases in propulsive force during speed modulation. The aim of this study was to quantify the relative contribution of ankle moment and trailing limb angle to increases in propulsive force for individuals poststroke. A biomechanical-based model previously developed for able-bodied individuals was evaluated and enhanced for individuals poststroke. Gait analysis was performed as subjects (N = 24) with chronic poststroke hemiparesis walked at their self-selected and fast walking speeds on a treadmill. Both trailing limb angle and ankle moment increased during speed modulation. In the paretic limb, the contribution from trailing limb angle versus ankle moment to increases in propulsive force is 74% and 17%. In the non-paretic limb, the contribution from trailing limb angle versus ankle moment to increases in propulsive force is 67% and 22%. Individuals poststroke increase propulsive force mainly by changing trailing limb angle in both the paretic and non-paretic limbs. This strategy may contribute to the inefficiency in poststroke walking patterns. Future work is needed to examine whether these characteristics can be modified via intervention.
Background: Foot drop is a common gait impairment after stroke. Functional electrical stimulation (FES) of the ankle dorsiflexor muscles during the swing phase of gait can help correct foot drop. Compared with constant-frequency trains (CFTs), which typically are used during FES, novel stimulation patterns called variable-frequency trains (VFTs) have been shown to enhance isometric and nonisometric muscle performance. However, VFTs have never been used for FES during gait.Objective: The purpose of this study was to compare knee and ankle kinematics during the swing phase of gait when FES was delivered to the ankle dorsiflexor muscles using VFTs versus CFTs.Design: A repeated-measures design was used in this study.Participants: Thirteen individuals with hemiparesis following stroke (9 men, 4 women; age=46–72 years) participated in the study.Methods: Participants completed 20- to 40-second bouts of walking at their self-selected walking speeds. Three walking conditions were compared: walking without FES, walking with dorsiflexor muscle FES using CFTs, and walking with dorsiflexor FES using VFTs.Results: Functional electrical stimulation using both CFTs and VFTs improved ankle dorsiflexion angles during the swing phase of gait compared with walking without FES (X̅±SE=−2.9°±1.2°). Greater ankle dorsiflexion in the swing phase was generated during walking with FES using VFTs (X̅±SE=2.1°±1.5°) versus CFTs (X̅±SE=0.3±1.3°). Surprisingly, dorsiflexor FES resulted in reduced knee flexion during the swing phase and reduced ankle plantar flexion at toe-off.Conclusions: The findings suggest that novel FES systems capable of delivering VFTs during gait can produce enhanced correction of foot drop compared with traditional FES systems that deliver CFTs. The results also suggest that the timing of delivery of FES during gait is critical and merits further investigation.
1 August 2008 in Journal of Electromyography and Kinesiology
During isometric contractions, no true work is performed, so the force-time integral (FTI) is often used to approximate isometric work. However, the relationship between FTI and metabolic cost is not as linear. We tested the hypothesis that this nonlinearity was due to the cost of attaining a given force being greater than that of maintaining it. The ATP consumed per contraction in the human medial gastrocnemius muscle ( n = 6) was determined by use of 31P-NMR spectroscopy during eight different electrical stimulation protocols. Each protocol consisted of 8 trains of a single frequency (20 or 80 Hz) and duration (300, 600, 1,200, or 1,800 ms) performed under ischemic conditions. The cost of force generation was determined from the ATP turnover during the short-duration trains that did not attain a steady force level. Estimates of the cost of force maintenance at each frequency were determined by subtracting the ATP turnover during the shorter-duration trains from the turnover during the long-duration trains. The force generation phase of an isometric contraction was indeed more metabolically costly than the force maintenance phase during both 20- and 80-Hz stimulation. Thus the mean rate of ATP hydrolysis appeared to decline as contraction duration increased. Interestingly, the metabolic costs of maintaining force during 20-Hz and 80-Hz stimulation were comparable, although different levels of force were produced.