Neslihan Colak-Gunes

Dr. Neslihan Colak-Gunes


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2009 in Energy Conversion and Management
Verified
Journal Article
Closed access
NCNeslihan Colak-Gunes
Neslihan Colak-Gunes
AHArif Hepbasli
Arif Hepbasli

1 January 2009 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
AHArif Hepbasli
Arif Hepbasli
Zafer ErbayZafer Erbay
Zafer Erbay
FIFiliz Içier
Filiz Içier
NCNeslihan Colak-Gunes
Neslihan Colak-Gunes
EHEbru Hancioglu
Ebru Hancioglu

1 June 2007 in Journal of Food Engineering
Verified
Journal Article
Closed access
NCNeslihan Colak-Gunes
Neslihan Colak-Gunes
AHArif Hepbasli
Arif Hepbasli

1 September 2009 in Energy Conversion and Management
Verified
Journal Article
Closed access
NCNeslihan Colak-Gunes
Neslihan Colak-Gunes
AHArif Hepbasli
Arif Hepbasli

8 March 2010 in Drying Technology
Verified
Journal Article
Open access
FIFiliz Içier
Filiz Içier
NCNeslihan Colak-Gunes
Neslihan Colak-Gunes
Zafer ErbayZafer Erbay
Zafer Erbay
EKEbru Hancioglu Kuzgunkaya
Ebru Hancioglu Kuzgunkaya
AHArif Hepbasli
Arif Hepbasli
This article deals with the exergy analysis and evaluation of broccoli in three different drying systems. The effects of drying air temperature on the exergy destruction, exergy efficiency, and exergetic improvement potential of the drying process were investigated. The exergy destruction rate for the drying chamber increased with the rise in the drying air temperature at 1.5 m/s, both in the tray and the heat pump dryer. The highest exergy efficiency value was obtained as 90.86% in the fluid bed dryer in comparison to the other two drying systems and the improvement potential rate was the highest in the heat pump dryer during drying of broccoli at the drying air temperature of 45°C and the drying air velocity of 1.0 m/s.

16 March 2005 in International Journal of Energy Research
Verified
Journal Article
Closed access
PDF file
FBFiruz Balkan
Firuz Balkan
NCNeslihan Colak-Gunes
Neslihan Colak-Gunes
AHArif Hepbasli
Arif Hepbasli
The present study evaluates the performance of a triple-effect evaporator with forward feed (TEEFF) system by using exergy analysis based on actual operational data. The orange juice with a capacity of about 1.222 kg s−1 is concentrated from a dry matter (DM) content of 12 to 65% in this TEEFF, which is situated in an orange juice concentrate line installed in a factory, located in Denizli, Turkey. A Visual Basic 6.0 program was also developed to show how the exergetic performance characteristics of the system vary with the feed flow rates ranging from 1.222 to 1.667 kg s−1. The total exergy efficiency of the TEEEFF is found to be on average 0.85. The largest exergy destruction occurs in the first-effect of the TEEFF system with 48.2% of total, followed by the third and second effects with 32.04 and 19.76% of that. Evaporator performance is also rated on the basis of steam economy, which is obtained to be in the range of 2.05–2.14 under the operation conditions. It is expected that the analysis presented here should provide a designer with a better, quantitative grasp of the inefficiencies and their relative magnitudes in the design, simulation and operation of multiple-effect evaporators. Copyright © 2005 John Wiley & Sons, Ltd.