Nils P. Hailer

Prof. Dr. Nils P. Hailer

orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2010 in Acta Orthopaedica
Verified
Journal Article
Open access
NHNils P. Hailer
Nils P. Hailer
GGGöran Garellick
Göran Garellick
JKJohan Kärrholm
Johan Kärrholm
Since the introduction of total hip arthroplasty (THA) in Sweden, both components have most commonly been cemented. A decade ago the frequency of uncemented fixation started to increase, and this change in practice has continued. We therefore analyzed implant survival of cemented and uncemented THA, and whether the modes of failure differ between the two methods of fixation. All patients registered in the Swedish Hip Arthroplasty Register between 1992 and 2007 who received either totally cemented or totally uncemented THA were identified (n = 170,413). Kaplan-Meier survival analysis with revision of any component, and for any reason, as the endpoints was performed. Cox regression models were used to calculate risk ratios (RRs) for revision for various reasons, adjusted for sex, age, and primary diagnosis. Revision-free 10-year survival of uncemented THA was lower than that of cemented THA (85% vs. 94%, p < 0.001). No age or diagnosis groups benefited from the use of uncemented fixation. Cox regression analysis confirmed that uncemented THA had a higher risk of revision for any reason (RR = 1.5, 95% CI: 1.4-1.6) and for aseptic loosening (RR = 1.5, CI: 1.3-1.6). Uncemented cup components had a higher risk of cup revision due to aseptic loosening (RR = 1.8, CI: 1.6-2.0), whereas uncemented stem components had a lower risk of stem revision due to aseptic loosening (RR = 0.4, CI: 0.3-0.5) when compared to cemented components. Uncemented stems were more frequently revised due to periprosthetic fracture during the first 2 postoperative years than cemented stems (RR = 8, CI: 5-14). The 5 most common uncemented cups had no increased risk of revision for any reason when compared with the 5 most commonly used cemented cups (RR = 0.9, CI: 0.6-1.1). There was no significant difference in the risk of revision due to infection between cemented and uncemented THA. Survival of uncemented THA is inferior to that of cemented THA, and this appears to be mainly related to poorer performance of uncemented cups. Uncemented stems perform better than cemented stems; however, unrecognized intraoperative femoral fractures may be an important reason for early failure of uncemented stems. The risk of revision of the most common uncemented cup designs is similar to that of cemented cups, indicating that some of the problems with uncemented cup fixation may have been solved.

3 September 2012 in Acta Orthopaedica
Verified
Journal Article
Open access
NHNils P. Hailer
Nils P. Hailer
RWRüdiger J Weiss
Rüdiger J Weiss
ASAndré Stark
André Stark
JKJohan Kärrholm
Johan Kärrholm
The effects of patient-related and technical factors on the risk of revision due to dislocation after primary total hip arthroplasty (THA) are only partly understood. We hypothesized that increasing the femoral head size can reduce this risk, that the lateral surgical approach is associated with a lower risk than the posterior and minimally invasive approaches, and that gender and diagnosis influence the risk of revision due to dislocation. Data on 78,098 THAs in 61,743 patients performed between 2005 and 2010 were extracted from the Swedish Hip Arthroplasty Register. Inclusion criteria were a head size of 22, 28, 32, or 36 mm, or the use of a dual-mobility cup. The covariates age, sex, primary diagnosis, type of surgical approach, and head size were entered into Cox proportional hazards models in order to calculate the adjusted relative risk (RR) of revision due to dislocation, with 95% confidence intervals (CI). After a mean follow-up of 2.7 (0-6) years, 399 hips (0.5%) had been revised due to dislocation. The use of 22-mm femoral heads resulted in a higher risk of revision than the use of 28-mm heads (RR = 2.0, CI: 1.2-3.3). Only 1 of 287 dual-mobility cups had been revised due to dislocation. Compared with the direct lateral approach, minimally invasive approaches were associated with a higher risk of revision due to dislocation (RR = 4.2, CI: 2.3-7.7), as were posterior approaches (RR = 1.3, CI: 1.1-1.7). An increased risk of revision due to dislocation was found for the diagnoses femoral neck fracture (RR = 3.9, CI: 3.1-5.0) and osteonecrosis of the femoral head (RR = 3.7, CI: 2.5-5.5), whereas women were at lower risk than men (RR = 0.8, CI: 0.7-1.0). Restriction of the analysis to the first 6 months after the index procedure gave similar risk estimates. Patients with femoral neck fracture or osteonecrosis of the femoral head are at higher risk of dislocation. Use of the minimally invasive and posterior approaches also increases this risk, and we raise the question of whether patients belonging to risk groups should be operated using lateral approaches. The use of femoral head diameters above 28 mm or of dual-mobility cups reduced this risk in a clinically relevant manner, but this observation was not statistically significant.


6 December 1996 in Glia
Verified
Journal Article
Closed access
PDF file
NHNils P. Hailer
Nils P. Hailer
JJJosef D. Järhult
Josef D. Järhult
RNRobert Nitsch
Robert Nitsch

5 November 2012 in Acta Orthopaedica
Verified
Journal Article
Open access
NHNils P. Hailer
Nils P. Hailer
RWRüdiger J Weiss
Rüdiger J Weiss
ASAndré Stark
André Stark
JKJohan Kärrholm
Johan Kärrholm
Revision total hip arthroplasty (THA) due to recurrent dislocations is associated with a high risk of persistent instability. We hypothesized that the use of dual-mobility cups would reduce the risk of re-revision due to dislocation after revision THA. 228 THA cup revisions (in 228 patients) performed due to recurrent dislocations and employing a specific dual-mobility cup (Avantage) were identified in the Swedish Hip Arthroplasty Register. Kaplan-Meier survival analysis was performed with re-revision due to dislocation as the primary endpoint and re-revision for any reason as the secondary endpoint. Cox regression models were fitted in order to calculate the influence of various covariates on the risk of re-revision. 58 patients (25%) had been revised at least once prior to the index cup revision. The surgical approach at the index cup revision was lateral in 99 cases (44%) and posterior in 124 cases (56%). Median follow-up was 2 (0-6) years after the index cup revision, and by then 18 patients (8%) had been re-revised for any reason. Of these, 4 patients (2%) had been re-revised due to dislocation. Survival after 2 years with the endpoint revision of any component due to dislocation was 99% (95% CI: 97-100), and it was 93% (CI: 90-97) with the endpoint revision of any component for any reason. Risk factors for subsequent re-revision for any reason were age between 50-59 years at the time of the index cup revision (risk ratio (RR) = 5 when compared with age > 75, CI: 1-23) and previous revision surgery to the relevant joint (RR = 1.7 per previous revision, CI: 1-3). The risk of re-revision due to dislocation after insertion of dual-mobility cups during revision THA performed for recurrent dislocations appears to be low in the short term. Since most dislocations occur early after revision THA, we believe that this device adequately addresses the problem of recurrent instability. Younger age and prior hip revision surgery are risk factors for further revision surgery. However, problems such as potentially increased liner wear and subsequent aseptic loosening may be associated with the use of such devices in the long term.

1 September 1999 in European Journal of Neuroscience
Verified
Journal Article
Closed access
PDF file
NHNils P. Hailer
Nils P. Hailer
AGAnne Grampp
Anne Grampp
RNRobert Nitsch
Robert Nitsch