Błażej Torzyk

Mr. Błażej Torzyk

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
BTBłażej Torzyk
Błażej Torzyk
BWBoguslaw Wiecek
Boguslaw Wiecek
This paper presents a new method for measuring RMS values of AC (Alternative Current) in power lines using an infrared camera. An IR camera registers thermal images in time with an appropriate frame rate in order to calculate the spectrum of the temperature signal of a power cable. For the European standard, the amplitudes of the harmonics for f ≈ 100 Hz correlate to the power dissipated in a conductor. The FFT and RMS analysis for different current values were performed. The obtained results allow plotting the calibration curve of temperature changes versus the RMS values of the current flowing in wire. They confirmed the linear relation between the 100 (Hz) spectral component of the temperature and the square value of the RMS current. This method has unique advantages. It is non-contact and makes it possible to estimate the RMS current regardless of the ambient background radiation and convection cooling conditions having a significant impact on overhead lines, in particular.

24 February 2024 in Sensors
Verified
Journal Article
Open access
PDF file
MSMaria Strąkowska
Maria Strąkowska
SUSebastian Urbaś
Sebastian Urbaś
MFMariusz Felczak
Mariusz Felczak
BTBłażej Torzyk
Błażej Torzyk
ISIyad S. M. Shatarah
Iyad S. M. Shatarah
BWBogusław Więcek
Bogusław Więcek
This paper presents a simple engineering method for evaluating the optical power emitted by light-emitting diodes (LEDs) using infrared thermography. The method is based on the simultaneous measurement of the electrical power and temperature of an LED and a heat source (resistor) that are enclosed in the same plastic packaging under the same cooling conditions. This ensures the calculation of the optical power emitted by the LED regardless of the value of the heat transfer coefficient. The obtained result was confirmed by comparing it with the standard direct measurement method using an integrated sphere. The values of the estimated optical power using the proposed method and the integrated sphere equipped with a spectrometer were consistent with each other. The tested LED exhibited a high optical energy efficiency, reaching approximately η ≈ 30%. In addition, an uncertainty analysis of the obtained results was performed. Compact modelling based on a thermal resistor network (Rth) and a 3D-FEM analysis were performed to confirm the experimental results.

7 December 2021 in Pomiary Automatyka Robotyka
Verified
Journal Article
Closed access
BTBłażej Torzyk
Błażej Torzyk
BWBogusław Więcek
Bogusław Więcek
The article presents the concept of using VNA (Vector Network Analyzer) to measure the temperature of the MOS transistor junction. The method assumes that the scattering parameters of the network consisting of the transistor depend on the temperature. The tests confirmed the influence of temperature on the S11 parameter and the input network capacity during ambient temperature changes in the range of 35–70 °C. Measurements were made for the gate-source (G-S) input of the system. The measurements were carried-out with the transistor in the ON/OFF states. In order to validate the measurements, the temperature of the tested element was recorded with the MWIR Cedip-Titanium thermal imaging camera.

18 September 2024 in Pomiary Automatyka Robotyka
Verified
Journal Article
Closed access
BTBłażej Torzyk
Błażej Torzyk
BWBogusław Więcek
Bogusław Więcek
This paper presents a new method of the effective value (RMS) of alternating current (AC) in power wires based on infrared radiation (IR) measurement using a high-speed medium wavelength infrared (MWIR) camera. The method called “2-ω” involves measurement of the 100 Hz harmonic of temperature (T100) and is supported by signal analysis in the frequency domain. The article discusses the issue of non-sinusoidal alternating current, which causes much more difficult analyzes compared to sinusoidal current with a frequency of 50/60 Hz. The simulation and measurement results for different current shapes obtained in typical power systems like: a phase-controlled switching regulator, half-wave and full-wave rectifiers, and finally the nonlinear distortion of the AC current due to saturation of the magnetic core, are presented and confirm the linear relation of T100 ~ I2RMS. The main advantage of proposed method is the independence of the measurement results from environmental conditions.

20 December 2023 in Pomiary Automatyka Robotyka
Verified
Journal Article
Closed access
PŁPolitechnika Łódzka
Politechnika Łódzka
BTBłażej Torzyk
Błażej Torzyk
BWBogusław Więcek
Bogusław Więcek
NETD (Noise Equivalent Temperature Difference) parameter of infrared systems is the important parameter that allows determining the limit of temperature measurement of tested objects. Currently, the commercially available devices have the NETD < 20 mK. The infrared (IR) detectors and accompanying electronic circuits generate noise. In consequence, it is difficult to achieve the high level of signal-to-noise ratio (SNR) while measuring temperature. This paper presents a method of measuring the root mean square (RMS) value of alternating current, using a single-detector high-speed IR system for detecting 100 Hz harmonic spectral component of temperature, whose value is certainly below NETD limit.