The recent introduction of novel treatments for advanced neuroendocrine tumors (NETs) and the well-established impact of clinical case discussion within dedicated multidisciplinary teams indicates the need to promote the centralization of rare diseases, such as NENs (neuroendocrine neoplasms). Data on the real-life use of and indications for [68Ga]Ga-DOTANOC PET/CT were collected from a prospective monocentric 5-year electronic archive including consecutive patients with confirmed and suspected NETs (September 2017 to May 2022). Overall, 2082 [68Ga]Ga-DOTANOC PET/CT scans (1685 confirmed NETs, 397 suspected NETs) were performed in 1537 patients. A high positivity rate was observed across different clinical settings (approximately 70%). Approximately 910/2082 scans were requested by the local oncology ward (851 confirmed NETs, 59 suspected NETs). The following observations were found: (i) the detection rate across all indications was 73.2% (higher for staging, peptide receptor radioligand therapy (PRRT) selection, and treatment response assessment); (ii) in suspected NETs, PET was more often positive when based on radiological findings. This systematic data collection in a high-volume diagnostic center represents a reliable cohort reflecting the global trends in the use of [68Ga]Ga-DOTANOC PET/CT for different clinical indications and primary tumor sites, but prompts the need for further multicenter data sharing in such a rare and slowly progressive disease setting.
Background: Image reconstruction is crucial for improving overall image quality and diagnostic accuracy. Q.Clear is a novel reconstruction algorithm that reduces image noise. The aim of the present study is to assess the preferred Q.Clear β-level for digital [68Ga]Ga-DOTANOC PET/CT reconstruction vs. standard reconstruction (STD) for both overall scan and single-lesion visualization. Methods: Inclusion criteria: (1) patients with/suspected neuroendocrine tumors included in a prospective observational monocentric study between September 2019 and January 2022; (2) [68Ga]Ga-DOTANOC digital PET/CT and contrast-enhanced-CT (ceCT) performed at our center at the same time. Images were reconstructed with STD and with Q.Clear β-levels 800, 1000, and 1600. Scans were blindly reviewed by three nuclear-medicine experts: the preferred β-level reconstruction was independently chosen for the visual quality of both the overall scan and the most avid target lesion < 1 cm (t) and >1 cm (T). PET/CT results were compared to ceCT. Semiquantitative analysis was performed (STD vs. β1600) in T and t concordant at both PET/CT and ceCT. Subgroup analysis was also performed in patients presenting discordant t. Results: Overall, 52 patients were included. β1600 reconstruction was considered superior over the others for both overall scan quality and single-lesion detection in all cases. The only significantly different (p < 0.001) parameters between β1600 and STD were signal-to-noise liver ratio and standard deviation of the liver background. Lesion-dependent parameters were not significantly different in concordant T (n = 37) and t (n = 10). Among 26 discordant t, when PET was positive, all findings were confirmed as malignant. Conclusions: β1600 Q.Clear reconstruction for [68Ga]Ga-DOTANOC imaging is feasible and improves image quality for both overall and small-lesion assessment.