Patrick Poulin

Mr. Patrick Poulin


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
MLMarie-Eve Levasseur
Marie-Eve Levasseur
PPPatrick Poulin
Patrick Poulin
CCCeline Campagna
Celine Campagna
JLJean-Marc Leclerc
Jean-Marc Leclerc
A paradigm change in the management of environmental health issues has been observed in recent years: instead of managing specific risks individually, a holistic vision of environmental problems would assure sustainable solutions. However, concrete actions that could help translate these recommendations into interventions are lacking. This review presents the relevance of using an integrated indoor air quality management approach to ensure occupant health and comfort. At the nexus of three basic concepts (reducing contaminants at the source, improving ventilation, and, when relevant, purifying the indoor air), this approach can help maintain and improve indoor air quality and limit exposure to several contaminants. Its application is particularly relevant in a climate change context since the evolving outdoor conditions have to be taken into account during building construction and renovation. The measures presented through this approach target public health players, building managers, owners, occupants, and professionals involved in building design, construction, renovation, and maintenance. The findings of this review will help the various stakeholders initiate a strategic reflection on the importance of indoor air quality and climate change issues for existing and future buildings. Several new avenues and recommendations are presented to set the path for future research activities.

23 February 2022 in Indoor Air
Verified
Journal Article
Closed access
PDF file
PPPatrick Poulin
Patrick Poulin
AMAxelle Marchand
Axelle Marchand
BLBenoît Lévesque
Benoît Lévesque
MDMarjolaine Dubé
Marjolaine Dubé
DADaniel Aubin
Daniel Aubin
MBMario Brisson
Mario Brisson

24 January 2012 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
PPPatrick Poulin
Patrick Poulin
JLJean-Marc Leclerc
Jean-Marc Leclerc
JDJean-Claude Dessau
Jean-Claude Dessau
WDWilber Deck
Wilber Deck
FGFabien Gagnon
Fabien Gagnon
The purpose of this study was to measure radon concentration in public primary schools located in priority investigation areas, with the aim of decreasing occupants' exposure to radon in public buildings where concentrations exceed the Canadian Federal guidelines (i.e. 200 Bq m–3). In addition, the association between radon levels, substratum geological characteristics and schools' structural characteristics were investigated. The results showed that radon concentrations measured in the 65 investigated schools are generally below the Federal guideline levels. Eleven schools (17 %) had at least one measurement above the Federal guideline, while one had a level above 600 Bq m−3. On average, targeted schools' occupants are exposed to radon concentrations of 56 Bq m−3. Although statistical analysis, which was limited by the sample size, did not show any link between aggregated radon measurements and geochemical or radiological signatures of investigated sites, the geological evidence that led to the choice of the studied regions remains relevant.