Yangxin Zhang

Dr. Yangxin Zhang

orcid

Research Focus & Metrics

Representative Publications

View All Publications
19 February 2024 in Water
Verified
Journal Article
Open access
PDF file
YZYangxin Zhang
Yangxin Zhang
JZJiangmei Zhang
Jiangmei Zhang
TLTuantuan Liu
Tuantuan Liu
XFXinghua Feng
Xinghua Feng
TXTengxiang Xie
Tengxiang Xie
HLHaolin Liu
Haolin Liu
Many nuclear power plants have been built along China’s coasts, and the migration and diffusion of radioactive nuclides in coastal harbours is very concerning. In this study, considering the decay and free diffusion of radioactive nuclides, a local hydrodynamic model based on the FVCOM was built to investigate the migration and diffusion of the radioactive nuclide tritium in Haizhou Bay, China. This model was calibrated according to the observed tidal level and flow velocity and direction, which provide an accurate background. This study aimed to evaluate the impact of tides and monsoons on the migration path and concentration variations in tritium over time. The results demonstrated that the simulated flow field can reflect real-life receiving waters. The distribution of the tritium concentration is affected by the flow field, which is related to the tides. Moreover, more severe radioactive contamination was exhibited in winter than in summer because monsoons may have hindered the migration and diffusion of tritium within the harbour. Given the poor hydrodynamic conditions and slow water exchange in the open ocean in Haizhou Bay, the diffusion rate of radioactive nuclides outside the bay area was higher than that within it.

28 October 2025 in Water
Verified
Journal Article
Open access
PDF file
YZYangxin Zhang
Yangxin Zhang
JZJiangmei Zhang
Jiangmei Zhang
XFXinghua Feng
Xinghua Feng
HLHaolin Liu
Haolin Liu
GYGuowei Yang
Guowei Yang
JLJiaze Li
Jiaze Li
The parameter optimization of marine hydrodynamic models currently relies predominantly on expert empirical knowledge, but the quantitative indicators and weighting mechanisms for rapid calibration remain unclear due to inherent model uncertainties and complexities. This study addresses these challenges through expert questionnaires that collect fuzzy evaluations of calibration criteria, developing an integrated methodology combining the theory of axiomatic fuzzy set (AFS) with principal component analysis (PCA). Numerical case studies quantify calibration indicator weights and assess critical parameter impacts, revealing that bathymetry and roughness coefficients predominantly govern simulation accuracy. Elevated roughness conditions demonstrate two regimes: (1) at 1–2 × baseline roughness, strong positive correlations (with a coefficient of determination R2 increased by up to 0.568 compared to baseline) confirm effective model-data matching for tidal levels/currents; (2) beyond 2 × baseline roughness, progressive correlation decay accompanies increasing coefficients, indicating amplified simulation–measurement discrepancies. Notably, under reduced roughness conditions, high accuracy persists during spring/mid-tide phases but significantly diminishes during neap tides, demonstrating enhanced roughness sensitivity in low-tidal energy regimes.

11 June 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
YLYongzhuo LIU
Yongzhuo LIU
JZJiangmei Zhang
Jiangmei Zhang
FXFayuan Xi
Fayuan Xi
JLJing Lu
Jing Lu
HLHaolin Liu
Haolin Liu
YZYangxin Zhang
Yangxin Zhang
Rapid screening of mixed nuclear technical waste requires a radiation measurement layer that can provide both conservative risk estimation and region-level spatial information. This study proposes an OpenGATE/Geant4-based gamma response mapping framework for a 10 × 10 planar multi-range Geiger–Mueller detector array with a lead-grid coarse collimation structure. The simulated photon-transport response is converted into a simulation-normalized dose-rate score map through a statistical multi-range GM fusion model considering dead-time correction, valid-range weighting, and counting uncertainty. The framework was evaluated using particle-number convergence, lead-grid parameter analysis, measurement-time assessment, source-depth and shielding robustness tests, known-level screening validation, independent randomized validation, and robotic sorting priority experiments. The lead grid reduced the neighbor-8/peak crosstalk ratio from 1.905 without lead to 1.075 for the 10 mm/40 mm configuration, with a 57.4% reduction in total counts. A 5 s acquisition achieved a repeated-postprocessing coefficient of variation of approximately 1.85%. The independent randomized validation achieved 96.0% accuracy with no dangerous underestimation. In 50 randomized waste-bag scenarios, the first selected item was an L3 or L4 source in 49/50 cases, with an average top-3 high-risk recall of 0.940. The reported values are simulation-normalized screening scores rather than calibrated ambient dose-equivalent rates; standard-source calibration and prototype validation are required before absolute dose-rate interpretation.