Tim Bui

Mr. Tim Bui

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2024 in Medicina
Verified
Journal Article
Open access
PDF file
TBTim Bui
Tim Bui
MRMiguel A Ruiz-Cardozo
Miguel A Ruiz-Cardozo
HDHarsh S. Dave
Harsh S. Dave
KBKarma Barot
Karma Barot
MKMichael Ryan Kann
Michael Ryan Kann
CMCamilo A. Molina
Camilo A. Molina
Background and Objectives: Advances in virtual reality (VR), augmented reality (AR), and mixed reality (MR) technologies have resulted in their increased application across many medical specialties. VR’s main application has been for teaching and preparatory roles, while AR has been mostly used as a surgical adjunct. The objective of this study is to discuss the various applications and prospects for VR, AR, and MR specifically as they relate to spine surgery. Materials and Methods: A systematic review was conducted to examine the current applications of VR, AR, and MR with a focus on spine surgery. A literature search of two electronic databases (PubMed and Scopus) was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). The study quality was assessed using the MERSQI score for educational research studies, QUACS for cadaveric studies, and the JBI critical appraisal tools for clinical studies. Results: A total of 228 articles were identified in the primary literature review. Following title/abstract screening and full-text review, 46 articles were included in the review. These articles comprised nine studies performed in artificial models, nine cadaveric studies, four clinical case studies, nineteen clinical case series, one clinical case–control study, and four clinical parallel control studies. Teaching applications utilizing holographic overlays are the most intensively studied aspect of AR/VR; the most simulated surgical procedure is pedicle screw placement. Conclusions: VR provides a reproducible and robust medium for surgical training through surgical simulations and for patient education through various platforms. Existing AR/MR platforms enhance the accuracy and precision of spine surgeries and show promise as a surgical adjunct.

1 January 2014 in The Bone & Joint Journal
Verified
Journal Article
Closed access
FSF. Shapiro
F. Shapiro
DZDavid Zurakowski
David Zurakowski
TBTim Bui
Tim Bui
BDB. T. Darras
B. T. Darras
We determined the frequency, rate and extent of development of scoliosis (coronal plane deformity) in wheelchair-dependent patients with Duchenne muscular dystrophy (DMD) who were not receiving steroid treatment. We also assessed kyphosis and lordosis (sagittal plane deformity). The extent of scoliosis was assessed on sitting anteroposterior (AP) spinal radiographs in 88 consecutive non-ambulatory patients with DMD. Radiographs were studied from the time the patients became wheelchair-dependent until the time of spinal fusion, or the latest assessment if surgery was not undertaken. Progression was estimated using a longitudinal mixed-model regression analysis to handle repeated measurements. Scoliosis ≥ 10° occurred in 85 of 88 patients (97%), ≥ 20° in 78 of 88 (89%) and ≥ 30° in 66 of 88 patients (75%). The fitted longitudinal model revealed that time in a wheelchair was a highly significant predictor of the magnitude of the curve, independent of the age of the patient (p < 0.001). Scoliosis developed in virtually all DMD patients not receiving steroids once they became wheelchair-dependent, and the degree of deformity deteriorated over time. In general, scoliosis increased at a constant rate, beginning at the time of wheelchair-dependency (p < 0.001). In some there was no scoliosis for as long as three years after dependency, but scoliosis then developed and increased at a constant rate. Some patients showed a rapid increase in the rate of progression of the curve after a few years – the clinical phenomenon of a rapidly collapsing curve over a few months. A sagittal plane kyphotic deformity was seen in 37 of 60 patients (62%) with appropriate radiographs, with 23 (38%) showing lumbar lordosis (16 (27%) abnormal and seven (11%) normal). This study provides a baseline to assess the effects of steroids and other forms of treatment on the natural history of scoliosis in patients with DMD, and an approach to assessing spinal deformity in the coronal and sagittal planes in wheelchair-dependent patients with other neuromuscular disorders. Cite this article: Bone Joint J 2014;96-B:100–5.

23 August 2024 in The Spine Journal
Verified
Journal Article
Open access
MRMiguel A Ruiz-Cardozo
Miguel A Ruiz-Cardozo
KBKarma Barot
Karma Barot
SBSamuel Brehm
Samuel Brehm
TBTim Bui
Tim Bui
KJKaran Joseph Karan Joseph
Karan Joseph Karan Joseph
CMCamilo A. Molina
Camilo A. Molina
The accurate and safe positioning of cervical pedicle screws is crucial. While augmented reality (AR) use in spine surgery has previously demonstrated clinical utility in the thoracolumbar spine, its technical feasibility in the cervical spine remains less explored. The objective of this study was to assess the precision and safety of AR-assisted pedicle screw placement in the cervical spine. In this experimental study, five cadaveric cervical spine models were instrumented from C3 to C7 by five different spine surgeons. The navigation accuracy and clinical screw accuracy were evaluated. Post-procedural CT scans were evaluated for clinical accuracy by two independent neuroradiologists using the Gertzbein-Robbins scale. Technical precision was assessed by calculating the angular trajectory (°) and linear screw tip (mm) deviations in the axial and sagittal planes from the virtual pedicle screw position as recorded by the AR-guided platform during the procedure compared to the actual pedicle screw position derived from post-procedural imaging. A total of forty-one pedicle screws were placed in five cervical cadavers, with each of the five surgeons navigating at least seven screws. Gertzbein-Robbins grade of A or B was achieved in 100% of cases. The mean values for tip and trajectory errors in the axial and sagittal planes between the virtual versus actual position of the screws was less than 3 mm and 30°, respectively (p<0.05). None of the cervical screws violated the cortex by more than 2 mm or displaced neurovascular structures. AR-assisted cervical pedicle screw placement in cadavers demonstrated clinical accuracy comparable to existing literature values for image-guided navigation methods for the cervical spine. This study provides technical and clinical accuracy data that supports clinical trialing of AR-assisted subaxial cervical pedicle screw placement.

6 February 2024 in Medicina
Verified
Journal Article
Open access
PDF file
MKMichael Ryan Kann
Michael Ryan Kann
MRMiguel A Ruiz-Cardozo
Miguel A Ruiz-Cardozo
SBSamuel Brehm
Samuel Brehm
TBTim Bui
Tim Bui
KJKaran Joseph Karan Joseph
Karan Joseph Karan Joseph
CMCamilo A. Molina
Camilo A. Molina
Background and Objectives: Augmented reality head-mounted display (AR-HMD) is a novel technology that provides surgeons with a real-time CT-guided 3-dimensional recapitulation of a patient’s spinal anatomy. In this case series, we explore the use of AR-HMD alongside more traditional robotic assistance in surgical spine trauma cases to determine their effect on operative costs and perioperative outcomes. Materials and Methods: We retrospectively reviewed trauma patients who underwent pedicle screw placement surgery guided by AR-HMD or robotic-assisted platforms at an academic tertiary care center between 1 January 2021 and 31 December 2022. Outcome distributions were compared using the Mann–Whitney U test. Results: The AR cohort (n = 9) had a mean age of 66 years, BMI of 29.4 kg/m2, Charlson Comorbidity Index (CCI) of 4.1, and Surgical Invasiveness Index (SII) of 8.8. In total, 77 pedicle screws were placed in this cohort. Intra-operatively, there was a mean blood loss of 378 mL, 0.78 units transfused, 398 min spent in the operating room, and a 20-day LOS. The robotic cohort (n = 13) had a mean age of 56 years, BMI of 27.1 kg/m2, CCI of 3.8, and SII of 14.2. In total, 128 pedicle screws were placed in this cohort. Intra-operatively, there was a mean blood loss of 432 mL, 0.46 units transfused units used, 331 min spent in the operating room, and a 10.4-day LOS. No significant difference was found between the two cohorts in any outcome metrics. Conclusions: Although the need to address urgent spinal conditions poses a significant challenge to the implementation of innovative technologies in spine surgery, this study represents an initial effort to show that AR-HMD can yield comparable outcomes to traditional robotic surgical techniques. Moreover, it highlights the potential for AR-HMD to be readily integrated into Level 1 trauma centers without requiring extensive modifications or adjustments.

31 July 2025 in Spine
Verified
Journal Article
Closed access
TBTim Bui
Tim Bui
KJKaran Bs Joseph
Karan Bs Joseph
AYAlexander T. Yahanda
Alexander T. Yahanda
SVSamuel Ba Vogl
Samuel Ba Vogl
JGJt Bs Galla
Jt Bs Galla
CMCamilo A. Molina
Camilo A. Molina
Study Design.: Retrospective cohort. Objective.: To evaluate the relationship between the lower lordotic arch (LLA) and other parameters of spinopelvic alignment in adult spinal deformity (ASD). Summary of Background Data.: Lordotic and kyphotic curves maintain a geometrically balanced relationship defined by inflection points and apices along the spine. One proposed relationship suggests that pelvic positioning should be intimately related to the LLA, defined as the Cobb angle between the lordotic apex and L5. Methods.: We reviewed data of 304 adult thoracolumbar fusion patients between 2014 and 2024. KEOPS software was used to segment the sagittal spine and calculate relevant Cobb angles from preoperative and six-week postoperative scoliosis radiographs. Results.: Sacral slope (SS) and LLA lordosis were correlated among preoperative (ρ=0.64, P <0.001) and postoperative (ρ=0.64, P <0.001) measurements. Linear regression of changes in SS versus change in lordosis of LLA from surgery was significant (y=0.77x+3.6, R =0.47, P <0.001). Extending the caudal measurement of LLA to S1 (LLA-S1) increased strength of correlation preoperative (ρ=0.73, P <0.001) and postoperatively (ρ=0.86, P <0.001). Change in SS versus change in LLA-S1 lordosis was also more precise (R=0.62) than using LLA. Inflection point (IP) position was correlated to LLA lordosis preoperatively and postoperatively. Rostral migration of the IP was significantly associated with additional lordosis in the LLA after surgery (ρ=0.22, P <0.001). Conclusions.: SS measurements were correlated with LLA before and after surgery. This relationship was consistent when observing changes in SS versus changes in the LLA induced by deformity correction, and these relationships were further strengthened when comparing SS to LLA-S1 instead of LLA. LLA was also found to rostrally migrate the IP position. Increasing lordosis in the LLA is a major driver of increasing SS without affecting PI—and by extension decreasing pelvic tilt—in ASD correction.

4 August 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
TBTim Bui
Tim Bui
KJKaran Joseph Karan Joseph
Karan Joseph Karan Joseph
AYAlexander Thomas Yahanda
Alexander Thomas Yahanda
SVSamuel Vogl
Samuel Vogl
MRMiguel A Ruiz-Cardozo
Miguel A Ruiz-Cardozo
CMCamilo A. Molina
Camilo A. Molina
Background/Objectives: We sought to characterize the variance and overlap among definitions of Proximal Junctional Kyphosis (PJK) used in the adult spinal deformity (ASD) literature. PJK is defined as excess in PJK angle, a Cobb angle between the upper-instrumented vertebra (UIV) and a supra-adjacent vertebra (SAV), either one (UIV+1) or two (UIV+2) levels rostral of the UIV. No expert consensus exists for threshold angle or which SAV to use. Methods: A total of 116 thoracolumbar fusion patients ≥ 65 years old were reviewed. The UIV+1 and UIV+2 angles were measured. Six definitions of PJK from the literature were evaluated. These definitions were selected based on citation frequency, historical relevance, and accessibility through commonly used databases. Pearson’s Chi-squared and pairwise comparisons were performed to evaluate the distinctness and agreement rates among these definitions. Results: The six definitions of PJK were as follows: [PJK20] PJK angle ≥ 20° with UIV+2 as the (SAV), [PJK10] PJK angle ≥ 10° with a >10° change from pre-op with UIV+2 as the SAV, [PJK2SD] PJK angle > 2 standard deviations from average with UIV+1 as the SAV, [PJK10+10] PJK angle ≥ 10° with a >10° change from pre-op with UIV+1 as the SAV, [PJK15] PJK angle > 15° with UIV+1 as the SAV, and [PJK30] PJK angle > 30° with UIV+2 as the SAV, or displaced rod fracture, or reoperation within 2 years for junctional failure, pseudoarthrosis, or rod fracture. [PJK10] and [PJK2SD] were the most distinct definitions while [PJK20], [PJK10+10], [PJK15], and [PJK30] showed no significant pairwise differences. [PJK2SD] was stringent, while definition [PJK30] included unique diagnostic information not captured by other definitions. Conclusions: The use of [PJK20], [PJK10+10], [PJK15], or [PJK30] is recommended for consistency, with [PJK15] presenting the best balance. Stringent [PJK2SD] may be beneficial for identifying severe PJK, though with low sensitivity. Overall, PJK definitions must be standardized for the consistent reporting of clinical outcomes and research comparability.