Remote detection of alpha emitters is achieved by measuring the secondary radioluminescence light (air fluorescence) that is induced by alpha particles when absorbed in air. A telescope was used to collect the radioluminescence photons to a photomultiplier tube, which is operated in the photon counting mode. Careful matching of photocathode response and filter pass-band allows the sensing of a faint radioluminescence emission in a brightly illuminated environment, which is essential for operative use. A minimum detectable alpha activity of 4 kBq was reached at 1 m distance in 10 s time, when ultraviolet-free lighting is present, and 800 kBq under bright fluorescent lighting. These sensitivities are realized using an ultra-bialkali and cesium-telluride photocathodes in the aforementioned environments respectively. The presented approach is a robust and affordable solution to remotely detect and localize moderate alpha activities in a field environment, providing a means for automated alpha contamination mapping. Moreover, it is shown that a signal increase of more than two orders of magnitude (150–420) can be achieved in deep ultraviolet (close to 260 nm), if nitrogen or argon purge are used to enhance the detection.
9 December 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
A novel multipass photoacoustic cell with five stacked electromechanical films as a microphone has been constructed, tested and characterized. The photoacoustic cell is an open rectangular structure with two steel plates facing each other. The longitudinal acoustic resonances are excited transversely in an optical multipass configuration. A detection limit of 22 ppb (10−9) was achieved for flowing NO2 in N2 at normal pressure by using the maximum of 70 laser beams between the resonator plates. The corresponding minimum detectable absorption and the normalized noise-equivalent absorption coefficients were 2:2 × 10−7 cm−1 and 3:2 × 10−9 cm−1WHz−1/2, respectively.
17 January 2013 in IEEE Transactions on Nuclear Science
A fluorescence-based alpha-gamma coincidence spectrometry approach has been developed for the analysis of alpha-emitting radionuclides. The thermalization of alpha particles in air produces UV light, which in turn can be detected over long distances. The simultaneous detection of UV and gamma photons allows detailed gamma analyses of a single spot of interest even in highly active surroundings. Alpha particles can also be detected indirectly from samples inside sealed plastic bags, which minimizes the risk of cross-contamination. The position-sensitive alpha-UV-gamma coincidence technique reveals the presence of alpha emitters and identifies the nuclides ten times faster than conventional gamma spectrometry.