Elena Martínez-Plaza

Dr. Elena Martínez-Plaza

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
EMElena Martínez-Plaza
Elena Martínez-Plaza
AMAlberto López Miguel
Alberto López Miguel
ARAlberto López-De la Rosa
Alberto López-De la Rosa
Colm McAlindenColm McAlinden
Colm McAlinden
IMItziar Fernández Martínez
Itziar Fernández Martínez
MMMiguel J. Maldonado
Miguel J. Maldonado

1 November 2019 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
EMElena Martínez-Plaza
Elena Martínez-Plaza
AMAlberto López Miguel
Alberto López Miguel
IMItziar Fernández Martínez
Itziar Fernández Martínez
FBFrancisco Blázquez-Arauzo
Francisco Blázquez-Arauzo
MMMiguel J. Maldonado
Miguel J. Maldonado
To analyze the effect of the central hole location in the V4c implantable collamer lens (ICL) on the quality of vision, including progressive headlight glare simulation and quality of life. IOBA-Eye Institute, Valladolid, Spain. Case series. The central hole location was determined by slitlamp and dual Scheimpflug imaging for 6 months or more postoperatively. The visual acuity, mesopic contrast sensitivity, halogen glare contrast sensitivity, xenon glare contrast sensitivity, photostress recovery time after glare, de Boer scale, and Quality of Life Impact of Refractive Correction (QIRC) questionnaire results were evaluated. Multiple regression models were used to analyze the effect of the central hole location on parameters using the pupil center and visual axis as references based on Cartesian and polar coordinates. The safety index was 1.13 and the efficacy index, 1.12. Under all testing circumstances, central hole decentration did not affect the visual acuity or contrast sensitivity. With the visual axis as a reference, worse QIRC values were associated with greater upward central hole displacement (P = .03) and a lower polar angle value (P = .008); also, halogen glare discomfort was greater with a higher radius (P = .04). Using the pupil center as a reference, greater nasal central hole decentration was associated with longer xenon glare photostress recovery time (P = .002). Implantation of the ICL with a central hole yielded excellent visual outcomes, even under increasing glare sources, regardless of the hole's location. However, hole decentration might affect patient-perceived quality of life, bothersome halogen glare, and longer xenon glare photostress recovery time. Such complaints after the early postoperative period might be managed with discrete ICL centration if the central hole is decentered upward or nasally.

1 February 2023 in Expert Review of Medical Devices
Verified
Journal Article
Closed access
EMElena Martínez-Plaza
Elena Martínez-Plaza
ARAlberto López-De la Rosa
Alberto López-De la Rosa
AMAlberto López Miguel
Alberto López Miguel
AHAlfredo Holgueras
Alfredo Holgueras
MMMiguel J. Maldonado
Miguel J. Maldonado
Intraocular lens implantation in phakic eyes for the correction of refractive error is currently a widespread procedure. The EVO and EVO+ Visian Implantable Collamer Lenses (ICL) are two of the mos...

19 May 2023 in Vision
Verified
Journal Article
Open access
PDF file
AMAinhoa Molina-Martín
Ainhoa Molina-Martín
Luis Leal VegaLuis Leal Vega
Luis Leal Vega
DFDolores de Fez
Dolores de Fez
EMElena Martínez-Plaza
Elena Martínez-Plaza
MMMaría Begoña Coco Martín
María Begoña Coco Martín
David P PiñeroDavid P Piñero
David P Piñero
The use of digital devices provides a wide range of possibilities for measuring and improving visual function, including concepts such as perceptual learning and dichoptic therapy. Different technologies can be used to apply these concepts, including, in recent years, the introduction of virtual reality (VR) systems. A preliminary experience in treating anisometropic amblyopia through an immersive VR device and using prototype software is described. A total of 4 children were treated by performing 18 office-based sessions. Results showed that distance VA in amblyopic eyes remained constant in two subjects, whereas the younger subjects improved after the training. Near VA improved in three subjects. All subjects showed an increase in the stereopsis of at least one step, with three subjects showing a final stereopsis of a 60 s arc. A total of three subjects showed an increase of approximately 0.5 CS units for the spatial frequency of 3 cpd after the training. Results from this pilot study suggest that visual training based on perceptual learning through an immersive VR environment could be a viable treatment for improving CS, VA, and stereopsis in some children with anisometropic amblyopia. Future studies should support these preliminary results.

17 April 2025 in American Journal of Ophthalmology
Verified
Journal Article
Open access
AHAmanda Vázquez Hernández
Amanda Vázquez Hernández
MBMarta Blanco-Vázquez
Marta Blanco-Vázquez
EMElena Martínez-Plaza
Elena Martínez-Plaza
ESEva M. Sobas
Eva M. Sobas
MGMaría J. González-García
María J. González-García
MCMargarita Calonge
Margarita Calonge
Chronic neuropathic ocular pain (NOP) can develop alongside chronic dry eye (DE) post-laser-assisted in-situ keratomileusis (LASIK), yet its specific characteristics remain poorly understood. This study aims to compare the clinical characteristics of patients who developed both DE and NOP after LASIK to those with only DE and to asymptomatic LASIK patients, to facilitate the diagnosis of NOP. Prospective, cross-sectional "case-control" comparison study. An 89-subject post-LASIK study comprised 3 groups: 34 patients developing NOP and DE (NOP-DE group), 25 patients developing only DE (DE group), and 30 asymptomatic subjects (control group). Assessments included clinical history and symptom questionnaires (OSDI, mSIDEQ, NRS, WFPRS), anxiety and depression evaluation (HADS), tear film stability (osmolarity and TBUT) and production (Schirmer), and ocular surface integrity. Corneal mechanical and thermal sensitivity thresholds were measured using Belmonte's noncontact esthesiometer, whereas tactile sensitivity threshold was assessed pre-/post-topical anesthesia using the Cochet-Bonnet esthesiometer. In vivo confocal microscopy (IVCM) was used to evaluate the sub-basal nerve plexus characteristics and dendritic cell density in the central cornea. Group comparisons and correlations were conducted. Compared with DE group, patients in the NOP-DE group exhibited significantly more DE symptoms with mSIDEQ (P = .019) higher level of pain with NRS and WFPRS, increased use of ocular lubrication (P = .003), greater frequency of patients with pathological results on anxiety and depression questionnaires (P < .001), and a higher prevalence of central sensitization syndromes (P < .001). Additionally, NOP-DE patients demonstrated higher tactile corneal sensitivity post-topical anesthesia (P = .002). IVCM revealed lower nerve density (P = .049) and higher microneuroma density (P = .008) in the sub-basal nerve plexus of NOP-DE patients compared to DE patients without NOP (P = .008). Most nerve metrics correlated moderately to strongly with clinical parameters. Persistent high corneal tactile sensitivity postanesthesia, reduced nerve density, and increased microneuroma density in the central cornea may serve as diagnostic indicators for confirming NOP in patients experiencing chronic DE post-LASIK. These findings underscore the potential utility of incorporating these measures into clinical assessments to improve diagnostic accuracy and guide management strategies in this patient population.

1 April 2020 in Archivos de la Sociedad Española de Oftalmología
Verified
Journal Article
Closed access
EMElena Martínez-Plaza
Elena Martínez-Plaza
ALA. López-Miguel
A. López-Miguel
AHA. Holgueras
A. Holgueras
RBR.I. Barraquer
R.I. Barraquer
JAJ.L. Alió
J.L. Alió
MMM.J. Maldonado
M.J. Maldonado