Mikkel Elvekjaer

Dr. Mikkel Elvekjaer


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2022 in Acta Anaesthesiologica Scandinavica
Verified
Journal Article
Open access
PDF file
CHCamilla Haahr‐Raunkjaer
Camilla Haahr‐Raunkjaer
Jesper MølgaardJesper Mølgaard
Jesper Mølgaard
MEMikkel Elvekjaer
Mikkel Elvekjaer
SRSøren Straarup Rasmussen
Søren Straarup Rasmussen
MAMichael Patrick Achiam
Michael Patrick Achiam
EAEske Kvanner Aasvang
Eske Kvanner Aasvang
Background: Patients undergoing major surgery are at risk of complications, so‐called serious adverse events (SAE). Continuous monitoring may detect deteriorating patients by recording abnormal vital signs. We aimed to assess the association between abnormal vital signs inspired by Early Warning Score thresholds and subsequent SAEs in patients undergoing major abdominal surgery.Methods: Prospective observational cohort study continuously monitoring heart rate, respiratory rate, peripheral oxygen saturation, and blood pressure for up to 96 h in 500 postoperative patients admitted to the general ward. Exposure variables were vital sign abnormalities, primary outcome was any serious adverse event occurring within 30 postoperative days. The primary analysis investigated the association between exposure variables per 24 h and subsequent serious adverse events.Results: Serious adverse events occurred in 37% of patients, with 38% occurring during monitoring. Among patients with SAE during monitoring, the median duration of vital sign abnormalities was 272 min (IQR 110–447), compared to 259 min (IQR 153–394) in patients with SAE after monitoring and 261 min (IQR 132–468) in the patients without any SAE (p = .62 for all three group comparisons). Episodes of heart rate ≥110 bpm occurred in 16%, 7.1%, and 3.9% of patients in the time before SAE during monitoring, after monitoring, and without SAE, respectively (p < .002). Patients with SAE after monitoring experienced more episodes of hypotension ≤90 mm Hg/24 h (p = .001).Conclusion: Overall duration of vital sign abnormalities at current thresholds were not significantly associated with subsequent serious adverse events, but more patients with tachycardia and hypotension had subsequent serious adverse events.Trial registration: Clinicaltrials.gov, identifier NCT03491137.

11 November 2019 in Journal of Clinical Monitoring and Computing
Verified
Journal Article
Closed access
PDF file
FGfor the WARD-Project Group
for the WARD-Project Group
MEMikkel Elvekjaer
Mikkel Elvekjaer
EAEske Kvanner Aasvang
Eske Kvanner Aasvang
RORasmus M. Olsen
Rasmus M. Olsen
HSHelge B. D. Sørensen
Helge B. D. Sørensen
Christian S. MeyhoffChristian S. Meyhoff
Christian S. Meyhoff

31 January 2010 in Trends in Cardiovascular Medicine
Verified
Journal Article
Closed access
MTMarek Treiman
Marek Treiman
MEMikkel Elvekjaer
Mikkel Elvekjaer
TEThomas Engstrøm
Thomas Engstrøm
JJJan Skov Jensen
Jan Skov Jensen

1 May 2021 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
MEMikkel Elvekjaer
Mikkel Elvekjaer
CCChristian Jakob Carlsson
Christian Jakob Carlsson
SRSøren Straarup Rasmussen
Søren Straarup Rasmussen
CPCeleste Michala Porsbjerg
Celeste Michala Porsbjerg
KGKatja Grønbæk
Katja Grønbæk
Christian S. MeyhoffChristian S. Meyhoff
Christian S. Meyhoff
Objective. Wireless sensors for continuous monitoring of vital signs have potential to improve patient care by earlier detection of deterioration in general ward patients. We aimed to assess agreement between wireless and standard (wired) monitoring devices in patients hospitalized with acute exacerbation of chronic obstructive pulmonary disease (AECOPD). Approach. Paired measurements of vital signs were recorded with 15 min intervals for two hours. The primary outcome was agreement between wireless and standard monitor measurements using the Bland and Altman method to calculate bias with 95% limits of agreement (LoA). We considered LoA of less than ±5 beats min −1 (bpm) acceptable for heart rate (HR), whereas agreement of peripheral oxygen saturation (SpO 2 ), respiratory rate (RR), and blood pressure (BP) were acceptable if within ±3%-points, ±3 breaths min −1 (brpm), and ±10 mmHg, respectively. Main results. 180 sample-pairs of vital signs from 20 with AECOPD patients were recorded for comparison. The wireless versus standard monitor bias was 0.03 (LoA −3.2 to 3.3) bpm for HR measurements, 1.4% (LoA −0.7% to 3.6%) for SpO 2 , −7.8 (LoA −22.3 to 6.8) mmHg for systolic BP and −6.2 (LoA −16.8 to 4.5) mmHg for diastolic BP. The wireless versus standard monitor bias for RR measurements was 0.75 (LoA −6.1 to 7.6) brpm. Significance. Commercially available wireless monitors could accurately measure HR in patients admitted with AECOPD compared to standard wired monitoring. Agreement for SpO 2 were borderline acceptable while agreement for RR and BP should be interpreted with caution.


21 September 2020 in Acta Anaesthesiologica Scandinavica
Verified
Journal Article
Closed access
PDF file
PRPatrick S. Rasmussen
Patrick S. Rasmussen
EAEske Kvanner Aasvang
Eske Kvanner Aasvang
RORasmus M. Olsen
Rasmus M. Olsen
CHCamilla Haahr‐Raunkjaer
Camilla Haahr‐Raunkjaer
MEMikkel Elvekjaer
Mikkel Elvekjaer
Christian S. MeyhoffChristian S. Meyhoff
Christian S. Meyhoff