Suguru Kanoga

Dr. Suguru Kanoga

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2020 in Biomedical Signal Processing and Control
Verified
Journal Article
Open access
SKSuguru Kanoga
Suguru Kanoga
AKAtsunori Kanemura
Atsunori Kanemura
HAHideki Asoh
Hideki Asoh

25 July 2019 in Frontiers in Human Neuroscience
Verified
Journal Article
Open access
PDF file
MOMikito Ogino
Mikito Ogino
SKSuguru Kanoga
Suguru Kanoga
MMMasatane Muto
Masatane Muto
YMYasue Mitsukura
Yasue Mitsukura
An electroencephalogram (EEG)-based brain-computer interface (BCI) is a tool to non-invasively control computers by translating the electrical activity of the brain. This technology has the potential to provide patients who have severe generalized myopathy, such as those suffering from amyotrophic lateral sclerosis (ALS), with the ability to communicate. Recently, auditory oddball paradigms have been developed to implement more practical event-related potential (ERP)-based BCIs because they can operate without ocular activities. These paradigms generally make use of clinical (over 16-channel) EEG devices and natural sound stimuli to maintain the user's motivation during the BCI operation; however, most ALS patients who have taken part in auditory ERP-based BCIs tend to complain about the following factors: (i) total device cost and (ii) setup time. The development of a portable auditory ERP-based BCI could overcome considerable obstacles that prevent the use of this technology in communication in everyday life. To address this issue, we analyzed prefrontal single-channel EEG data acquired from a consumer-grade single-channel EEG device using a natural sound-based auditory oddball paradigm. In our experiments, EEG data was gathered from nine healthy subjects and one ALS patient. The performance of auditory ERP-based BCI was quantified under an offline condition and two online conditions. The offline analysis indicated that our paradigm maintained a high level of detection accuracy (%) and ITR (bits/min) across all subjects through a cross-validation procedure (for five commands: 70.0 ± 16.1 and 1.29 ± 0.93, for four commands: 73.8 ± 14.2 and 1.16 ± 0.78, for three commands: 78.7 ± 11.8 and 0.95 ± 0.61, and for two commands: 85.7 ± 8.6 and 0.63 ± 0.38). Furthermore, the first online analysis demonstrated that our paradigm also achieved high performance for new data in an online data acquisition stream (for three commands: 80.0 ± 19.4 and 1.16 ± 0.83). The second online analysis measured online performances on the different day of offline and first online analyses on a different day (for three commands: 62.5 ± 14.3 and 0.43 ± 0.36). These results indicate that prefrontal single-channel EEGs have the potential to contribute to the development of a user-friendly portable auditory ERP-based BCI.

1 June 2016 in Neurocomputing
Verified
Journal Article
Open access
SKSuguru Kanoga
Suguru Kanoga
MNMasaki Nakanishi
Masaki Nakanishi
YMYasue Mitsukura
Yasue Mitsukura
The effect of voluntary and involuntary eyeblinks in independent components (ICs) contributing to electroencephalographic (EEG) signals was assessed to create templates for eyeblink artifact rejection from EEG signals with small number of electrodes. Fourteen EEG and one vertical electrooculographic signals were recorded for twenty subjects during experiments that prompted subjects to blink voluntarily and involuntarily. Wavelet-enhanced independent component analysis with two markers was employed as a feature extraction scheme to investigate the effects of eyeblinks in ICs of EEG signals. Extracted features were separated into epochs and analyzed. This paper presents following characteristics: (i) voluntary and involuntary eyeblink features obtained from all channels present significant differences in the delta band; (ii) distorting effects have continued influence for 3.0–4.0s (in the occipital region, 2.0s); and (iii) eyeblink effects cease to exist after the zero-crossing four (in the occipital region, two) times, regardless of the type. Several characteristics are different between voluntary and involuntary eyeblinks in EEG signals. Therefore, any templates need both types of data for eyeblink artifact rejection if the EEG signals were obtained from small number of electrodes

3 January 2022 in Neurocomputing
Verified
Journal Article
Open access
THTakayuki Hoshino
Takayuki Hoshino
SKSuguru Kanoga
Suguru Kanoga
MTMasashi Tsubaki
Masashi Tsubaki
AAAtsushi Aoyama
Atsushi Aoyama

1 July 2021 in Biomedical Signal Processing and Control
Verified
Journal Article
Open access
SKSuguru Kanoga
Suguru Kanoga
THTakayuki Hoshino
Takayuki Hoshino
HAHideki Asoh
Hideki Asoh

1 June 2019 in Neurocomputing
Verified
Journal Article
Open access
SKSuguru Kanoga
Suguru Kanoga
AKAtsunori Kanemura
Atsunori Kanemura
HAHideki Asoh
Hideki Asoh