Hao Liu

Dr. Hao Liu


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2017 in The Spine Journal
Verified
Journal Article
Closed access
XRXin Rong
Xin Rong
BWBeiyu Wang
Beiyu Wang
CDChen Ding
Chen Ding
YDYuxiao Deng
Yuxiao Deng
HCHua Chen
Hua Chen
HLHao Liu
Hao Liu

1 October 2017 in Clinical Neurology and Neurosurgery
Verified
Journal Article
Closed access
ZLZiyang Liu
Ziyang Liu
YDYuchen Duan
Yuchen Duan
XRXin Rong
Xin Rong
BWBeiyu Wang
Beiyu Wang
HCHua Chen
Hua Chen
HLHao Liu
Hao Liu

27 June 2022 in European Radiology
Verified
Journal Article
Closed access
PDF file
XZXiang Zhang
Xiang Zhang
YYYi Yang
Yi Yang
YSYi-Wei Shen
Yi-Wei Shen
KZKe-Rui Zhang
Ke-Rui Zhang
ZJZe-Kun Jiang
Ze-Kun Jiang
HLHao Liu
Hao Liu

21 September 2022 in Frontiers in Public Health
Verified
Journal Article
Open access
XZXiang Zhang
Xiang Zhang
YYYi Yang
Yi Yang
YSYi-Wei Shen
Yi-Wei Shen
KZKe-Rui Zhang
Ke-Rui Zhang
LMLi-Tai Ma
Li-Tai Ma
HLHao Liu
Hao Liu
Background: More than 70 percent of the world's population is tortured with neck pain more than once in their vast life, of which 50–85% recur within 1–5 years of the initial episode. With medical resources affected by the epidemic, more and more people seek health-related knowledge via YouTube. This article aims to assess the quality and reliability of the medical information shared on YouTube regarding neck pain.Methods: We searched on YouTube using the keyword “neck pain” to include the top 50 videos by relevance, then divided them into five and seven categories based on their content and source. Each video was quantitatively assessed using the Journal of American Medical Association (JAMA), DISCERN, Global Quality Score (GQS), Neck Pain-Specific Score (NPSS), and video power index (VPI). Spearman correlation analysis was used to evaluate the correlation between JAMA, GQS, DISCERN, NPSS and VPI. A multiple linear regression analysis was applied to identify video features affecting JAMA, GQS, DISCERN, and NPSS.Results: The videos had a mean JAMA score of 2.56 (SD = 0.43), DISCERN of 2.55 (SD = 0.44), GQS of 2.86 (SD = 0.72), and NPSS of 2.90 (SD = 2.23). Classification by video upload source, non-physician videos had the greatest share at 38%, and sorted by video content, exercise training comprised 40% of the videos. Significant differences between the uploading sources were observed for VPI (P = 0.012), JAMA (P < 0.001), DISCERN (P < 0.001), GQS (P = 0.001), and NPSS (P = 0.007). Spearman correlation analysis showed that JAMA, DISCERN, GQS, and NPSS significantly correlated with each other (JAMA vs. DISCERN, p < 0.001, JAMA vs. GQS, p < 0.001, JAMA vs. NPSS, p < 0.001, DISCERN vs. GQS, p < 0.001, DISCERN vs. NPSS, p < 0.001, GQS vs. NPSS, p < 0.001). Multiple linear regression analysis suggested that a higher JAMA score, DISCERN, or GQS score were closely related to a higher probability of an academic, physician, non-physician or medical upload source (P < 0.005), and a higher NPSS score was associated with a higher probability of an academic source (P = 0.001) than of an individual upload source.Conclusions: YouTube videos pertaining to neck pain contain low quality, low reliability, and incomplete information. Patients may be put at risk for health complications due to inaccurate, and incomplete information, particularly during the COVID-19 crisis. Academic groups should be committed to high-quality video production and promotion to YouTube users.

1 July 2016 in Clinical Spine Surgery
Verified
Journal Article
Closed access
HCHua Chen
Hua Chen
HLHao Liu
Hao Liu
LZLi Zou
Li Zou
TLTao Li
Tao Li
QGQuan Gong
Quan Gong
QKQingquan Kong
Qingquan Kong
Study Design: This was a retrospective study. Objective: The aim of this study was to investigate the effect of Centerpiece mini-plate fixation on the complete fracture and bony fusion of the hinge side in unilateral open-door cervical expansive laminoplasty. Summary of Background Data: Cervical laminoplasty is an effective and safe surgery for cervical canal stenosis. The Centerpiece mini-plate is an instrument used to secure the laminae and maintain the cervical canal expansion. Stability of the new laminae is largely dependent on healing of the hinge side bone fracture and the degree of bony fusion. To date, few studies have reported on the effects of mini-plate fixation on these 2 important factors. Materials and Methods: Between September 2009 and March 2011, 58 patients received unilateral open-door cervical expansive laminoplasty at the authors’ hospital. The group included 47 male and 11 female patients, with a mean age of 61 (range, 35–81) years. Two hundred twenty-five laminae were fixed using the Centerpiece mini-plate (group A), whereas 62 laminae were fixed using suture suspension (group B). The rates of fracture and bony fusion of the hinge were observed using computed tomography scan and compared between the 2 groups. The complete fractures were subdivided into 4 groups based on the degree of displacement of the fractured ends: type I (no displacement), type II (mild to moderate displacement), type III (complete displacement or separation), or type IV (the hinge had collapsed into the cervical canal). Results: The number of incomplete fractures and type I to IV fractures in group A were 95, 93, 25, 8, and 4 and 29, 25, 4, 2, 2 in group B, respectively. There were no significant differences between the 2 groups in terms of complete fracture rates (P=0.309) and complete fracture type distribution (P=0.694). Group A had a significantly higher rate of bony fusion of the hinge 3 months after surgery (82% vs. 70%, P=0.042); however, this rate was not statistically significant 6 months after surgery (P=0.141). For type I complete hinge fracture, group A had higher bony fusion rates, both 3 months (86% vs. 57%, P=0.004) and 6 months (92% vs. 85%, P=0.048) postoperatively. The rates of bony fusion were also significantly different among all complete fracture types 3 months (P<0.001) and 6 months (P<0.001) postoperatively. Conclusions: Centerpiece mini-plate fixation in unilateral open-door cervical expansive laminoplasty might not increase the complete fracture rate compared with suture suspension and might promote bony fusion of type I complete hinge fractures.

17 March 2022 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
YSYi-Wei Shen
Yi-Wei Shen
YYYi Yang
Yi Yang
HLHao Liu
Hao Liu
YQYue Qiu
Yue Qiu
MLMing Li
Ming Li
FGFang-Ji Gan
Fang-Ji Gan
Introduction: Anterior cervical discectomy and fusion (ACDF) is a widely accepted surgical procedure in the treatment of cervical radiculopathy and myelopathy. A solid interbody fusion is of critical significance in achieving satisfactory outcomes after ACDF. However, the current radiographic techniques to determine the degree of fusion are inaccurate and radiative. Several animal experiments suggested that the mechanical load on the spinal instrumentation could reflect the fusion process and evaluated the stability of implant. This study aims to investigate the biomechanical changes during the fusion process and explore the feasibility of reflecting the fusion status after ACDF through the load changes borne by the interbody fusion cage.Methods: The computed tomography (CT) scans preoperatively, immediately after surgery, at 3 months, and 6 months follow-up of patients who underwent ACDF at C5/6 were used to construct the C2–C7 finite element (FE) models representing different courses of fusion stages. A 75-N follower load with 1.0-Nm moments was applied to the top of C2 vertebra in the models to simulate flexion, extension, lateral bending, and axial rotation with the C7 vertebra fixed. The Von Mises stress at the surfaces of instrumentation and the adjacent intervertebral disc and force at the facet joints were analyzed.Results: The facet contact force at C5/6 suggested a significantly stepwise reduction as the fusion proceeded while the intradiscal pressure and facet contact force of adjacent levels changed slightly. The stress on the surfaces of titanium plate and screws significantly decreased at 3 and 6 months follow-up. A markedly changed stress distribution in extension among three models was noted in different fusion stages. After solid fusion is achieved, the stress was more uniformly distributed interbody fusion in all loading conditions.Conclusions: Through a follow-up study of 6 months, the stress on the surfaces of cervical instrumentation remarkably decreased in all loading conditions. After solid intervertebral fusion formed, the stress distributions on the surfaces of interbody cage and screws were more uniform. The stress distribution in extension altered significantly in different fusion status. Future studies are needed to develop the interbody fusion device with wireless sensors to achieve longitudinal real-time monitoring of the stress distribution during the course of fusion.