The objective is to evaluate the inter-recti distance on ultrasound measurement at different locations in healthy nulliparas. Electronic databases were searched for studies describing the inter-recti distance measured by ultrasound in healthy nulliparas. We excluded studies without descriptions of the measurement position or the condition of the abdominal wall. A meta-analysis was performed to evaluate the inter-recti distance on ultrasound measurement. Seven eligible studies with 295 healthy nulliparas were included. The location of the inter-recti distance measurement by ultrasound was not uniform. The pooled data divided the measurement locations into three areas. The meta-analytic summary values of the umbilical inter-recti distance of the nulliparas was 8.77 mm (6.56–10.99 mm), the distance at the epigastric area was 7.22 mm (2.76–11.68 mm), and that at the infraumbilical area was 4.09 mm (1.55–6.64 mm). The maximal reported inter-recti distance in healthy nulliparous women is smaller than 10 mm on ultrasound measurement at all locations and the range in the umbilical area is larger than that in the epigastric, infraumbilical areas. The values for the inter-recti distance reported in this systematic review can be used as the reference of feasible and desirable distance of the rectus muscles after rectus fascia plication. The limitation was that the methodological quality of the assessment in most studies was unclear or low.
Rationale: Persistent urogenital sinus (PUG) with uterus didelphys and double vagina is a rare urogenital anomaly. The diagnosis is based on magnetic resonance examination and cystoscopy. To the best of our knowledge, there is no literature report of PUG diagnosed by ultrasound alone. Patient concern: A 23-year-old woman presented with atypical menstruation and recurrent hematuria for 13 years and recurrent lower abdominal pain for 12 years. Diagnosis: PUG was diagnosed through multiple ultrasound modalities, including transabdominal 2-dimensional ultrasound, transrectal bi-plane high-frequency ultrasound, and contrast-enhanced ultrasound. We diagnosed this malformation preoperatively by accurately measuring the length of urethra and common channel through multimodal ultrasound imaging. Interventions: Urethra separation and reconstruction, vaginal pull-through and artificial vaginoplasty, and bilateral hysterosalpingectomy were performed. Outcomes: The postoperative course was uneventful. She was urinating normally after half a year and used continuous vaginal dilatation to avoid stenosis. Lessons: PUG associated with uterus didelphys and double vagina is an extremely rare malformation of the reproductive system. Multimodal ultrasound imaging can be used to diagnose this malformation preoperatively clearly and to accurately measure the length of urethra and common channel, providing an imaging basis for preparing an operative plan.
Objectives: Endometrial peristalsis (EP) in non-pregnant uterine can be assessed by visual assessment of transvaginal ultrasound (TVUS). However, visual assessment is subjective, and the outcome depends on the sonographers and video analysts. This study aimed to create a newly developed automatic analysis algorithm for measuring the EP compared to visual assessment.Methods: A retrospective analysis was performed using the datasets from in vitro fertilization and embryo transfer (IVF-ET), who underwent the evaluation of EP by TVUS within 5 days prior to transplantation. 158 cine TVUS images were used to develop the automated analysis algorithm, and 37 cine TVUS images were evaluated by both visual and automated analysis algorithms. The algorithm was developed by applying the optical flow technology and enabled objective analysis of the number, direction, and intensity of EP.Results: The number of peristaltic waves counted by visual assessment was 4.2 ± 2.3 (mean ± standard deviation) and 4.1 ± 2.1 for doctors one and two, respectively. The number of waves counted with the algorithm was 3.6 ± 2.1 at first evaluation and 3.7 ± 2.0 at repeated evaluation. A significant difference was found between the algorithm count and visual assessment (p = 0.001, 0.002, 0.003, 0.008). The ICC values for algorithm versus manuals ranged from 0.84 to 0.96 and 0.87 to 0.96. The numbers of the cervix-to-fundus (CF), fundus-to-cervix (FC), and both cervix-to-fundal and fundus-to-cervix (CF + FC) directions of EP counted by the algorithm were 50, 52, and 32, respectively. The numbers counted by visual assessment were 43, 45, and 46, respectively. The number of EP was the same in 87% of the two algorithm counts. The number was lower between the algorithm and visual analysis (79% with complete agreement). The EP intensity assessed by the algorithm was 2.6 ± 1.1, and the peristalsis velocity was 0.147 (0.07) mm/s.Conclusion: The fully automated analysis algorithm can be used to quantify uterine peristalsis comparable to visual assessment.
To evaluate the repeatability of a novel automated technique called Smart ERA (Smart Endometrial Receptivity Analysis) for the automated segmentation and volume calculation of the endometrium in patients with normal uteri,, and to compare the agreement of endometrial volume measurements between Smart ERA, the semi-automated Virtual Organ Computer-aided Analysis (VOCAL) technique and manual segmentation. This retrospective study evaluated endometrial volume measurement in infertile patients who underwent frozen-thawed embryo transfer (FET). Transvaginal three-dimensional ultrasound scans were performed using a Resona R9 ultrasound machine. Data was collected from patients between 2021 and 2022. Patients with normal uteri and optimal ultrasound images were included. Endometrial volumes were measured using Smart ERA, VOCAL at 15° rotation, and manual segmentation. Intra-observer repeatability and agreement between techniques were assessed using the intraclass correlation coefficient (ICC) and Bland–Altman analysis. A total of 407 female patients were evaluated (mean age 33.2 ± 4.7 years). The repeatability of Smart ERA showed an ICC of 0.983 (95% CI 0.984–0.991). The agreement between Smart ERA and the manual method, Smart ERA and VOCAL, and VOCAL and the manual method, as assessed by ICC, were 0.986 (95% CI 0.977–0.990), 0.943 (95% CI 0.934–0.963), and 0.951 (95% CI 0.918–0.969), respectively. The Smart ERA technique required approximately 3 s for endometrial volume calculation, while VOCAL took around 5 min and the manual segmentation method took approximately 50 min. The Smart-ERA software, which employs a novel three-dimensional segmentation algorithm, demonstrated excellent intra-observer repeatability and high agreement with both VOCAL and manual segmentation for endometrial volume measurement in women with normal uteri. However, these findings should be interpreted with caution, as the algorithm's performance may not be generalizable to populations with different uterine characteristic. Additionally, Smart ERA required significantly less time compared to VOCAL and manual segmentation.