The current paper presents a time-resolved experimental flow investigation in a highly loaded transonic gas turbine stage operating continuously under engine representative conditions. The measurement was performed with a two-component laser-doppler-velocimeter (LDV) and a three-component stereoscopic particle-image-velocimeter (3C-PIV). Unsteady velocity data were obtained in axis perpendicular planes (LDV) and tangential planes (3C-PIV) between stator and rotor as well as downstream of the rotor. The results of the time-resolved investigation at several radii show the vortex shedding process from the trailing edges of nozzle guide vanes and rotor blades. This vortex shedding was found to be phase locked to higher harmonics of the blade passing frequency. Pressure waves evoked by reflection of the trailing edge shocks of the vanes on the passing rotor blades interact with the boundary layers on the rear suction side of the vanes and on the rotor blade surfaces while running upstream and downstream the flow. They are responsible for this phase-locking phenomenon of the shedding vortices. At midspan, the vortices shedding from stator and rotor blades were also observed by PIV. The in-plane vorticity distribution was used to discuss the wake-wake interaction indicating that wake segments from the nozzle guide vanes were chopped by the rotor blades. These chopped segments are still visible in the distributions as a pair of counter rotating vortices. The nozzle wake segments are transported through the rotor passages by the flow, influencing the vortex street of the rotor blades as they pass by with the higher velocity of the main flow. A comparison with a numerical simulation is also given.
The demand of further increased bypass ratios for turbofan engines will lead to low pressure turbines with larger diameter and lower rotational speed in conventional high-bypass aeroengine architectures. Due to that, it is necessary to guide the flow leaving the high pressure turbine to the low pressure turbine at a larger diameter without any severe loss generating separation or flow disturbances. To reduce costs and weight this turbine duct has to be as short as possible. This results in superaggressive (very high diffusion) S-shaped geometries where the boundary layers are not able to withstand the strong adverse pressure gradient, which results in flow separation. This paper describes the flow through a fully separated duct as a baseline configuration. In a next step the influence of passive flow control devices onto this separation has been investigated. Therefore, low-profile vortex generators were applied within the first bend of this S-shaped intermediate turbine diffuser in order to energize the boundary layer and further reduce or even suppress the occurring separation. This configuration was investigated downstream a transonic turbine stage. Measurements were performed by means of five-hole-probes, static wall pressure taps, and oil flow visualization at the duct endwalls. For a better understanding of the flow behavior the vortex generators were also investigated in a two-dimensional rectangular S-shaped duct using the same Mach number level. Results showed that the vortex generators reduce the separation in the 2D-duct but have no distinct influence on the separation within the turbine duct due to wakes as well as strong secondary flow effects.
This two-part paper deals with the influence of high-pressure turbine (HPT) purge flows on the aerodynamic performance of turbine center frames (TCF). Measurements were carried out in a product-representative one and a half-stage turbine test setup. Four individual purge mass flows differing in flow rate, pressure, and temperature were injected through the hub and tip, forward and aft cavities of the unshrouded HPT rotor. Two TCF designs, equipped with nonturning struts, were tested and compared. In this first part of the paper, the influence of different purge flow rates (PFR) is discussed, while in the second part of the paper, the impact of the individual hub and tip purge flows on the TCF aerodynamics is investigated. The acquired measurement data illustrate that the interaction of the ejected purge flow with the main flow enhances the secondary flow structures through the TCF duct. Depending on the PFR, the radial migration of purge air onto the strut surfaces directly impacts the loss behavior of the duct. The losses associated with the flow close to the struts and in the strut wakes are highly dependent on the relative position between the HPT vane and the strut leading edge (LE), as well as the interaction between vane wake and ejected purge flow. This first-time experimental assessment demonstrates that a reduction in the purge air requirement benefits the engine system performance by lowering the TCF total pressure loss.
This paper presents the experimental and numerical evaluation and comparison of the different flow fields downstream of a turbine center frame duct and a low-pressure turbine (LPT) stage, generated by varying the inlet flow conditions to the turbine center frame (TCF) duct. The measurements were carried out in an engine-representative two-stage two-spool test turbine facility at the Institute for Thermal Turbomachinery and Machine Dynamics at Graz University of Technology. The rig consists of a high-pressure turbine (HPT) and a LPT turbine stage, connected via a TCF with non-turning struts. Four individual high-pressure turbine purge flowrates and two low-pressure turbine purge flowrates were varied to achieve different engine-relevant TCF and LPT inlet flow conditions. The experimental data were acquired by means of five-hole-probe (5HP) area traverses upstream and downstream of the TCF and downstream of the LPT. A steady Reynolds-averaged Navier–Stokes (RANS) simulation taking all purge flows in account was used for comparison, and additional insights are gained from a numerical variation of the HPT and LPT purge flowrates. The focus of this study is on the impact of the variations in TCF inlet conditions on the secondary flow generation through the TCF duct and the carryover effects on the exit flow field and performance of the LPT stage. Existing work is limited by either investigating multistage LPT configurations with generally very few measurements behind the first stage or by not including relevant HPT secondary flow structures in setting up the LPT inflow conditions. This work addresses both of these shortcomings and presents new insight into the TCF and LPT aerodynamic behavior at varying the HPT and LPT purge flows. The results demonstrate the importance of the HPT flow structures and their evolution through the TCF duct for setting up the LPT inflow conditions and ultimately for assessing the performance of the first LPT stage.
The turbine center frame (TCF) is an inherent component of turbofan aircraft engines and is used for connecting the high-pressure turbine (HPT) to the low-pressure turbine (LPT). Its position immediately downstream of the HPT makes it susceptible to the extremely high temperatures of future engines. Despite this, fundamental knowledge of heat transfer in TCFs and the influencing factors is still missing. This paper presents a new 45-deg sector-cascade test rig specifically designed for fundamental studies of film cooling effectiveness and heat transfer coefficient in TCFs and the development and validation of a measurement technique involving infrared thermography and heating foils. Measurements of heat transfer coefficient in the TCF were taken for two purge-to-mainstream mass flow ratios corresponding to the case of no purge and nominal (to engine operation) purge. The magnitude of the heat transfer coefficients on the hub and strut surfaces was highly influenced by the various flow structures in the passage and by the velocity variation of the mainstream flow due to the “aggressive” design of the TCF. Heat transfer on the surface of the strut was mainly governed by boundary layer behavior (laminar near the leading edge and turbulent for the rest of the strut) augmented by the effect of the secondary flow structures. Measurements of film cooling effectiveness were also taken for the single case of the nominal purge. A region of high film cooling effectiveness was observed, extending from the purge cavity exit to about 40% of the passage axial length. In this region, the effectiveness decreased with increasing axial length. On the surface of the struts and fillet radii, the film cooling effectiveness was found to be zero. This was attributed to the effect of the horseshoe vortex that sweeps the purge flow away from the strut surface and dilutes it by continuously entraining hot mainstream flow.
Previous studies have indicated a potential for improving the performance of a turbine center frame (TCF) duct by optimizing the clocking position between the high-pressure turbine (HPT) vanes and TCF struts. To assess the impact of clocking on the performance, a new test vehicle with a clockable ratio of HPT vanes to TCF struts, consisting of an HPT stage (aerodynamically representative of the second-stage HPT engine), a TCF duct with nonturning struts, and a first-stage low-pressure turbine vane, was designed and tested in the transonic test turbine facility (TTTF) at Graz University of Technology. This article quantifies the performance impact of clocking and describes the mechanisms causing TCF flow field changes, leveraging both experimental and numerical data. Other areas in the TCF duct impacted by the choice of the HPT vane circumferential position including the strength of unsteady HPT-TCF interaction modes, TCF strut incidence changes, and carryover effects to the first low-pressure turbine (LPT) vane are additionally highlighted. Five-hole-probe (5HP) area traverses and kielhead-rake traverses were used to assess the flow field at the TCF exit and to calculate the pressure loss. The flow field at the TCF exit shows significant differences depending on the circumferential position of the HPT vane. A relative performance benefit of 5% was achieved. A series of unsteady RANS simulations were performed to support the measured results, understand, and characterize the relevant loss mechanisms. The observed performance improvement was related to interaction between the HPT secondary-flow structures and the TCF struts. The impact of the HPT vane clocking on the unsteady flow field downstream of the TCF was investigated using fast-response aerodynamic pressure probe (FRAPP) area traverses and analyzed by means of modal decomposition. In this way, the individual azimuthal modes were ranked by their amplitude, and a dependency of the clocking position was observed and quantified.