Peter Y. Chan

Dr. Peter Y. Chan


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 June 2020 in Anaesthesia
Verified
Journal Article
Open access
PDF file
JSJ. P. Simpson
J. P. Simpson
DWD. N. Wong
D. N. Wong
LVL. Verco
L. Verco
RCR. Carter
R. Carter
MDM. Dzidowski
M. Dzidowski
PCPeter Y. Chan
Peter Y. Chan
Summary: The COVID‐19 pandemic has led to the production of novel devices intended to protect airway managers during the aerosol‐generating procedure of tracheal intubation. Using an in‐situ simulation model, we evaluated laryngoscopist exposure of airborne particles sized 0.3 ‐ 5.0 microns using five aerosol containment devices (aerosol box; sealed box with and without suction; vertical drape; and horizontal drape) compared with no aerosol containment device. Nebulised saline was used as the aerosol‐generating model for 300 s, at which point, the devices were removed to assess particle spread. Primary outcome was the quantity and size of airborne particles measured at the level of the laryngoscopist’s head at 30, 60, 120 and 300 s, as well as 360 s (60 s after device removal). Airborne particles sizes of 0.3, 0.5, 1.0, 2.5 and 5.0 microns were quantified using an electronic airborne particle counter. Compared with no device use, the sealed intubation box with suction resulted in a decrease in 0.3, 0.5, 1.0 and 2.5 micron, but not 5.0 micron, particle exposure over all time‐periods (p = 0.003 for all time periods). Compared with no device use, the aerosol box showed an increase in 1.0, 2.5 and 5.0 micron airborne particle exposure at 300 s (p = 0.002, 0.008, 0.002, respectively). Compared with no device use, neither horizontal nor vertical drapes showed any difference in any particle size exposure at any time. Finally, when the patient coughed, use of the aerosol box resulted in a marked increase in airborne particle exposure compared with other devices or no device use. In conclusion, novel devices intended to protect the laryngoscopist require objective testing to ensure they are fit for purpose and do not result in increased airborne particle exposure.

1 April 2006 in Arteriosclerosis, Thrombosis, and Vascular Biology
Verified
Journal Article
Closed access
PDF file
KRKenneth John Rodgers
Kenneth John Rodgers
DWDeborah J. Watkins
Deborah J. Watkins
AMAlastair L. Miller
Alastair L. Miller
PCPeter Y. Chan
Peter Y. Chan
SKSharada Karanam
Sharada Karanam
CJChristopher L. Jackson
Christopher L. Jackson
Objective— Lysosomal proteinases have been implicated in a number of pathologies associated with extracellular matrix breakdown. Therefore, we investigated the possibility that the lysosomal proteinase cathepsin S may be involved in atherosclerotic plaque destabilization. Methods and Results— Atherosclerotic plaques in the brachiocephalic arteries of fat-fed apolipoprotein E/cathepsin S double knockout mice had 73% fewer acute plaque ruptures ( P =0.026) and were 46% smaller ( P =0.025) than those in age-, strain-, and sex-matched apolipoprotein E single knockout controls. When the incidence of acute plaque rupture was normalized for plaque size, the reduction in the double knockouts was 72% ( P =0.039). The number of buried fibrous layers, indicative of an unstable plaque phenotype, was reduced by 67% in the double knockouts ( P =0.008). The cysteine proteinase inhibitor, egg white cystatin, was biotinylated and used as an active-site-directed probe for cathepsins. Biotinylated cystatin selectively detected cathepsin S in extracts of human carotid atherosclerotic plaque. Active cathepsin S was detectable in extracts of human atherosclerotic plaque but not in nondiseased carotid arteries. Active cathepsins were especially prominent in macrophages in the shoulder regions of plaques, areas considered to be vulnerable to rupture. Cathepsin S protein colocalized with regions of elastin degradation in human coronary plaques. Conclusion— These data provide direct evidence that an endogenous proteinase, cathepsin S, plays an important role in atherosclerotic plaque destabilization and rupture.

1 October 2017 in Anesthesia & Analgesia
Verified
Journal Article
Closed access
PCPeter Y. Chan
Peter Y. Chan
SSSimon Scharf
Simon Scharf
This pilot study assessed the feasibility and potential for any possible sedation sparing effect of immersive virtual reality (IVR) therapy on patients undergoing joint replacement surgery under regional anesthesia. Nine participants were given IVR, regional anesthetic, and sedation. Ten received conventional care. Mean propofol usage was 155 ± 45 mg/h in the conventional care group and 63 ± 21 mg/h in the IVR group (P = .088, mean difference −91.6 mg/h, 95% confidence interval, −200 to 16.87 mg/h). There was no significant difference in postoperative satisfaction between the 2 groups. This pilot study demonstrates that it is possible to safely provide IVR in an operating theater environment and may confer a sedation sparing effect. A larger, more powered, and randomized study is needed to assess this effect.

21 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Simon LyraSimon Lyra
Simon Lyra
LMLeon Mayer
Leon Mayer
Liyang OuLiyang Ou
Liyang Ou
DCDavid Chen
David Chen
PTPaddy Timms
Paddy Timms
Christoph Hoog AntinkChristoph Hoog Antink
Christoph Hoog Antink
Infrared thermography for camera-based skin temperature measurement is increasingly used in medical practice, e.g., to detect fevers and infections, such as recently in the COVID-19 pandemic. This contactless method is a promising technology to continuously monitor the vital signs of patients in clinical environments. In this study, we investigated both skin temperature trend measurement and the extraction of respiration-related chest movements to determine the respiratory rate using low-cost hardware in combination with advanced algorithms. In addition, the frequency of medical examinations or visits to the patients was extracted. We implemented a deep learning-based algorithm for real-time vital sign extraction from thermography images. A clinical trial was conducted to record data from patients on an intensive care unit. The YOLOv4-Tiny object detector was applied to extract image regions containing vital signs (head and chest). The infrared frames were manually labeled for evaluation. Validation was performed on a hold-out test dataset of 6 patients and revealed good detector performance (0.75 intersection over union, 0.94 mean average precision). An optical flow algorithm was used to extract the respiratory rate from the chest region. The results show a mean absolute error of 2.69 bpm. We observed a computational performance of 47 fps on an NVIDIA Jetson Xavier NX module for YOLOv4-Tiny, which proves real-time capability on an embedded GPU system. In conclusion, the proposed method can perform real-time vital sign extraction on a low-cost system-on-module and may thus be a useful method for future contactless vital sign measurements.

9 February 2011 in Breast Cancer Research
Verified
Journal Article
Open access
PDF file
PCPeter Y. Chan
Peter Y. Chan
Andreas MöllerAndreas Möller
Andreas Möller
MLMira Cp Liu
Mira Cp Liu
JSJaclyn E Sceneay
Jaclyn E Sceneay
CWChristina Sf Wong
Christina Sf Wong
SFStephen Fox
Stephen Fox
The seven in absentia homolog 2 (SIAH2) protein plays a significant role in the hypoxic response by regulating the abundance of hypoxia-inducible factor-α; however, its role in breast carcinoma is unclear. We investigated the frequency and expression pattern of SIAH2 in two independent cohorts of sporadic breast cancers.

24 February 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MHMark Y Huang
Mark Y Huang
SSSimon Scharf
Simon Scharf
PCPeter Y. Chan
Peter Y. Chan
Immersive virtual reality (IVR) is a form of distraction therapy that has shown potential as an analgesia and sedation sparing agent. This study assessed the effect of IVR on the self-administered sedation requirements of patients undergoing joint replacement surgery under regional anesthesia in a single center. This study was a single-center, randomized control trial at St Vincent’s Hospital in Melbourne, Australia. Fifty patients undergoing elective total knee and total hip arthroplasty were randomized to IVR and Propofol patient-controlled sedation (PCS) or propofol PCS alone. The primary outcome measure was intra-operative propofol use. Secondary outcomes included pattern of propofol use over time, use of adjunct analgesia, unmet propofol demand, and patient satisfaction survey scores. Of 50 total patients, 25 received IVR in conjunction with PCS, and 25 received PCS alone. All patients received adjunct analgesia from the treating Anesthesiologist. Median propofol use/hour over the entire procedure in the control group was 40 (11.1, 93.9) mg/hour compared with 45 (0, 94.7) mg/hour in the IVR group (p = 0.90). There were no differences in patterns of propofol use over the course of each procedure. Adjusting for various baseline characteristics did not change the results. Postoperative satisfaction scores were equivalent in both groups. The VR intervention was well tolerated by all patients, with no report of major side effects. Key limitations were relatively small sample size, the non-blinded nature of the study, and use of adjunct analgesia. In patients receiving joint replacement surgery under regional anesthesia with PCS, IVR was well tolerated but did not decrease the overall sedation requirement.