Pieter Ginis

Dr. Pieter Ginis

KU Leuven, Department of Rehabilitation Sciences, Neurorehabilitation Research Group (eNRGy), Leuven, Belgium
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2016 in Cochrane Database of Systematic Reviews
Verified
Journal Article
Closed access
PDF file
KDKim Dockx
Kim Dockx
EBEsther Mj Bekkers
Esther Mj Bekkers
VBVeerle Van Den Bergh
Veerle Van Den Bergh
Pieter GinisPieter Ginis
Pieter Ginis
LRLynn Rochester
Lynn Rochester
ANAlice Nieuwboer
Alice Nieuwboer

1 November 2018 in Annals of Physical and Rehabilitation Medicine
Verified
Journal Article
Closed access
Pieter GinisPieter Ginis
Pieter Ginis
ENEvelien Nackaerts
Evelien Nackaerts
ANAlice Nieuwboer
Alice Nieuwboer
EHElke Heremans
Elke Heremans

3 May 2019 in European Review of Aging and Physical Activity
Verified
Journal Article
Open access
PDF file
IHInbar Hillel
Inbar Hillel
EGEran Gazit
Eran Gazit
ANAlice Nieuwboer
Alice Nieuwboer
LALaura Avanzino
Laura Avanzino
LRLynn Rochester
Lynn Rochester
Jeffrey HausdorffJeffrey Hausdorff
Jeffrey Hausdorff
The traditional evaluation of gait in the laboratory during structured testing has provided important insights, but is limited by its “snapshot” character and observation in an unnatural environment. Wearables enable monitoring of gait in real-world environments over a week. Initial findings show that in-lab and real-world measures differ. As a step towards better understanding these gaps, we directly compared in-lab usual-walking (UW) and dual-task walking (DTW) to daily-living measures of gait. In-lab gait features (e.g., gait speed, step regularity, and stride regularity) derived from UW and DTW were compared to the same gait features during daily-living in 150 elderly fallers (age: 76.5 ± 6.3 years, 37.6% men). In both settings, features were extracted from a lower-back accelerometer. In the real-world setting, subjects were asked to wear the device for 1 week and pre-processing detected 30-s daily-living walking bouts. A histogram of all walking bouts was determined for each walking feature for each subject and then each subject’s typical (percentile 50, median), worst (percentile 10) and the best (percentile 90) values over the week were determined for each feature. Statistics of reliability were assessed using Intra-Class correlations and Bland-Altman plots. As expected, in-lab gait speed, step regularity, and stride regularity were worse during DTW, compared to UW. In-lab gait speed, step regularity, and stride regularity during UW were significantly higher (i.e., better) than the typical daily-living values (p < 0.001) and different (p < 0.001) from the worst and best values. DTW values tended to be similar to typical daily-living values (p = 0.205, p = 0.053, p = 0.013 respectively). ICC assessment and Bland-Altman plots indicated that in-lab values do not reliably reflect the daily-walking values. Gait values measured during relatively long (30-s) daily-living walking bouts are more similar to the corresponding values obtained in the lab during dual-task walking, as compared to usual walking. Still, gait performance during most daily-living walking bouts is worse than that measured during usual and dual-tasking in the lab. The values measured in the lab do not reliably reflect daily-living measures. That is, an older adult’s typical daily-living gait cannot be estimated by simply measuring walking in a structured, laboratory setting.

1 January 2016 in Parkinsonism & Related Disorders
Verified
Journal Article
Closed access
Pieter GinisPieter Ginis
Pieter Ginis
ANAlice Nieuwboer
Alice Nieuwboer
MDMoran Dorfman
Moran Dorfman
AFAlberto Ferrari
Alberto Ferrari
EGEran Gazit
Eran Gazit
AMAnat Mirelman
Anat Mirelman

30 July 2015 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
AFAlberto Ferrari
Alberto Ferrari
Pieter GinisPieter Ginis
Pieter Ginis
MHMichael Hardegger
Michael Hardegger
FCFilippo Casamassima
Filippo Casamassima
LRLaura Rocchi
Laura Rocchi
Lorenzo ChiariLorenzo Chiari
Lorenzo Chiari
Gait impairments are among the most disabling symptoms in several musculoskeletal and neurological conditions, severely limiting personal autonomy. Wearable gait sensors have been attracting attention as diagnostic tool for gait and are emerging as promising tool for tutoring and guiding gait execution. If their popularity is continuously growing, still there is room for improvement, especially towards more accurate solutions for spatio-temporal gait parameters estimation. We present an implementation of a zero-velocity-update gait analysis system based on a Kalman filter and off-the-shelf shoe-worn inertial sensors. The algorithms for gait events and step length estimation were specifically designed to comply with pathological gait patterns. More so, an Android app was deployed to support fully wearable and stand-alone real-time gait analysis. Twelve healthy subjects were enrolled to preliminarily tune the algorithms; afterwards sixteen persons with Parkinson's disease were enrolled for a validation study. Over the 1314 strides collected on patients at three different speeds, the total root mean square difference on step length estimation between this system and a gold standard was 2.9%. This shows that the proposed method allows for an accurate gait analysis and paves the way to a new generation of mobile devices usable anywhere for monitoring and intervention.

28 March 2014 in Sensors
Verified
Journal Article
Open access
PDF file
FCFilippo Casamassima
Filippo Casamassima
AFAlberto Ferrari
Alberto Ferrari
BMBojan Milosevic
Bojan Milosevic
Pieter GinisPieter Ginis
Pieter Ginis
EFElisabetta Farella
Elisabetta Farella
LRLaura Rocchi
Laura Rocchi
In this paper, a system for gait training and rehabilitation for Parkinson’s disease (PD) patients in a daily life setting is presented. It is based on a wearable architecture aimed at the provision of real-time auditory feedback. Recent studies have, in fact, shown that PD patients can receive benefit from a motor therapy based on auditory cueing and feedback, as happens in traditional rehabilitation contexts with verbal instructions given by clinical operators. To this extent, a system based on a wireless body sensor network and a smartphone has been developed. The system enables real-time extraction of gait spatio-temporal features and their comparison with a patient’s reference walking parameters captured in the lab under clinical operator supervision. Feedback is returned to the user in form of vocal messages, encouraging the user to keep her/his walking behavior or to correct it. This paper describes the overall concept, the proposed usage scenario and the parameters estimated for the gait analysis. It also presents, in detail, the hardware-software architecture of the system and the evaluation of system reliability by testing it on a few subjects.