Samar M. Adel

Dr. Samar M. Adel

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in BioMed Research International
Verified
Journal Article
Open access
PDF file
SASamar M. Adel
Samar M. Adel
AZAbbas Zaher
Abbas Zaher
NHNadia El Harouni
Nadia El Harouni
AVADITH VENUGOPAL
ADITH VENUGOPAL
PPPratik Premjani
Pratik Premjani
NVNikhilesh R Vaid
Nikhilesh R Vaid
The last decade (2010‐2021) has witnessed the evolution of robotic applications in orthodontics. This review scopes and analyzes published orthodontic literature in eight different domains: (1) robotic dental assistants; (2) robotics in diagnosis and simulation of orthodontic problems; (3) robotics in orthodontic patient education, teaching, and training; (4) wire bending and customized appliance robotics; (5) nanorobots/microrobots for acceleration of tooth movement and for remote monitoring; (6) robotics in maxillofacial surgeries and implant placement; (7) automated aligner production robotics; and (8) TMD rehabilitative robotics. A total of 1,150 records were searched, of which 124 potentially relevant articles were retrieved in full. 87 studies met the selection criteria following screening and were included in the scoping review. The review found that studies pertaining to arch wire bending and customized appliance robots, simulative robots for diagnosis, and surgical robots have been important areas of research in the last decade (32%, 22%, and 16%). Rehabilitative robots and nanorobots are quite promising and have been considerably reported in the orthodontic literature (13%, 9%). On the other hand, assistive robots, automated aligner production robots, and patient robots need more scientific data to be gathered in the future (1%, 1%, and 6%). Technological readiness of different robotic applications in orthodontics was further assessed. The presented eight domains of robotic technologies were assigned to an estimated technological readiness level according to the information given in the publications. Wire bending robots, TMD robots, nanorobots, and aligner production robots have reached the highest levels of technological readiness: 9; diagnostic robots and patient robots reached level 7, whereas surgical robots and assistive robots reached lower levels of readiness: 4 and 3, respectively.

31 March 2022 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
SASamar M. Adel
Samar M. Adel
NVNikhilesh R Vaid
Nikhilesh R Vaid
NENadia El-Harouni
Nadia El-Harouni
HKHassan Kassem
Hassan Kassem
AZAbbas R. Zaher
Abbas R. Zaher
Background: To evaluate the accuracy of three different 3D digital model registration software packages for linear tooth movement measurements, with reference to a 3D digital virtual setup (DS). Methods: Twenty maxillary and mandibular pre-treatment scans of patients undergoing clear aligner therapy were used. Digital Setups were generated from pre-treatment scans using OrthoAnalyzer software. Both the pretreatment digital scans (T1) and Digital Setups (T2) were converted to STL files to be imported to the three studied software packages: Geomagic, OrthoAnalyzer and Compare. Linear changes in tooth positions were calculated for all the registered pairs. Results: The change in tooth position was compared between the calculated tooth movement using each of the registration software packages versus the actual generated tooth movement from the Digital Setups. Continuous data was expressed as mean and standard deviation. Intraclass Correlation Coefficients for agreements between Digital Simulation and each software was used. Intra and Inter-examiner reliabilities were also assessed using Intraclass Correlation Coefficients. Significance of the obtained results was expressed at p ≤ 0.01. Geomagic software showed agreements > 0.90 for maxillary linear tooth movements and between 0.75 and 0.90 for mandibular measurements. OrthoAnalyzer software showed agreements between 0.50 and < 0.75 for maxillary and mandibular measurements. Compare software showed agreements > 0.90 for maxillary and mandibular linear tooth movements, indicating the best consistency. Conclusions: Compare and Geomagic software packages consistently showed maximum accuracy in measuring the amount of tooth movement in the maxillary arch compared to the reference standard. Compare software showed the highest agreements in the mandibular arch. None of the three studied software packages showed poor agreement with the Digital Setup across all tooth movement measurements. Buccolingual tooth movements showed the highest agreements amongst linear measurements.

14 March 2022 in Progress in Orthodontics
Verified
Journal Article
Open access
PDF file
SASamar M. Adel
Samar M. Adel
NVNikhilesh R Vaid
Nikhilesh R Vaid
NENadia El-Harouni
Nadia El-Harouni
HKHassan Kassem
Hassan Kassem
AZAbbas R. Zaher
Abbas R. Zaher
Background: To investigate the accuracy of three different 3D digital model registration software for tip, torque and rotation measurements, with reference to a 3D digital virtual setup. Twenty maxillary and mandibular pre-treatment scans of patients undergoing clear aligner therapy were used. Digital setups were generated from pre-treatment scans using a tooth movement software. Both the pretreatment digital scans (T1) and digital setups (T2) were converted to STL files to be exported to the 3 studied software that employed: (1) Semiautomatic best fit registration (S-BF), (2) Interactive surface-based registration (I-SB), and (3) Automatic best fit registration (A-BF) respectively. Changes in tip, torque and rotation were calculated for all the registered pairs. Results: The change in tooth position was compared between the calculated tooth movement using each of the registration software packages versus the actual generated tooth movement from the digital setups. Continuous data was expressed as mean and standard deviation. Intra Class Correlation Coefficient for agreement between digital simulation and each software was used. Intra and Inter-examiner reliabilities were also assessed using Intra Class Correlation Coefficient. Significance of the obtained results was expressed at p ≤ 0.01. Semiautomatic best fit registration software showed excellent agreement (> 0.90) for all tooth movements, except for good agreement for torque (0.808). Interactive surface-based registration software showed moderate agreement for all measurements (0.50 and < 0.75), except for good agreement for rotation (0.783). Automatic best fit registration software demonstrated excellent agreement (> 0.90) for rotation, good agreement for tip (0.890) and moderate agreement for torque (0.740). Conclusions: Overall, semiautomatic best fit registration software consistently showed excellent agreement in superimpositions compared to other software types. Automatic best fit registration software consistently demonstrated better agreement for mandibular superimpositions, compared to others. Accuracy of digital model superimpositions for tooth movements studied in superimposition studies, can be attributed to the algorithm employed for quantification.

17 July 2023 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
AMAbraham McKay
Abraham McKay
JMJulie McCray
Julie McCray
BBBrent Bankhead
Brent Bankhead
MLMichael Lee
Michael Lee
GMGabriel Gabriel Miranda
Gabriel Gabriel Miranda
Ki Beom KimKi Beom Kim
Ki Beom Kim
Objective: To assess the possibility of extrusion of a maxillary central incisor with the use of buccal and lingual pressure columns in the absence of attachments, and to evaluate the forces and moments experienced by the teeth using both thermoformed and 3D-printed clear aligners. Materials and methods: A three-axis force and moment sensor (Aidin Robotics, Anyang, South Korea) was used to measure the forces and moments during extrusion of an upper left central incisor (UL1) and any forces experienced by the upper right central incisor (UR1) using thermoformed aligners and 3D-printed aligners. For the thermoformed aligners, the materials used were ATMOS® (American Orthodontics, Sheboygan, WI) and Zendura FLX® (Bay Materials LLC, Fremont, CA). 3D-printed aligners were fabricated using TC-85 clear photocurable resin (Graphy Inc., Seoul, South Korea). For each material type, three conditions were tested: Group 1: No attachment or pressure columns (control); Group 2: Attachment only; and Group 3: Pressure columns only. Each group was planned for 0.5 mm of extrusion on the UL1. Results: All force readings collected demonstrated statistically significant differences when compared by materials and when compared by groups, with a P value of < 0.001. In the absence of attachment or pressure columns (Group 1), ATMOS® and TC-85 groups exerted extrusive force on the UL1. However, significantly lower forces and moments were exerted by the TC-85 group in comparison to the ATMOS® and Zendura FLX® groups. In the presence of attachment (Group 2), all three ATMOS®, Zendura FLX® and TC-85 groups exerted extrusive force on the UL1, with the TA group showing different directions of faciolingual force, mesiodistal force and faciolingual inclination on the UR1 when compared to the other two thermoformed groups. Whereas in the presence of pressure columns (Group 3), only the TC-85 3D-printed aligner group exerted extrusive force. Thermoformed aligners generated significantly higher mean forces and moments than 3D-printed aligners. Significant levels of unintended forces and moments were present in all groups. Conclusions: Force levels generated during extrusion with clear aligners are significantly lower with those 3D-printed using TC-85 than with those thermoformed using ATMOS® or Zendura FLX®. Attachments consistently generated extrusive forces, and may be an effective adjunct in achieving extrusion of incisors. Extrusion may be achieved without the use of attachments by utilizing pressure columns in 3D-printed aligners using TC-85. While different strategies can generate extrusive forces, there are significant unintended forces and moments.

15 November 2022 in Journal of the World Federation of Orthodontists
Verified
Journal Article
Closed access
NVNikhilesh R Vaid
Nikhilesh R Vaid
WSWaddah Sabouni
Waddah Sabouni
BWBenedict Wilmes
Benedict Wilmes
YBYashodhan M. Bichu
Yashodhan M. Bichu
DTDigant P. Thakkar
Digant P. Thakkar
SASamar M. Adel
Samar M. Adel

19 January 2023 in Seminars in Orthodontics
Verified
Journal Article
Closed access
PDF file
SASamar M. Adel
Samar M. Adel
NENadia El-Harouni
Nadia El-Harouni
NVNikhilesh R Vaid
Nikhilesh R Vaid