Matthew W Urban

Dr. Matthew W Urban

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2013 in Ultrasound in Medicine & Biology
Verified
Journal Article
Open access
ASArmen P. Sarvazyan
Armen P. Sarvazyan
MUMatthew W Urban
Matthew W Urban
JGJames F. Greenleaf
James F. Greenleaf
Up until about two decades ago acoustic imaging and ultrasound imaging were synonymous. The term ultrasonography, or its abbreviated version sonography, meant an imaging modality based on the use of ultrasonic compressional bulk waves. Beginning in the 1990s, there started to emerge numerous acoustic imaging modalities based on the use of a different mode of acoustic wave: shear waves. Imaging with these waves was shown to provide very useful and very different information about the biological tissue being examined. We discuss the physical basis for the differences between these two basic modes of acoustic waves used in medical imaging and analyze the advantages associated with shear acoustic imaging. A comprehensive analysis of the range of acoustic wavelengths, velocities and frequencies that have been used in different imaging applications is presented. We discuss the potential for future shear wave imaging applications.

1 March 2011 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
MBMiguel Bernal
Miguel Bernal
INIvan Nenadic
Ivan Nenadic
MUMatthew W Urban
Matthew W Urban
JGJames F. Greenleaf
James F. Greenleaf
Arterial elasticity has been proposed as an independent predictor of cardiovascular diseases and mortality. Identification of the different propagating modes in thin shells can be used to characterize the elastic properties. Ultrasound radiation force was used to generate local mechanical waves in the wall of a urethane tube or an excised pig carotid artery. The waves were tracked using pulse-echo ultrasound. A modal analysis using two-dimensional discrete fast Fourier transform was performed on the time–space signal. This allowed the visualization of different modes of propagation and characterization of dispersion curves for both structures. The urethane tube/artery was mounted in a metallic frame, embedded in tissue-mimicking gelatin, cannulated, and pressurized over a range of 10–100 mmHg. The k-space and the dispersion curves of the urethane tube showed one mode of propagation, with no effect of transmural pressure. Fitting of a Lamb wave model estimated Young’s modulus in the urethane tube around 560 kPa. Young’s modulus of the artery ranged from 72 to 134 kPa at 10 and 100 mmHg, respectively. The changes observed in the artery dispersion curves suggest that this methodology of exciting mechanical waves and characterizing the modes of propagation has potential for studying arterial elasticity.

14 March 2011 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
INIvan Z Nenadic
Ivan Z Nenadic
MUMatthew W Urban
Matthew W Urban
SMScott A Mitchell
Scott A Mitchell
JGJames F Greenleaf
James F Greenleaf
Diastolic dysfunction is the inability of the left ventricle to supply sufficient stroke volumes under normal physiological conditions and is often accompanied by stiffening of the left-ventricular myocardium. A noninvasive technique capable of quantifying viscoelasticity of the myocardium would be beneficial in clinical settings. Our group has been investigating the use of shear wave dispersion ultrasound vibrometry (SDUV), a noninvasive ultrasound-based method for quantifying viscoelasticity of soft tissues. The primary motive of this study is the design and testing of viscoelastic materials suitable for validation of the Lamb wave dispersion ultrasound vibrometry (LDUV), an SDUV-based technique for measuring viscoelasticity of tissues with plate-like geometry. We report the results of quantifying viscoelasticity of urethane rubber and gelatin samples using LDUV and an embedded sphere method. The LDUV method was used to excite antisymmetric Lamb waves and measure the dispersion in urethane rubber and gelatin plates. An antisymmetric Lamb wave model was fitted to the wave speed dispersion data to estimate elasticity and viscosity of the materials. A finite element model of a viscoelastic plate submerged in water was used to study the appropriateness of the Lamb wave dispersion equations. An embedded sphere method was used as an independent measurement of the viscoelasticity of the urethane rubber and gelatin. The FEM dispersion data were in excellent agreement with the theoretical predictions. Viscoelasticity of the urethane rubber and gelatin obtained using the LDUV and embedded sphere methods agreed within one standard deviation. LDUV studies on excised porcine myocardium sample were performed to investigate the feasibility of the approach in preparation for open-chest in vivo studies. The results suggest that the LDUV technique can be used to quantify the mechanical properties of soft tissues with a plate-like geometry.

1 November 2011 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
HZHeng Zhao
Heng Zhao
PSPengfei Song
Pengfei Song
MUMatthew W Urban
Matthew W Urban
RKRandall R. Kinnick
Randall R. Kinnick
MYMeng Yin
Meng Yin
SCShigao Chen
Shigao Chen

12 April 2013 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
PSPengfei Song
Pengfei Song
MUMatthew W Urban
Matthew W Urban
AMArmando Manduca
Armando Manduca
HZHeng Zhao
Heng Zhao
JGJames F. Greenleaf
James F. Greenleaf
SCShigao Chen
Shigao Chen
Comb-push ultrasound shear elastography (CUSE) has recently been shown to be a fast and accurate 2-D elasticity imaging technique that can provide a full field-of-view (FOV) shear wave speed map with only one rapid data acquisition. The initial version of CUSE was termed U-CUSE because unfocused ultrasound push beams were used. In this paper, we present two new versions of CUSE-focused CUSE (F-CUSE) and marching CUSE (M-CUSE), which use focused ultrasound push beams to improve acoustic radiation force penetration and produce stronger shear waves in deep tissues (e.g., kidney and liver). F-CUSE divides transducer elements into several subgroups which transmit multiple focused ultrasound beams simultaneously. M-CUSE uses more elements for each focused push beam and laterally marches the push beams. Both F-CUSE and M-CUSE can generate comb-shaped shear wave fields that have shear wave motion at each imaging pixel location so that a full FOV 2-D shear wave speed map can be reconstructed with only one data acquisition. Homogeneous phantom experiments showed that U-CUSE, F-CUSE, and M-CUSE can all produce smooth shear wave speed maps with accurate shear wave speed estimates. An inclusion phantom experiment showed that all CUSE methods could provide good contrast between the inclusion and background with sharp boundaries while F-CUSE and M-CUSE require shorter push durations to achieve shear wave speed maps with comparable SNR to U-CUSE. A more challenging inclusion phantom experiment with a very stiff and deep inclusion shows that better shear wave penetration could be gained by using F-CUSE and M-CUSE. Finally, a shallow inclusion experiment showed that good preservations of inclusion shapes could be achieved by both U-CUSE and F-CUSE in the near field. Safety measurements showed that all safety parameters are below FDA regulatory limits for all CUSE methods. These promising results suggest that, using various push beams, CUSE is capable of reconstructing a 2-D full FOV shear elasticity map using only one push-detection data acquisition in a wide range of depths for soft tissue elasticity imaging.

1 February 2012 in Current Medical Imaging
Verified
Journal Article
Closed access
PDF file
MUMatthew W Urban
Matthew W Urban
SCShigao Chen
Shigao Chen
MFMostafa Fatemi
Mostafa Fatemi
Measurement of tissue elasticity has emerged as an important advance in medical imaging and tissue characterization. However, soft tissue is inherently a viscoelastic material. One way to characterize the viscoelastic material properties of a material is to measure shear wave propagation velocities within the material at different frequencies and use the dispersion of the velocities, or variation with frequency, to solve for the material properties. Shearwave Dispersion Ultrasound Vibrometry (SDUV) is an ultrasound-based technique that uses this feature to characterize the viscoelastic nature of soft tissue. This method has been used to measure the shear elasticity and viscosity in various types of soft tissues including skeletal muscle, cardiac muscle, liver, kidney, prostate, and arterial vessels. This versatile technique provides measurements of viscoelastic material properties with high spatial and temporal resolution, which can be used for assessing these properties in normal and pathologic tissues. The goals of this paper are to 1) give an overview of viscoelasticity and shear wave velocity dispersion, 2) provide a history of the development of the SDUV method, and 3) survey applications for SDUV that have been previously reported.