Jelle Himmelreich

Dr. Jelle Himmelreich

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2020 in EP Europace
Verified
Journal Article
Open access
JHJelle Himmelreich
Jelle Himmelreich
LVLieke Veelers
Lieke Veelers
WLWim A M Lucassen
Wim A M Lucassen
RSRenate B Schnabel
Renate B Schnabel
MRMichiel Rienstra
Michiel Rienstra
RHRalf E Harskamp
Ralf E Harskamp
Aims: Atrial fibrillation (AF) is a common arrhythmia associated with an increased stroke risk. The use of multivariable prediction models could result in more efficient primary AF screening by selecting at-risk individuals. We aimed to determine which model may be best suitable for increasing efficiency of future primary AF screening efforts.Methods and results: We performed a systematic review on multivariable models derived, validated, and/or augmented for AF prediction in community cohorts using Pubmed, Embase, and CINAHL (Cumulative Index to Nursing and Allied Health Literature) through 1 August 2019. We performed meta-analysis of model discrimination with the summary C-statistic as the primary expression of associations using a random effects model. In case of high heterogeneity, we calculated a 95% prediction interval. We used the CHARMS (Critical Appraisal and Data Extraction for Systematic Reviews of Prediction Modelling Studies) checklist for risk of bias assessment. We included 27 studies with a total of 2 978 659 unique participants among 20 cohorts with mean age ranging from 42 to 76 years. We identified 21 risk models used for incident AF risk in community cohorts. Three models showed significant summary discrimination despite high heterogeneity: CHARGE-AF (Cohorts for Heart and Aging Research in Genomic Epidemiology) [summary C-statistic 0.71; 95% confidence interval (95% CI) 0.66–0.76], FHS-AF (Framingham Heart Study risk score for AF) (summary C-statistic 0.70; 95% CI 0.64–0.76), and CHA2DS2-VASc (summary C-statistic 0.69; 95% CI 0.64–0.74). Of these, CHARGE-AF and FHS-AF had originally been derived for AF incidence prediction. Only CHARGE-AF, which comprises easily obtainable measurements and medical history elements, showed significant summary discrimination among cohorts that had applied a uniform (5-year) risk prediction window.Conclusion: CHARGE-AF appeared most suitable for primary screening purposes in terms of performance and applicability in older community cohorts of predominantly European descent.

9 September 2019 in The Annals of Family Medicine
Verified
Journal Article
Closed access
PDF file
JHJelle Himmelreich
Jelle Himmelreich
EKEvert P.M. Karregat
Evert P.M. Karregat
WLWim A.M. Lucassen
Wim A.M. Lucassen
HWHenk C.P.M. van Weert
Henk C.P.M. van Weert
JGJoris De Groot
Joris De Groot
RHRalf E. Harskamp
Ralf E. Harskamp
PURPOSE To validate a smartphone-operated, single-lead electrocardiography (1L-ECG) device (AliveCor KardiaMobile) with an integrated algorithm for atrial fibrillation (AF) against 12-lead ECG (12L-ECG) in a primary care population. METHODS We recruited consecutive patients who underwent 12L-ECG for any nonacute indication. Patients held a smartphone with connected 1L-ECG while local personnel simultaneously performed 12L-ECG. All 1L-ECG recordings were assessed by blinded cardiologists as well as by the smartphone-integrated algorithm. The study cardiologists also assessed all 12L-recordings in random order as the reference standard. We determined the diagnostic accuracy of the 1L-ECG in detecting AF or atrial flutter (AFL) as well as any rhythm abnormality and any conduction abnormality with the simultaneously performed 12L-ECG as the reference standard. RESULTS We included 214 patients from 10 Dutch general practices. Mean ± SD age was 64.1 ± 14.7 years, and 53.7% of the patients were male. The 12L-ECG diagnosed AF/AFL, any rhythm abnormality, and any conduction abnormality in 23, 44, and 28 patients, respectively. The 1L-ECG as assessed by cardiologists had a sensitivity and specificity for AF/AFL of 100% (95% CI, 85.2%-100%) and 100% (95% CI, 98.1%-100%). The AF detection algorithm had a sensitivity and specificity of 87.0% (95% CI, 66.4%-97.2%) and 97.9% (95% CI, 94.7%-99.4%). The 1L-ECG as assessed by cardiologists had a sensitivity and specificity for any rhythm abnormality of 90.9% (95% CI, 78.3%-97.5%) and 93.5% (95% CI, 88.7%-96.7%) and for any conduction abnormality of 46.4% (95% CI, 27.5%-66.1%) and 100% (95% CI, 98.0%-100%). CONCLUSIONS In a primary care population, a smartphone-operated, 1L-ECG device showed excellent diagnostic accuracy for AF/AFL and good diagnostic accuracy for other rhythm abnormalities. The 1L-ECG device was less sensitive for conduction abnormalities.

1 December 2018 in EP Europace
Verified
Journal Article
Closed access
JHJelle Himmelreich
Jelle Himmelreich
WLWim A M Lucassen
Wim A M Lucassen
MHMartijn Heugen
Martijn Heugen
PBPatrick M M Bossuyt
Patrick M M Bossuyt
HTHanno L Tan
Hanno L Tan
HWHenk C P M van Weert
Henk C P M van Weert
Premature atrial contractions (PACs) are a common cardiac phenomenon, traditionally considered to be of little clinical significance. Recent studies, however, suggest that PACs are associated with atrial fibrillation (AF), as well as ischaemic stroke, transient ischaemic attack, and mortality. This systematic review aims to investigate the association between PACs on standard electrocardiogram (ECG) as well as PAC-count on Holter monitor and future detection of AF, brain ischaemia, and all-cause mortality in patients without a history of AF. We searched PubMed, Embase (OVID), and Cochrane Database of Systematic Reviews from inception through 11 April 2018 and performed a systematic review and meta-analysis. We assessed risk of bias using a modified Quality In Prognosis Studies tool. The primary expression of associations in meta-analysis was the unadjusted hazard ratio (HR) using a random effects model. We identified 33 eligible studies including 198 876 patients from Western and East Asian populations with mean age ranging 52-76 years. Frequent PACs on 24-48 h Holter was associated with AF [HR 2.96, 95% confidence interval (CI) 2.33-3.76; 15 cohorts, n = 16 613], first stroke (HR 2.54, 95% CI 1.68-3.83; 3 cohorts, n = 1468), and all-cause mortality (HR 2.14, 95% CI 1.94-2.37; 6 cohorts, n = 7571). There was insufficient evidence to conclude that presence of ≥1 PAC on standard 12-lead ECG is associated with future AF detection. In older patients without a history of AF, frequent PACs on 24-48 h Holter are significantly associated with AF, first stroke, and mortality.

18 January 2021 in Open Heart
Verified
Journal Article
Open access
PDF file
JHJelle Himmelreich
Jelle Himmelreich
WLWim A M Lucassen
Wim A M Lucassen
RHRalf E Harskamp
Ralf E Harskamp
CAClaire Aussems
Claire Aussems
HWHenk C P M van Weert
Henk C P M van Weert
MNMark M J Nielen
Mark M J Nielen
Aims: To validate a multivariable risk prediction model (Cohorts for Heart and Aging Research in Genomic Epidemiology model for atrial fibrillation (CHARGE-AF)) for 5-year risk of atrial fibrillation (AF) in routinely collected primary care data and to assess CHARGE-AF’s potential for automated, low-cost selection of patients at high risk for AF based on routine primary care data.Methods: We included patients aged ≥40 years, free of AF and with complete CHARGE-AF variables at baseline, 1 January 2014, in a representative, nationwide routine primary care database in the Netherlands (Nivel-PCD). We validated CHARGE-AF for 5-year observed AF incidence using the C-statistic for discrimination, and calibration plot and stratified Kaplan-Meier plot for calibration. We compared CHARGE-AF with other predictors and assessed implications of using different CHARGE-AF cut-offs to select high-risk patients.Results: Among 111 475 patients free of AF and with complete CHARGE-AF variables at baseline (17.2% of all patients aged ≥40 years and free of AF), mean age was 65.5 years, and 53% were female. Complete CHARGE-AF cases were older and had higher AF incidence and cardiovascular comorbidity rate than incomplete cases. There were 5264 (4.7%) new AF cases during 5-year follow-up among complete cases. CHARGE-AF’s C-statistic for new AF was 0.74 (95% CI 0.73 to 0.74). The calibration plot showed slight risk underestimation in low-risk deciles and overestimation of absolute AF risk in those with highest predicted risk. The Kaplan-Meier plot with categories 5% predicted 5-year risk was highly accurate. CHARGE-AF outperformed CHA2DS2-VASc (Cardiac failure or dysfunction, Hypertension, Age >=75 [Doubled], Diabetes, Stroke [Doubled]-Vascular disease, Age 65-74, and Sex category [Female]) and age alone as predictors for AF. Dichotomisation at cut-offs of 2.5%, 5% and 10% baseline CHARGE-AF risk all showed merits for patient selection in AF screening efforts.Conclusion: In patients with complete baseline CHARGE-AF data through routine Dutch primary care, CHARGE-AF accurately assessed AF risk among older primary care patients, outperformed both CHA2DS2-VASc and age alone as predictors for AF and showed potential for automated, low-cost patient selection in AF screening.

27 February 2019 in BMJ Open
Verified
Journal Article
Open access
PDF file
RHRalf E Harskamp
Ralf E Harskamp
SLSimone C Laeven
Simone C Laeven
JHJelle Himmelreich
Jelle Himmelreich
WLWim A M Lucassen
Wim A M Lucassen
HWHenk C P M van Weert
Henk C P M van Weert
Objective To identify and assess the performance of clinical decision rules (CDR) for chest pain in general practice. Design Systematic review of diagnostic studies. Data sources Medline/Pubmed, Embase/Ovid, CINAHL/EBSCO and Google Scholar up to October 2018. Study selection Studies that assessed CDRs for intermittent-type chest pain and for rule out of acute coronary syndrome (ACS) applicable in general practice, thus not relying on advanced laboratory, computer or diagnostic testing. Review methods Reviewers identified studies, extracted data and assessed the quality of the evidence (using Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2)), independently and in duplicate. Results Eight studies comprising five CDRs met the inclusion criteria. Three CDRs are designed for rule out of coronary disease in intermittent-type chest pain (Gencer rule, Marburg Heart Score, INTERCHEST), and two for rule out of ACS (Grijseels rule, Bruins Slot rule). Studies that examined the Marburg Heart Score had the highest methodological quality with consistent sensitivity (86%–91%), specificity (61%–81%) and positive (23%–35%) and negative (97%–98%) predictive values (PPV and NPV). The diagnostic performance of Gencer (PPV: 20%–34%, NPV: 95%–99%) and INTERCHEST (PPV: 35%–43%, NPV: 96%–98%) appear comparable, but requires further validation. The Marburg Heart Score was more sensitive in detecting coronary disease than the clinical judgement of the general practitioner. The performance of CDRs that focused on rule out of ACS were: Grijseels rule (sensitivity: 91%, specificity: 37%, PPV: 57%, NPV: 82%) and Bruins Slot (sensitivity: 97%, specificity: 10%, PPV: 23%, NPV: 92%). Compared with clinical judgement, the Bruins Slot rule appeared to be safer than clinical judgement alone, but the study was limited in sample size. Conclusions In general practice, there is currently no clinical decision aid that can safely rule out ACS. For intermittent chest pain, several rules exist, of which the Marburg Heart Score has been most extensively tested and appears to outperform clinical judgement alone.

5 April 2023 in Cardiovascular Digital Health Journal
Verified
Journal Article
Open access
JHJelle Himmelreich
Jelle Himmelreich
RHRalf E. Harskamp
Ralf E. Harskamp
The use of 12-lead electrocardiogram (ECG) is common in routine primary care, however it can be difficult for less experienced ECG readers to adequately interpret the ECG. To validate a smartphone application (PMcardio) as a stand-alone interpretation tool for 12-lead ECG in primary care. We recruited consecutive patients who underwent 12-lead ECG as part of routinely indicated primary care in the Netherlands. All ECGs were assessed by the PMcardio app, which analyzes a photographed image of 12-lead ECG for automated interpretation, installed on an Android platform (Samsung Galaxy M31) and an iOS platform (iPhone SE2020). We validated the PMcardio app for detecting any major ECG abnormality (MEA, primary outcome), defined as atrial fibrillation/flutter (AF), markers of (past) myocardial ischemia, or clinically relevant impulse and/or conduction abnormalities; or AF (key secondary outcome) with a blinded expert panel as reference standard. We included 290 patients from 11 Dutch general practices with median age 67 (interquartile range 55–74) years; 48% were female. On reference ECG, 71 patients (25%) had MEA and 35 (12%) had AF. Sensitivity and specificity of PMcardio for MEA were 86% (95% CI: 76%–93%) and 92% (95% CI: 87%–95%), respectively. For AF, sensitivity and specificity were 97% (95% CI: 85%–100%) and 99% (95% CI: 97%–100%), respectively. Performance was comparable between Android and iOS platform (kappa = 0.95, 95% CI: 0.91–0.99 and kappa = 1.00, 95% CI: 1.00–1.00 for MEA and AF, respectively). A smartphone app developed to interpret 12-lead ECGs was found to have good diagnostic accuracy in a primary care setting for major ECG abnormalities, and near-perfect properties for diagnosing AF.