Yongping Lin

Yongping Lin


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 August 2022 in Frontiers in Physiology
Verified
Journal Article
Open access
WMWei Mao
Wei Mao
CCChunxia Chen
Chunxia Chen
HGHuachao Gao
Huachao Gao
LXLiu Xiong
Liu Xiong
YLYongping Lin
Yongping Lin
Early treatment increases the 5-year survival rate of patients with endometrial cancer (EC). Deep learning (DL) as a new computer-aided diagnosis method has been widely used in medical image processing which can reduce the misdiagnosis by radiologists. An automatic staging method based on DL for the early diagnosis of EC will benefit both radiologists and patients. To develop an effective and automatic prediction model for early EC diagnosis on magnetic resonance imaging (MRI) images, we retrospectively enrolled 117 patients (73 of stage IA, 44 of stage IB) with a pathological diagnosis of early EC confirmed by postoperative biopsy at our institution from 1 January 2018, to 31 December 2020. Axial T2-weighted image (T2WI), axial diffusion-weighted image (DWI) and sagittal T2WI images from 117 patients have been classified into stage IA and stage IB according to the patient’s pathological diagnosis. Firstly, a semantic segmentation model based on the U-net network is trained to segment the uterine region and the tumor region on the MRI images. Then, the area ratio of the tumor region to the uterine region (TUR) in the segmentation map is calculated. Finally, the receiver operating characteristic curves (ROCs) are plotted by the TUR and the results of the patient’s pathological diagnosis in the test set to find the optimal staging thresholds for stage IA and stage IB. In the test sets, the trained semantic segmentation model yields the average Dice similarity coefficients of uterus and tumor on axial T2WI, axial DWI, and sagittal T2WI were 0.958 and 0.917, 0.956 and 0.941, 0.972 and 0.910 respectively. With pathological diagnostic results as the gold standard, the classification model on axial T2WI, axial DWI, and sagittal T2WI yielded an area under the curve (AUC) of 0.86, 0.85 and 0.94, respectively. In this study, an automatic DL-based segmentation model combining the ROC analysis of TUR on MRI images presents an effective early EC staging method.

22 February 2023 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
WMWei Mao
Wei Mao
CCChunxia Chen
Chunxia Chen
HGHuachao Gao
Huachao Gao
LXLiu Xiong
Liu Xiong
YLYongping Lin
Yongping Lin

31 October 2023 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
LXLiu Xiong
Liu Xiong
CCChunxia Chen
Chunxia Chen
YLYongping Lin
Yongping Lin
WMWei Mao
Wei Mao
ZSZhiyu Song
Zhiyu Song
To classify early endometrial cancer (EC) on sagittal T2-weighted images (T2WI) by determining the depth of myometrial infiltration (MI) using a computer-aided diagnosis (CAD) method based on a multi-stage deep learning (DL) model. This study retrospectively investigated 154 patients with pathologically proven early EC at the institution between January 1, 2018, and December 31, 2020. Of these patients, 75 were in the International Federation of Gynecology and Obstetrics (FIGO) stage IA and 79 were in FIGO stage IB. An SSD-based detection model and an Attention U-net-based segmentation model were trained to select, crop, and segment magnetic resonance imaging (MRl) images. Then, an ellipse fitting algorithm was used to generate a uterine cavity line (UCL) to obtain MI depth for classification. In the independent test datasets, the uterus and tumor detection model achieves an average precision rate of 98.70% and 87.93%, respectively. Selecting the optimal MRI slices method yields an accuracy of 97.83%. The uterus and tumor segmentation model with mean IOU of 0.738 and 0.655, mean PA of 0.867 and 0.749, and mean DSC of 0.845 and 0.779, respectively. Finally, the CAD method based on the calculated MI depth reaches an accuracy of 86.9%, a sensitivity of 81.8%, and a specificity of 91.7% for early EC classification. In this study, the CAD method implements an end-to-end early EC classification and is found to be on par with radiologists in terms of performance. It is more intuitive and interpretable than previous DL-based CAD methods.

21 December 2020 in Journal of Innovative Optical Health Sciences
Verified
Journal Article
Open access
PDF file
YLYongping Lin
Yongping Lin
DLDezi Li
Dezi Li
WLWang Liu
Wang Liu
ZZZhaowei Zhong
Zhaowei Zhong
ZLZhifang Li
Zhifang Li
SWShulian Wu
Shulian Wu
In this study, we proposed a method to measure the epidermal thickness (ET) of skin based on deep convolutional neural network, which was used to determine the boundaries of skin surface and the ridge portion in dermal–epidermis junction (DEJ) in cross-section optical coherence tomography (OCT) images of fingertip skin. The ET was calculated based on the row difference between the surface and the ridge top, which is determined by search the local maxima of boundary of the ridge portion. The results demonstrated that the region of ridge portion in DEJ was well determined and the ET measurement in this work can reduce the effect of the papillae valley in DEJ by 9.85%. It can be used for quantitative characterization of skin to differentiate the skin diseases.

18 May 2021 in Optics Express
Verified
Journal Article
Closed access
ZZZhaowei Zhong
Zhaowei Zhong
JZJialing Zhang
Jialing Zhang
ZLZhifang Li
Zhifang Li
YLYongping Lin
Yongping Lin
SWShulian Wu
Shulian Wu
Optical coherence tomography (OCT) was used for imaging three-dimensional fingerprint to overcome the effects of different skin states and fake fingerprint. However, the OCT-based fingerprint features depend on the depth of fingertip skin which is still challenging for biometric recognition and encryption. In this work, we presented a new approach of maximum intensity projection (MIP) image of the epidermal-dermal junction (DEJ) to extract the internal fingerprint that is independent of the depth of fingertip skin. To begin with, the surface and DEJ were segmented based on the deep learning algorithm. Then the internal fingerprint was extracted by the MIP image of DEJ which has a more accurate structural similarity by quantitative analysis. The experimental results showed that internal fingerprint acquired by MIP of DEJ can be applied for scar-simulation fingertip and encryption since it is not sensitive to the states of surface skin and independent of the depth.

6 December 2023 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
JSJialin Su
Jialin Su
MLMeifang Li
Meifang Li
YLYongping Lin
Yongping Lin
LXLiu Xiong
Liu Xiong
CYCaixing Yuan
Caixing Yuan
KYKunlong Yan
Kunlong Yan
Background: Chest computed tomography (CT) image quality impacts radiologists’ diagnoses. Pre-diagnostic image quality assessment is essential but labor-intensive and may have human limitations (fatigue, perceptual biases, and cognitive biases). This study aims to develop and validate a deep learning (DL)-driven multi-view multi-task image quality assessment (M $$^2$$ 2 IQA) method for assessing the quality of chest CT images in patients, to determine if they are suitable for assessing the patient’s physical condition. Methods: This retrospective study utilizes and analyzes chest CT images from 327 patients. Among them, 1613 images from 286 patients are used for model training and validation, while the remaining 41 patients are reserved as an additional test set for conducting ablation studies, comparative studies, and observer studies. The M $$^2$$ 2 IQA method is driven by DL technology and employs a multi-view fusion strategy, which incorporates three scanning planes (coronal, axial, and sagittal). It assesses image quality for multiple tasks, including inspiration evaluation, position evaluation, radiation protection evaluation, and artifact evaluation. Four algorithms (pixel threshold, neural statistics, region measurement, and distance measurement) have been proposed, each tailored for specific evaluation tasks, with the aim of optimizing the evaluation performance of the M $$^2$$ 2 IQA method. Results: In the additional test set, the M $$^2$$ 2 IQA method achieved 87% precision, 93% sensitivity, 69% specificity, and a 0.90 F1-score. Extensive ablation and comparative studies have demonstrated the effectiveness of the proposed algorithms and the generalization performance of the proposed method across various assessment tasks. Conclusion: This study develops and validates a DL-driven M $$^2$$ 2 IQA method, complemented by four proposed algorithms. It holds great promise in automating the assessment of chest CT image quality. The performance of this method, as well as the effectiveness of the four algorithms, is demonstrated on an additional test set.